Presentation is loading. Please wait.

Presentation is loading. Please wait.

Date of download: 10/30/2017 Copyright © ASME. All rights reserved.

Similar presentations


Presentation on theme: "Date of download: 10/30/2017 Copyright © ASME. All rights reserved."— Presentation transcript:

1 Date of download: 10/30/2017 Copyright © ASME. All rights reserved. Assessment of Dental Implantation Osseointegration Through Electromagnetic Actuation and Detection1 J. Med. Devices. 2014;8(3): doi: / Figure Legend: Illustration of EM device for measuring dental-implantation structure resonance; (a) schematic of EM excitation and Hall-effect sensing and (b) transfer function of Y(s) to X(s) characterizing structure resonance

2 Date of download: 10/30/2017 Copyright © ASME. All rights reserved. Assessment of Dental Implantation Osseointegration Through Electromagnetic Actuation and Detection1 J. Med. Devices. 2014;8(3): doi: / Figure Legend: Block diagram of EM actuating and sensing device

3 Date of download: 10/30/2017 Copyright © ASME. All rights reserved. Assessment of Dental Implantation Osseointegration Through Electromagnetic Actuation and Detection1 J. Med. Devices. 2014;8(3): doi: / Figure Legend: Labview user/machine interface designed for EM measuring device

4 Date of download: 10/30/2017 Copyright © ASME. All rights reserved. Assessment of Dental Implantation Osseointegration Through Electromagnetic Actuation and Detection1 J. Med. Devices. 2014;8(3): doi: / Figure Legend: Measurement of a cantilever structure using the proposed EM device with a trial of (a) head-on, (b) upper side-by, and (c) lower side-by measurement. At the left-hand side of each photo a capacity displacement sensor is used to acquire vibration response for comparison.

5 Date of download: 10/30/2017 Copyright © ASME. All rights reserved. Assessment of Dental Implantation Osseointegration Through Electromagnetic Actuation and Detection1 J. Med. Devices. 2014;8(3): doi: / Figure Legend: Frequency response through head-on measurement using (a) capacity displacement sensor and (b) Hall-effect sensor

6 Date of download: 10/30/2017 Copyright © ASME. All rights reserved. Assessment of Dental Implantation Osseointegration Through Electromagnetic Actuation and Detection1 J. Med. Devices. 2014;8(3): doi: / Figure Legend: Frequency response through upper side-by measurement using (a) capacity displacement sensor and (b) Hall-effect sensor

7 Date of download: 10/30/2017 Copyright © ASME. All rights reserved. Assessment of Dental Implantation Osseointegration Through Electromagnetic Actuation and Detection1 J. Med. Devices. 2014;8(3): doi: / Figure Legend: Frequency response through lower side-by measurement using (a) capacity displacement sensor and (b) Hall-effect sensor

8 Date of download: 10/30/2017 Copyright © ASME. All rights reserved. Assessment of Dental Implantation Osseointegration Through Electromagnetic Actuation and Detection1 J. Med. Devices. 2014;8(3): doi: / Figure Legend: Photo of measurement setup using prototype EM device in the axial direction of rabbit tibia to monitor the osseointegration of implantation


Download ppt "Date of download: 10/30/2017 Copyright © ASME. All rights reserved."

Similar presentations


Ads by Google