Top Hits in the Physical Environment September Billy Kinch, MHA, HACP CIHQ - All Rights Reserved 2017

2 Presentation Objectives
By the conclusion of this program, the participant will be able to: Identify the top findings from the physical environment Strategies for maintaining compliance CIHQ – All Rights Reserved 2017

3 How To Impress a Life Safety Surveyor
When asked a question about the Life Safety Code. Your first response is always “IT DEPENDS!” Be able to point out what a sprinkler escutcheon is CIHQ - All Rights Reserved 2017

4 CIHQ - All Rights Reserved 2017
Top Findings Security Risk Assessment Psychiatric Units DOT Training Eye Wash Stations Junction Boxes Testing Documentation Emergency Lighting Emergency Power Generator Inspection Electrical Panels IT Closets Equipment Inventory Cylinder Storage Power Strips Temperature/Humidity Ventilation Medical Gas Shut-off Valves Fire/Smoke Barrier Sprinkler Hazardous Areas Doors Means of Egress CIHQ - All Rights Reserved 2017

5 Security Risk Assessment
Infant Security National Center for Missing and Exploited Children Cyber Security CIHQ - All Rights Reserved 2017

6 CIHQ - All Rights Reserved 2017
Psychiatric Units Assessment Design Guide for the Built Environment of Behavioral Health Facilities Ligature Points CIHQ - All Rights Reserved 2017

7 CIHQ - All Rights Reserved 2017
DOT Training Department of Transportation Training Requirements Hazmat Employee Loads, unloads, or handles hazmat Prepares hazmat for transportation Signs waste manifests Training required within 90 days of hire and 3 years thereafter Training Records the hazmat employee’s name; the completion date of the most recent training; training materials used (copy, description, or location); the name and address of the hazmat trainer; and certification that the hazmat employee has been trained and tested CIHQ - All Rights Reserved 2017

8 CIHQ - All Rights Reserved 2017
Eye Wash Stations ANSI Z Plumbed vs. Non-plumbed Weekly Inspections Annual Inspections CIHQ - All Rights Reserved 2017

9 CIHQ - All Rights Reserved 2017
Junction Boxes Must be closed Creates a fire hazard CIHQ - All Rights Reserved 2017

10 Testing Documentation
Sets the tone of the survey Inventory of devices Pass/Fail documentation Corrective action and retest for failed devices Other requirements based on device tested Updated versions of NFPA codes Checklist on CIHQ Website CIHQ - All Rights Reserved 2017

11 CIHQ - All Rights Reserved 2017
Emergency Lighting EXIT Signs NFPA Battery Powered Lights NFPA CIHQ - All Rights Reserved 2017

12 CIHQ - All Rights Reserved 2017
Emergency Power Manual Stop Button NFPA CIHQ - All Rights Reserved 2017

13 Generator Inspections
Annual Fuel Quality Test Based on ASTM Standards Weekly inspections CIHQ - All Rights Reserved 2017

14 CIHQ - All Rights Reserved 2017
Electrical Panels Must have a 36-inch clearance Directory must be complete – including spares CIHQ - All Rights Reserved 2017

15 CIHQ - All Rights Reserved 2017
IT Closets Unsealed penetrations Plywood on walls – NFPA / CIHQ - All Rights Reserved 2017

16 CIHQ - All Rights Reserved 2017
Equipment Inventory Written Inventory of Equipment Unique ID Number Equipment Manufacturer Equipment Model Number Equipment Serial Number Description of Equipment Location of Equipment (when kept in a fixed location) Department considered to own equipment Service Provider Acceptance Date CIHQ - All Rights Reserved 2017

17 CIHQ - All Rights Reserved 2017
Cylinder Storage Less than 300 cubic feet ,000 cubic feet 3,000 – 30,000 cubic feet E-Cylinder = 23 cubic feet H-Cylinder = 244 cubic feet Full vs. Empty/In-Use CIHQ - All Rights Reserved 2017

18 CIHQ - All Rights Reserved 2017
Power Strips Patient Care Vicinity UL1363A or – Patient Care Equipment UL1363 – Non-patient Care Equipment Permanently Affixed 75% of Rating Included on Inventory Routine Maintenance CIHQ - All Rights Reserved 2017

19 Temperature/Humidity
Proper ranges No corrective action ASHRAE CIHQ - All Rights Reserved 2017

20 CIHQ - All Rights Reserved 2017
Ventilation Improper pressures ASHRAE CIHQ - All Rights Reserved 2017

21 Medical Gas Shut-off Valves
Properly Labeled Blocked Access CIHQ - All Rights Reserved 2017

22 CIHQ - All Rights Reserved 2017
Fire/Smoke Barrier Unsealed penetrations NFPA Not properly marked on the Life Safety drawings Doors NFPA CIHQ - All Rights Reserved 2017

23 CIHQ - All Rights Reserved 2017
Sprinkler Missing escutcheon NFPA Items being supported on sprinkle pipe NFPA Spare sprinkler heads/wrench NFPA Testing documentation CIHQ - All Rights Reserved 2017

24 CIHQ - All Rights Reserved 2017
Hazardous Areas Not properly identified on drawings Doors not latching NFPA / Not properly rated room CIHQ - All Rights Reserved 2017

25 CIHQ - All Rights Reserved 2017
Doors Fire doors having missing or painted over rating labels NFPA Not properly latching NFPA Door wedges NFPA CIHQ - All Rights Reserved 2017

26 CIHQ - All Rights Reserved 2017
Means of Egress Hallway clutter NFPA / Special Locking Arrangements NFPA / Confusing Exits NFPA Wheeled Equipment CIHQ - All Rights Reserved 2017

27 © CIHQ – All Rights Reserved 2017
That’s Enough Thanks for listening. Any Questions?    © CIHQ – All Rights Reserved 2017