EN Division-Metallurgy and Metrology Domaine / Field: CLIC Date: 22/09/2015 N° EDMS / EDMS Nr.: draft Requérant / Customer: Walter Wuensch Liste de distribution / Distribution list: RF development mmeting DC electrodes comparison Soft Cu Vs Hard Cu Données expérimentales / Experimental data: Sample: 4 electrodes from the DC system. Two of them overpass the Heat Treatment and thus are in a hard Cu state. The other two are in their more standard, for this kind of samples, soft Cu state. Equipment : Optical Microscope Zeiss Axio-Imager, with ZenCore2 and Axio-Visio software. 50 mm2 X Max Energy-dispersive X-ray spectroscopy (EDS) detector (Oxford), INCA software. Redaction / Written by: E. RODRIGUEZ CASTRO – BE/RF-LRF Approuvé par / Accepted by: F. LEAUX - EN/MME-MM Expériences / Testing by: Superviseur / Supervisor: EN Division-Materials and Metrology CERN/EN/MME-MM/EDMS draft
2
Introduction: Individual observation reports are available:
For soft Cu (EDMS v.1) For hard Cu (EDMS v.1)
3
Soft Cu electrodes Anode n16 Cathode n14 Cathode image is mirroed
4
Hard Cu electrodes Anode hard Cu Cathode hard Cu
Cathode image is mirroed
5
Summary of observations
In Soft Cu electrodes the BD craters are spread all over the surfaces In Hard Cu electrodes the BD craters are clustered in several positions