Presentation is loading. Please wait.

Presentation is loading. Please wait.

Date of download: 10/26/2017 Copyright © ASME. All rights reserved.

Similar presentations


Presentation on theme: "Date of download: 10/26/2017 Copyright © ASME. All rights reserved."— Presentation transcript:

1 Date of download: 10/26/2017 Copyright © ASME. All rights reserved. From: Assessment of the Ocular Response Analyzer as a Tool for Intraocular Pressure Measurement J Biomech Eng. 2009;131(8): doi: / Figure Legend: Overall views of a numerical model with 6 layers and 20 rings; (a) view from the anterior side, (b) view from the posterior side showing also model layers, and (c) cross-sectional view showing variable corneal thickness from minimum at center to maximum at periphery

2 Date of download: 10/26/2017 Copyright © ASME. All rights reserved. From: Assessment of the Ocular Response Analyzer as a Tool for Intraocular Pressure Measurement J Biomech Eng. 2009;131(8): doi: / Figure Legend: Air pressure distribution as applied by the ORA on the cornea’s anterior surface

3 Date of download: 10/26/2017 Copyright © ASME. All rights reserved. From: Assessment of the Ocular Response Analyzer as a Tool for Intraocular Pressure Measurement J Biomech Eng. 2009;131(8): doi: / Figure Legend: The relationships between ΔP1 and Δtrue IOP (IOPT) as obtained from numerical simulations for corneas with age between: (a) 50 and 64 years, (b) 65 and 79 years, and (c) 80 and 95 years. The solid lines represent the results of linear regression analysis of clinical data for subjects aged 50–64.9 years and 65–79.9 years.

4 Date of download: 10/26/2017 Copyright © ASME. All rights reserved. From: Assessment of the Ocular Response Analyzer as a Tool for Intraocular Pressure Measurement J Biomech Eng. 2009;131(8): doi: / Figure Legend: Strength of association between the corneal factor, CF, and IOP for a range of k between 0 and 2

5 Date of download: 10/26/2017 Copyright © ASME. All rights reserved. From: Assessment of the Ocular Response Analyzer as a Tool for Intraocular Pressure Measurement J Biomech Eng. 2009;131(8): doi: / Figure Legend: Variation of ORA IOP and GAT IOP with the CCT, as obtained from the analysis of a clinical data set while (a) excluding subjects outside the 50–95 year age range, and (b) including all subjects

6 Date of download: 10/26/2017 Copyright © ASME. All rights reserved. From: Assessment of the Ocular Response Analyzer as a Tool for Intraocular Pressure Measurement J Biomech Eng. 2009;131(8): doi: / Figure Legend: Variation of ORA IOP and GAT IOP with age as obtained from the analysis of a clinical data set while (a) excluding subjects outside the 50–95 year age range, and (b) including all subjects


Download ppt "Date of download: 10/26/2017 Copyright © ASME. All rights reserved."

Similar presentations


Ads by Google