Presentation is loading. Please wait.

Presentation is loading. Please wait.

General remarks about the HESR and PANDA vacuum system

Similar presentations


Presentation on theme: "General remarks about the HESR and PANDA vacuum system"— Presentation transcript:

1 General remarks about the HESR and PANDA vacuum system
04. February Dieter Prasuhn

2 Vacuum System for the HESR @ FAIR Design parameters
Total average pressure better than 1 x 10-9 mbar at room temperature. 22 sections (incl. 2 for E-Cooler, 1 for PANDA) Section length range between 6 m and 45 m, max. volume of 280 l. All vacuum chambers made from AISI 316 LN stainless steel with low hydrogen content and low permeability. On advice of the MAC 2010: NEG pumping system and baking is planned.

3 Vacuum sections in the HESR
15/16 E-COOLER (33/-) 18 Dipol23 (23/144) 17 Quad (40/249) 14 Quad (34/210) 13 Kicker (9/-) 12 Dipol22 (20/127) Boundary of E-Cooler hall 19 Dipol24 (45/280) 11 Dipol15 (45/280) 20 Dipol31 (41/254) Vacuum chamber diameter: 89 mm around the ring, Exception: PANDA section 10 Dipol09 (41/254) (100/150) vacuum section valve length[m]/volume[l] 21 Dipol37 (45/280) ( . / .) 09 Dipol02 (45/280) 22 Dipol44 (26/161) 07 Septum (17+6/140) 08 Dipol01 (27/166) 01 SEPTUM (21+6/170) 02 RF (7/-) Boundary of PANDA hall 05 Quad (19/116) 06 PickUP (6/-) HR09MH02 03 ANTISOL (22/138) 04 PANDA (15/92)

4 Further Requirements The HESR vacuum chamber is designed smooth with an inner diameter of 89 mm all around the ring All feedthroughs and pumping stations are equipped with RF grids

5 Vacuum System for the HESR @ FAIR pumping body for the arcs
140 pieces in three variations (2 x arc, 1 x straights)

6 Beam diameter changes q < 35°

7 The PANDA region

8 The PANDA section with magnets and detectors
Slide Valve HR04VVT01 Slide Valve HR05VVT01 3 m 11.8 m Pumping Body HR03VR014 Pumping Body HR05VR003 6.7 m 13.3 m SC Antisol PANDA PANDA chicane Dipol

9 The vacuum system in the PANDA section
Pellet or cluster beam p-bar beam

10

11 Target cross Ti, wall thickness 0.2 mm inner diameter 20.0 mm
outer diameter 20.4 mm

12 Target pipe Ti, wall thickness 0.2 mm inner diameter 20.0 mm
outer diameter 20.4 mm Ti, wall thickness 0.3 mm inner diameter 40.0 mm outer diameter 40.6 mm

13 The bayonet junction Torque = 100 N cm

14 HESR beam pipe Ti, wall thickness 0.2 mm inner diameter 20.0 mm
outer diameter 20.4 mm Ti, wall thickness 0.3 mm inner diameter 40.0 mm outer diameter 40.6 mm

15 The Cone Ti, wall thickness 0.5 mm small diameter 20.0 mm
large diameter mm length mm

16 Some Questions by Herbert Orth:
Types of flanges and sealings in the HESR: CF flanges, all metal sealed RF requirements: RF grids in the pumping crosses Transitions with an angle less than 35° Valves with RF bridges High quality weldings do not disturb the RF