1 Andrei Shishlo ORNL SNS Project Florence, Italy November 2015
Using Stripline BPMs to Measure the Longitudinal Twiss Parameters in the SNS linac Andrei Shishlo ORNL SNS Project Florence, Italy November 2015

2 Outline Physics picture description Harmonics analysis
Short RF cavity +drift+ BPM Algorithm SNS Results Conclusions

3 Longitudinal Bunch Distribution from Stripline BPMs. Is it possible?
signal 2R r0 If v=c the signal will be proportional to ρ(z) Our case v<c and r0 <<R There is now direct way to interpret the stripline BPM signal as the bunch density Bunch usually too short for the frequency bandwidth of the existing electronics No, it is not possible! What can we do? signal From Alex Chao’s book “Collective Instabilities in Accelerators”

4 Amplitude of Particular Harmonic
J. H. Cuperus, Nucl. Instrum. Methods 145, 219 (1977) MONITORING OF PARTICLE BEAMS AT HIGH FREQUENCIES - Harmonics of sum of electrodes BPMs signal at frequency - Fourier harmonics of the longitudinal density distribution - radius of the beam pipe - relativistic parameters Citation: “The response to higher harmonics is limited, and measurement of the bunch form is not possible.” We are not going to use the higher harmonics Let’s assume this for easy interpretation

5 Harmonic of Gaussian Distribution
Gaussian Longitudinal Distribution BPM harmonic after Fourier transformation - Longitudinal bunch size in deg. Problem: for short bunches results are useless For long bunches BPM is an analog of a Wire Scanner for the longitudinal size

6 SNS H- linac SNS Linac Structure
Length: 330 m (Superconducting part 230 m) Production parameters: Peak current: 38 mA Repetition rate: 60 Hz Macro-pulse length: 1 ms Final Energy: 940 MeV (1000 MeV design) Average power: 1.4 MW Important for us Linac Diagnostics: BPM - Beam Position and Phase Monitors

7 Longitudinal Twiss Analysis
CCL4 BPM1 BPM2 BPM{n} Standard LSM Problem n – number of BPMs or we can do n measurements with one BPM

8 SCL Entrance Longitudinal Twiss Analysis
CCL4 BPM1 BPM2 BPM{n} All SCL RF are OFF Statistics: 40 measurements 13 BPMs Does not work! Errors are too big!

9 RF Cavity as Measuring Device
SCL RF CCL4 BPM1 BPM2 BPM{n} dE dE dE φ φ φ Drifting RF Kick σφ Maximal debunching RF transforms longitudinal phases space We have good models for short RF cavities The RF transport matrix is known Over-focusing in RF z RF cavity position

10 Longitudinal Twiss Analysis with SCL RF
CCL4 BPM1 BPM2 BPM{n} We can include a controllable element in the lattice and get more data The Twiss errors should be reduced. For 5 deg step, matrix will be (72x14)x3. Results (XAL units): Alpha = Beta = Emitt = ( )*10-6 A. Shishlo, A. Aleksandrov, Phys. ST Accel. and Beams 16, (2013). Over focusing Defocusing

11 SCL Twiss for CCL4 Phase Scan
BSM SCL RF CCL4 BPM1 BPM2 BPM{n} CCL4 Phase Scan -20 ↔ +40 deg Design phase = 0 deg SCL01a Phase Scan For Long. Twiss We want to verify our method with something different Studies performed on Simultaneous BSM-410 measurements Peak beam current 35 mA

12 CCL Bunch Length for Two Methods
Design Results are very close. It proves the applicability of the new method. Limitations: assumption of Gaussian distribution in the bunch. If we are far from the matched case (design) the bunch could be non Gaussian.

13 Longitudinal Twiss along SCL (1)
RF 01a SCL RF 01b SCL RF 01c SCL RF 02a SCL RF 02b SCL RF 02c BPM1 BPM2 BPM{n} We can use each cavity in SCL as the measuring point for the longitudinal Twiss Data were collected in April, 2013 Only cavities in the first 12 cryomodules were scanned (34 cavities) The BPM amplitude calibration was calculated by using the same scan data, so only about half of BPMs were calibrated properly. For the first cavity we used the analysis described, but for all downstream cavities we assumed a constant normalized emittance. It means we fitted α, β Twiss parameters only and un-normalized BPM amplitudes.

14 Longitudinal Twiss along SCL (2)
We have measurements at the entrance of each cavity, and we can calculate Twiss by using Online Model and the initial Twiss Results are in a good agreement The existing discrepancies grow with the distance from the beginning. Probably OM is not very good for very unmatched beams. In longitudinal direction we have a very unmatched beam. The matching will be done in the future.

15 Results of “Z” Twiss Analysis 2014
Longitudinal beam size Peak current 24 mA Production beam Beam un-matched longitudinally Agreement Model/Measurements is good.

16 Conclusions A non-invasive method of measurements of Longitudinal Twiss parameters with stripline BPMs is developed The method was validated on SNS SCL linac

17 Latest Attempt J-PARC

18 J-PARC BPMs’ Signals BPM’s Length bunch T Beam t t T
Signal from A end t T Signal from B end Signal from the B-end is late because it takes time for the bunch to reach this end and time for signal to go back.

19 Bunch Length and Amplitude of Harmonic
- constant defined by the BPM geometry - total bunch charge - RMS bunch length (*) Formulas (1) and (2) give us the ability to calculate the RMS bunch length if we know the Const and have the BPM waveform. It means we need a calibration!

20 J-PARC BPM ACS21B:BPM Signals
All ACS Cavities are OFF All ACS Cavities are ON J-PARC BPMs’ show the energy dependency in the peak positions It is not exactly an expected time shift: probably termination is not perfect Correction factors are needed