Presentation is loading. Please wait.

Presentation is loading. Please wait.

Date of download: 10/24/2017 Copyright © ASME. All rights reserved.

Similar presentations


Presentation on theme: "Date of download: 10/24/2017 Copyright © ASME. All rights reserved."— Presentation transcript:

1 Date of download: 10/24/2017 Copyright © ASME. All rights reserved. From: A Reexamination of Phonon Transport Through a Nanoscale Point Contact in Vacuum J. Heat Transfer. 2013;136(3): doi: / Figure Legend: Ballistic thermal conductance contributions from the four lowest phonon polarizations with ωmin = 0 of a square Si nanowire with a 2 × 2 nm2 cross section [32] (solid line), shown in comparison with 4G0 (dotted line). Also shown is the ballistic thermal conductance of the three acoustic phonon 1D subbands (dash-dotted line) and of the three acoustic and three optical phonon 1D subbands (dash-dot-dot line) of bulk silicon in the Γ–X [or (100)] direction [29], the thermal conductance between a 1D silicon-like monatomic chain with 3 degrees of freedom and a 3D semi-infinite silicon-like contact [23] (thin dash-dot-dot line), shown in comparison with 3G0. Additionally, the ballistic thermal conductance for the longitudinal acoustic branch of a model 1D system constructed of an infinitely long chain of silicon atoms assuming bulk elastic constants [25] (thin dotted line), shown in comparison with G0 (thin solid line).

2 Date of download: 10/24/2017 Copyright © ASME. All rights reserved. From: A Reexamination of Phonon Transport Through a Nanoscale Point Contact in Vacuum J. Heat Transfer. 2013;136(3): doi: / Figure Legend: False color scanning electron micrographs of the AFM cantilever preparation procedure showing (a) the commercial cantilever, (b) local removal of Ti/Au using a focused Ga+ ion beam and (c) local ion beam induced metal deposition of a Pt–C resistance thermometer. The Si tip is located on the opposite side of the cantilever. Scale bars are 50 μm. (d) Electrical resistance (R) versus temperature for the Pt–C resistance thermometer.

3 Date of download: 10/24/2017 Copyright © ASME. All rights reserved. From: A Reexamination of Phonon Transport Through a Nanoscale Point Contact in Vacuum J. Heat Transfer. 2013;136(3): doi: / Figure Legend: (a) Change in dc voltage of the Pt-C resistance thermometer, Vdc, versus applied dc current, Idc, when the cantilever is out-of-contact with the substrate. (b) Corresponding change in electrical resistance, R, versus Idc determined by the measured Vdc/Idc (circles) and by fitting Vdc(Idc) with a third order polynomial, Vdc(Idc) = a3Idc3 + a2Idc2 + a1Idc + a0, and dividing Vdc(Idc) –a0 by Idc (solid line). (c) The heating induced resistance change (ΔR) plotted as a function of χ≡dRPt-C/dT(Qh+12Qb)+dRAu/dT(12Qh+13Qb). (d) The corresponding change in temperature of the Pt–C RT, ΔTh, as a function of the total Joule heat dissipation, Q = Qh + Qb.

4 Date of download: 10/24/2017 Copyright © ASME. All rights reserved. From: A Reexamination of Phonon Transport Through a Nanoscale Point Contact in Vacuum J. Heat Transfer. 2013;136(3): doi: / Figure Legend: Schematic diagram and thermal resistance circuit of the experimental method for in-contact thermal resistance measurement of a Si–Si nanopoint contact

5 Date of download: 10/24/2017 Copyright © ASME. All rights reserved. From: A Reexamination of Phonon Transport Through a Nanoscale Point Contact in Vacuum J. Heat Transfer. 2013;136(3): doi: / Figure Legend: Measured change in electrical resistance of the Pt–C RT, ΔR, when heated by a dc current and measured by a coupled ac current of frequency f, normalized by the change measured using a frequency of f = 15 kHz

6 Date of download: 10/24/2017 Copyright © ASME. All rights reserved. From: A Reexamination of Phonon Transport Through a Nanoscale Point Contact in Vacuum J. Heat Transfer. 2013;136(3): doi: / Figure Legend: Concurrently measured (a) temperature rise at the cantilever tip, ΔTh, and (b) intensity reading of the position sensitive quadrant-cell detector, IPSD, plotted as a function of laser power set point, Plaser/Plaser,max, where Plaser,max < 7 mW. The laser beam position was adjusted to maximize IPSD for each laser power set point. As can be typical with scanning probe microscopes, the emitted laser power is not a linear function of the set point for small set point values. The laser power set point used to measure cantilever deflection in this experiment is 17% and hence induces a negligible ΔTh.

7 Date of download: 10/24/2017 Copyright © ASME. All rights reserved. From: A Reexamination of Phonon Transport Through a Nanoscale Point Contact in Vacuum J. Heat Transfer. 2013;136(3): doi: / Figure Legend: (a) Normal force, FN, and (b) electrical resistance change normalized by out-of-contact electrical resistance, ΔR/R, plotted versus vertical height above the Si substrate, z. Data measured during approach (retract) are shown in filled (open) symbols for fixed a heating powers of 53.4 μW, corresponding to an out-of-contact temperature rises of 33 K above room temperature.

8 Date of download: 10/24/2017 Copyright © ASME. All rights reserved. From: A Reexamination of Phonon Transport Through a Nanoscale Point Contact in Vacuum J. Heat Transfer. 2013;136(3): doi: / Figure Legend: Sudden electrical resistance change of the Pt–C resistance thermometer when the Si tip is brought into contact with the Si substrate, ΔRcontact = Rin-contact – Rout-of-contact, plotted versus total heating power, Q, measured at the snap-to and pull-off contact points over several approach/retract cycles. The applied Q corresponds to out-of-contact temperature rises of ΔTh = 22–33 K above room temperature. Additionally, ΔRcontact extrapolates to 0.2 Ω at Q = 0.

9 Date of download: 10/24/2017 Copyright © ASME. All rights reserved. From: A Reexamination of Phonon Transport Through a Nanoscale Point Contact in Vacuum J. Heat Transfer. 2013;136(3): doi: / Figure Legend: (a) Front and (b) side profile scanning electron micrographs of the cantilever tip taken post-measurement. Dashed lines in (b) denote the plane of the substrate with respect to the cantilever tip. High resolution SEM images of the front and side tip profiles are displayed in the insets of (a) and (b), respectively. For the case that the tip makes contact with the flattened portion along its frontal slope, the maximum effective contact area can be described by an ellipse with major diameter d1 and minor diameter d2 shown in the two insets Scale bars are 1 μm for ((a) and (b)) and 50 nm for ((a), inset and (b), inset).

10 Date of download: 10/24/2017 Copyright © ASME. All rights reserved. From: A Reexamination of Phonon Transport Through a Nanoscale Point Contact in Vacuum J. Heat Transfer. 2013;136(3): doi: / Figure Legend: Schematic showing (a) top view and (b) side view cantilever geometry


Download ppt "Date of download: 10/24/2017 Copyright © ASME. All rights reserved."

Similar presentations


Ads by Google