Download presentation
Presentation is loading. Please wait.
Published byGwen Palmer Modified over 6 years ago
1
BATTERY PERFORMANCE METER FOR ELECTRIC PROPULSION SYSTEMS
Team Members: Ryan Bickham, Dennis Blosser Cody Dinkins, Todd Dutton, Rachel Shively Project Sponsor: Patrick Taylor, Ph.D., AMRDEC February 26, 2008
2
Received: Tektronix CPS250 Power Supply
Voltage outputs: One 5.0 VDC - Two 0 to 20 VDC Line regulation: - 0.01% +/- 3 mV
3
Motor-Dynamometer Tolerance Analysis
Dynamometer accuracy is between +/-0.3% and +/-0.5% Dyno max power output is 3000 W Dyno accuracy within 15 W Estimated motor power is W or hp For a 12 min run time If power accuracy is within 15 W then the motor power accuracy will be +/-12.3%
4
Motor Mount Sample Drawing
5
NI Virtual Instrumentation Block Diagram
6
NI Virtual Instrumentation GUI
7
Sample Filtering - Each signal coming into the SCXI-1102B must be filtered by a simple RC lowpass filter. - From provided documentation: - Choose fs = 512 samples/sec - fc = 165 Hz Simple Resistor/Capacitor calculation: RC = → Choose R = 1 kΩ C = 1 µF
8
Procurement List - SCXI-1000 Filler Panels
- SCXI-1360 Front Filler Panel, Quantity: 2 - SCXI-1361 Rear Filler Panel, Quantity: Available in orders of 5-10, $15/order - EC3 Battery Connector Extension, Quantity: 4 – 5, Price: $6 each
13
12 VDC
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.