Download presentation
Presentation is loading. Please wait.
Published byMavis Cain Modified over 6 years ago
1
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Room Master, Basic, RM/S 1.1
2CDC N0201 | Slide 1
2
New Innovation Room Master
Innovation features Room Scenarios Recall with one group-address All function in the room (e.g. lighting, fan coil, sockets and thermostat) are setting Recall internal (e.g. binary inputs) Recall external (e.g. reception) Device connection internal between in- and outputs without group-address © ABB STOTZ-KONTAKT GmbH 2CDC N0201 | Slide 2
3
Second Step - Overview Room: Commands
External commands from the Reception Check In – Room occupied Check Out – Room vacant Standby – Room free for Servicing Device internal commands from the binary inputs Keycard on the entrance Emergency call in the bathroom Room internal commands (via bus) Sensor inputs switch device outputs Change the operating mode of the Room Thermostat (RT) Integration of further KNX-devices © ABB STOTZ-KONTAKT GmbH 2CDC N0201 | Slide 3
4
Room Scenario Overview
Altogether 10 Room Scenario are configurable Room Scenario are grouped in pairs Keycard move Keycard remove Each Room Scenario can be activated on receipt of an externally 1 byte telegram or device internally via a binary input can control up to 7 communication objects these controls can be used to control the Room Master itself, external KNX-device in the room or in the building, e.g. the reception © ABB STOTZ-KONTAKT GmbH 2CDC N0201 | Slide 4
5
Room Scenario (RS) Allocation (Default settings)
RS 1 Check In RS 2 Check Out RS 3 Standby RS 4 Emergency Call RS 5 Keycard remove RS 6 Keycard move RS 7 free RS 8 free RS 9 free RS 10 free All Room Scenario are freely configurable © ABB STOTZ-KONTAKT GmbH 2CDC N0201 | Slide 5
6
Room Scenario Overview: Events
A Room Scenario consists of two control events one can be sent immediately other can be sent immediately or with a delay Per control event it can configured whether a KNX Scene is trigged internally or via the bus two 1 bit values are sent the Room Temperature is switched on/off a certain operation mode in the Room Thermostat is set the automatic function for the shutters is activated the internal blocking of the inputs is activated © ABB STOTZ-KONTAKT GmbH 2CDC N0201 | Slide 6
7
Room Scenario KNX Scene
On activation of a Room Scenario via a only KNX Scene This has clear advantages: Simple integration of further sensors and actors in the room Clear separation to other rooms by use of one “room-group address” No unnecessary bus load by internal Room Scenario (internal used) Flexible configuration of the functionality © ABB STOTZ-KONTAKT GmbH 2CDC N0201 | Slide 7
8
Room Scenario How does it work?
Consumer Commands - internal control - direct connection - via bus Fan Coil KNX Sensor Inputs Room Thermostat Reception © ABB STOTZ-KONTAKT GmbH 2CDC N0201 | Slide 8
9
Floor plan Complete Hotel Room (1 ½ Room) TV Content area
© ABB STOTZ-KONTAKT GmbH 2CDC N0201 | Slide 9
10
Check In – Room occupied Reception activates Room Scenario 1
Sockets switch on Room Thermostat change the operating mode to Comfort specified inputs are blocked Commands - internal control - direct connection - via bus TV Content area © ABB STOTZ-KONTAKT GmbH 2CDC N0201 | Slide 10
11
Check Out – Room vacant Reception activates Room scenario 2
lights and sockets switch off complete Room Thermostat change the operating mode to Standby specified inputs are blocked Commands - internal control - direct connection - via bus TV Content area © ABB STOTZ-KONTAKT GmbH 2CDC N0201 | Slide 11
12
Standby – Room free for Servicing Reception activates Room scenario 3
lights and sockets switch off complete Room Thermostat switch off and change the operating mode to Building protection Commands - internal control - direct connection - via bus TV Content area © ABB STOTZ-KONTAKT GmbH 2CDC N0201 | Slide 12
13
Emergency call operates Emergency call activates Room scenario 4
lights switch on complete message to the reception Commands - internal control - direct connection - via bus TV Content area © ABB STOTZ-KONTAKT GmbH 2CDC N0201 | Slide 13
14
Keycard remove Keycard activates room condition 5
Complete lights switch off with a delay, sockets immediately change Room Thermostat the operating mode to Building protection specified inputs are blocked Commands - internal control - direct connection - via bus TV Content area © ABB STOTZ-KONTAKT GmbH 2CDC N0201 | Slide 14
15
Keycard move Keycard activates room condition 6
Complete lights and sockets switch on Room Thermostat change the operating mode to Comfort specified inputs are enable Commands - internal control - direct connection - via bus TV Content area © ABB STOTZ-KONTAKT GmbH 2CDC N0201 | Slide 15
16
Fan Coil-Unit Window Contact / Drip Tray
connect window contact via group address to the Room Thermostat connect drip tray via group address to the Room Thermostat Commands - internal control - direct connection - via bus © ABB STOTZ-KONTAKT GmbH 2CDC N0201 | Slide 16
17
Summary Room Master New innovation features
Room Scenario intern/extern Internal connection between in- and outputs Highly flexible compatible Room Thermostat RDF/A problem free integrated further KNX devices No external auxiliary supply voltage required By the innovation of special default settings the basic features are functional in the room unpack connect finish © ABB STOTZ-KONTAKT GmbH 2CDC N0201 | Slide 17
18
© ABB STOTZ-KONTAKT GmbH
2CDC N0201 | Slide 18
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.