Distributor Presentation Distribution Automation (DA) Michael Logue
2
FlexNet Water Solutions Platform
3
SCADA Solution Overview
DA / SCADA Jerrod Gas & Electric AMI Integration via their ESB strategy using MultiSpeak Water AMI Distribution Automation Volt/VAR Control Load Control Streetlight Control Gas Cathodic Protection Gas Pressure Monitoring Sonix v2 (and RGS) RTM II
4
MultiSmart Controllers
RTM II to MultiTrode MultiSmart VTScada MultiSmart Controllers 4
5
Example Lift Station
6
Example T866 Pressure monitor
7
Other Example Lift Stations Controls
8
Water SCADA Applications
Installations outside of the water/wastewater treatment plants Pump Station / Reservoir Pressure Monitoring and Management DMA (District Metering Area) Leak Detection Lift Stations TC866 MircoRTU HydroRanger 200 RTM II 8
9
Water Plants through SCADA-Xchange North Water Plant
10
Distribution Automation Solution Overview
DA / SCADA Jerrod Gas & Electric AMI Integration via their ESB strategy using MultiSpeak Water AMI Distribution Automation Volt/VAR Control Load Control Streetlight Control Gas Cathodic Protection Gas Pressure Monitoring Sonix v2 (and RGS) RTM II
11
Electric Utility Applications Example
Capacitor Bank Recloser Regulator
12
DA System Architecture
Data interface into Utility systems, Or, stand alone system for utilities without a SCADA system Field Equipment Sensus DA endpoint Studies with data & analytics Utility Operations
13
Capacitor Bank Control
RTM Integration Serial Pass Through RS-232 Serial Connection RTM II IED Capacitor Bank Control 13
14
Examples of remote devices supported using FlexNet for smart grid applications
Manufacturer Remote Device Application Protocol ABB CQ900 Capacitor Bank Control DNP DPU2000 Recloser Control PCD2000 RER620 TPU2000 Advanced Power Technology TTC-1000 Transformer Monitor Areva MiCom P14 Feeder Protection Relay Beckwith M-2001-B Tapchanger Control M-2001-C M-6200A Voltage Regulator Control M-6280A Cannon CBC-7000 CG Automation eCap II Cooper Aries CBC-8000 CL-5 CL-6 Form 4D Form 5 Form 5 - LS Form 5 - TS Form 6 Form 6 - LS Form 6 - TS SMP4 Gateway Data Concentrator DirectLogic DL05 PLC Modbus Eaton Cutler Hammer MPCV Network Protector VaultGard ETI MNPR GE DART Power Quality Monitor Kelman TRANSFIX GE Harris D25 Substation Control Gridsense DataPac Faulted Circuit Indicator TransformerIQ HD Electric VARCOM 1600 ICMI UVR-1 Lindsey Smartpin Horstmann
15
Capacitor Bank Control
Two-way communications Central control with fallback to local Remote configuration Reduced O&M expenses Improved operational awareness Eliminated manual switching of seasonal banks
16
Voltage Regulators Demand Response Conservation voltage reduction
Tie in to Analytics software package Optimize system for peak load periods Remote configuration Obtain better planning information Receive immediate notification of regulator issues
17
Remote Control of Assets on Distribution
Example: Distributed Generation Monitor and control Reduced travel time Reduced time needed to get all generators “online” DSCADA/DMS/SCADA/EMS support Digital State Outputs, Digital State Inputs, Analog Inputs T866
18
Vault Automation Safety Know what is going on in the vault
before personnel climbs down Remote operation Improved reliability with data Valuable load information Enable distribution SCADA to these sites Reduce maintenance costs Better asset management
19
Faulted Circuit Indicators - FCI
Dispatch Crews Directly to Faults Improved Customer Satisfaction Significantly Reduced Outage Time Reduce O&M costs NaviComm Communicates with up to 12 FCIs via ‘local’ COMs Communicates up to system via FlexNet or Cellular FCI is installed on electric line 19
20
Integrating into Utility SCADA system
Sensus uses DNP 3.0 to interface into Utility SCADA (Supervisory Control and Data Acquisition) system Sensus’ DA system looks like a RTU (Remote Terminal Unit) to the SCADA system (very common interface) Sensus has worked with many/most/all of the SCADA systems in North America Boise Support will help with all DA integrations Training needs to be sold with all DA systems
21
Sensus DA Product Overview
RTM II, RTM II+ T866 TC032 NaviComm DNP 3.0 MODBUS IED Communication Gateway Reclosers Capacitor Banks Relays Voltage Regulators Switch Controls Advanced Sensors MicroRTU 8 Digital Inputs 6 Analog Inputs 6 Digital Outputs Capacitor Bank Control Switched & Fixed Voltage & Temp Neutral Current Overhead FCIs Fault Indication Fault Magnitude Timestamps Average load current Ambient Temp. 21
22
Analyzing Just the Field data You Need
23
Get the Updates you need when you need them
24
Know when a Value crosses a Specified Limit
25
DA Differences Provide communication and control to utility distribution equipment Regulators, Reclosers, Capacitor Banks Pumps, Lift Stations, Valves, Gates, Grinder Pumps Alarming -- Fast Field Knowledge Every message important Alarms Data Update for SCADA systems Open/Close, Raise/Lower Control Signals Messages acknowledged in both directions Low latency important – round trip typically < 10 seconds Communicate with lots of different utility equipment Standard interfaces used to reduce time to market
26
Benefits of using AC and FlexNet
Security Private network that is separate and utility managed infrastructure Not going to 3rd party Cell provider Encrypted VPN connection from Base Station to Sensus SaaS Data Center or Firewall to Data Center SaaS solution – Sensus takes care of all the security updates and audits Antenna Size and Coverage No large Point to Point antenna structure required Usually communicate several miles on Sensus FlexNet Speed Comparable to Cell products Immediate action (near real-time) Feedback can take 10 seconds round trip depending on configuration (serial/modbus, etc…) Data Charges No reoccurring data charge with FlexNet
27
Sensus DA Solutions Add two way communication to key powered equipment in the field Messaging acknowledged in both directions Flexible interfacing to endpoints in the field Flexible interfacing to SCADA systems WEB page based access for viewing field data Same Sensus Encryption (AES 256) supported in DA system
28
Selling the FlexNet system with DA
DA Solutions along with all the utilities other AMI solutions Water, Gas, and Electric meters, Lighting, DR, etc. Ability to get more out of the AMI system (after metering) with DA Same Encryption implementation in DA Utility FlexNet network advantages – private network for utility on licensed RF channels Multiple simultaneous 2 way communication for metering and other applications Channel Allocation Meter Data Alarms Command DA DER Future Applications FlexNet channel allocation capability
29
DA Solution COMs DA solutions can be FlexNet, AT&T 4G, Verizon 4G
The three COMs can be mixed and matched for best mix for the utility’s geographical area FlexNet COMs M400D (one radio for AMI meter message traffic and one for DA traffic) M400B (stand alone single FlexNet radio for DA) Virtual Base Station [VBS] firmware (approved for Water AMI & DA solutions only now) Ability to tunnel via FlexNet using DA solution to 3rd party endpoints connected to a RTM II (via RS-232 port) Less than 10 second round trip latency from SCADA to endpoint in the field and back. Cellular COMs Whole system Selected endpoints Communication system is cellular company’s No Base Stations needed, but lose the ‘one FlexNet system story When cell system is down or busy, the system may not be available
30
Smart Field Information
Dashboard Map View
31
Graph Your Data Graph
32
DA Dashboard
33
Dashboard detail
34
Pricing Example – 10 FlexNet endpoints
36
Pricing Example – 10 Cellular Endpoints, Part 1
37
10 Cellular Endpoints, Part 2
39
DA Hardware Endpoints
40
RTM II & RTM II+ Integration Kits (not all shown)