Presentation is loading. Please wait.

Presentation is loading. Please wait.

Gable Roof BCGCA3007B.

Similar presentations


Presentation on theme: "Gable Roof BCGCA3007B."— Presentation transcript:

1 Gable Roof BCGCA3007B

2 Gable Roof Flush with no eaves Flush with raked eaves Boxed

3 Flush Gable (No Eaves) Rafter finishes in line with end wall
Barge fixed to outside wall No Overhang Studwork to take sheeting or support brickwork Not required to support roof

4 Flush Gable with Raked Eaves
Ridge Extends to Form Eave Verge Trimmers to Support Gable Rafter Trimmers to Support Verge Trims and Roof Battens Gable Stud supports Second Rafter Brick Work or Wall Lining Second Rafter to Support Verge Trims Roof Extends to Form eave Top Plate may be extended to support Rafter

5 Boxed Gable Verge Rafter Gable Studs & Sheeting
Purlin & Lintel Extended to Support Verge Rafter Minimum Back span 2 x Overhang Design 3 x Overhang Base of Gable Lined & Level with U/S of Eaves

6 Verges Is the Junction of the Roof and the Barge/Verge Board
Verge Detail for Tiled Roof

7 Verge Detail for Tiled Roof

8 Principles of Roofing Ridges are Level Rafters run at 90
Hips & Valleys bisect all internal & external Corners Roof members are set out along centrelines

9 Roofing Members Ridge Common Rafter Collar Tie Top Plate Hanging Beam
Purlin Top Plate Strutting Beam Strut Ceiling Joist Strut

10 Roof Members Common Rafter – Main Sloping Roof Member
Spacing 450mm or 600mm for Tiled Roofs 900mm for tiled roofs Supports Roof Battens which in turn support roof coverings Must be in single lengths or joined over supports Fixings 2 x 75mm Skew & 2 x 75mm into Ceiling Joist (if joist is > 38, 90mm Nails)

11 Roofing Members Ridge Common Rafter Collar Tie Top Plate Hanging Beam
Purlin Top Plate Strutting Beam Strut Ceiling Joist Strut

12 Ridge Highest Part of the Roof Will run full length of Gable Roof
Runs Parallel to TOP PLATE Fixes Rafters at Top of Roof Rafters are nailed either side and not offset by more than 1 thickness In Uncoupled Roof, they act as beams Nailed to Rafters with 2 x 75mm Nails

13 Joining RidgeBoards

14 Roofing Members Ridge Common Rafter Collar Tie Top Plate Hanging Beam
Purlin Top Plate Strutting Beam Strut Ceiling Joist Strut

15 Purlin Also known as Underpurlin Fixed to Underside of RAFTER
Runs parallel to ridge and wall plates Reduce span of RAFTER Will run full length of Gable Roof

16

17 Roofing Members Ridge Common Rafter Collar Tie Top Plate Hanging Beam
Purlin Top Plate Strutting Beam Strut Ceiling Joist Strut

18 Struts Transfer Loads to Load Bearing Walls

19

20

21

22

23 Roofing Members Ridge Common Rafter Collar Tie Top Plate Hanging Beam
Purlin Top Plate Strutting Beam Strut Ceiling Joist Strut

24 Collar Ties

25 Common Rafter Principles
Birdsmouth Max 1/3 Depth of Rafter

26 Common Rafter Principles
Span – From Birdsmouth to Birdsmouth Half Span – From Birdsmouth to Centre

27 Common Rafter Principles
True Rise –From Horizontal line that passes thru the Intersection of Birdsmouth Plumb Line &Top of Rafter To : vertically plumb up to the Apex NOTE – True Rise is not measured from TOP PLATE

28 A Closer Look Top Of Rafter Birds Mouth Top Plate Ceiling Joist
NOTE – True Rise is not measured from TOP PLATE

29 Common Rafter Principles
If Rise is taken from Top Plate to Apex pitch will be incorrect

30 Common Rafter Principles
Pitching Line x-y line

31 Common Rafter Principles
Measured to edge of Ridge Measured to centre of Ridge

32 Common Rafter Principles
Centre Line Length True Length True Length is usually what we need

33 Determine Rafter Length Mathematically
Determine Span = 2700mm Determine Half Span = 2700/2 = 1350mm Determine Rafter Run = 1350- Half Ridge Thickness = 19/2 = 9.5 Rafter Run = True Length Rafter = / Cos 25 = 1480 Rafter 90 x 45 Ridge 125 x 19

34 Overhang Plan always from external wall

35 Determine Rafter Length Mathematically
In this case Timber Famed Wall O/H = 450 / cos 25 = 497mm Roofing calculations are always measured from Birdsmouth or pitching point Rafter 90 x 45 Ridge 125 x 19

36 Determine Rafter Length Mathematically
In this case Brick Veneer Wall O/H = cos 25 = 662mm Total Rafter Length Timber Frame = = 1977mm Brick Veneer = = 2142mm Rafter 90 x 45 Ridge 125 x 19

37 Determine Rafter Length Graphically
Draw Roof Full-size Measure members directly Avoid using scaled drawing Scale use only for angles Rafter 90 x 45 Ridge 125 x 19

38 Determine Rafter Length Using Roofing Square
Use Calculator Press Tan 25 – what does this give you Therefore for every 1 metre run there is 0.466m rise Using the principle of similar triangles we half the size of the triangle

39 Press Tan 25 – what does this give you
Use Calculator Press Tan 25 – what does this give you Therefore for every 1 metre run there is 0.466m rise Using the principle of similar triangles we half the size of the triangle

40 Press Tan 25 – what does this give you
Use Calculator Press Tan 25 – what does this give you Therefore for every 1 metre run there is 0.466m rise Using the principle of similar triangles we half the size of the triangle

41 Using Similar Triangles
1341/500 = or = 2 r 341

42 Using Similar Triangles 1341/500 = 2.682 or = 2 r 341
Step out 2 full triangles Select Start Point Allowing for O/H

43 Intersection of Top of Rafter & Edge of Square

44 Using Similar Triangles 1341/500 = 2.682 or = 2 r 341
Step out 341 & use square to extend Step out 2 full triangles Select Start Point Allowing for O/H

45 Determine Roofing Angles used in Gable Roofs
Plumb Cut Foot Cut

46 Determining Angles with Roofing Square
When we set out rafter previously we determined plumb cut

47 Determining Angles with Roofing Square
Plumb Cut Foot Cut

48 Determining Angles Mathematically
Extend Line 90⁰ From Rafter

49 Determining Angles Mathematically
Extend Line 90⁰ From Rafter Extend Plumb Line

50 Determining Angles Mathematically
Extend Line 90⁰ From Rafter Extend Plumb Line Angle Formed is same as roof pitch

51 Determining Angles Mathematically
Extend Line 90⁰ From Rafter Extend Plumb Line Angle Formed is same as roof pitch Offset = Tan (pitch) x width

52 Determining Angles Mathematically
Extend Line 90⁰ From Rafter Extend Plumb Line Angle Formed is same as roof pitch Offset = Tan (25⁰) x = 42

53 Determining Angles Mathematically
Next we can Determine our Birdsmouth Width across plumb cut = 90/ cos 25 = 99 Therefore max Birdsmouth = 33 Distance from top plate to top of Rafter = 66

54 Complete Q5 in Workbook

55 Determine Roof Angles Graphically
Plan – View We can only see rafter run

56 Determine Roof Angles Graphically
Extend Top Plate & Ridge

57 Determine Roof Angles Graphically
Extend Top Plate & Ridge Mark Rise

58 Determine Roof Angles Graphically
Plumb Cut Extend Top Plate & Ridge Mark Rise Draw Hypotenuse Foot Cut


Download ppt "Gable Roof BCGCA3007B."