Download presentation
Presentation is loading. Please wait.
Published byPearl Campbell Modified over 6 years ago
1
Date of download: 10/31/2017 Copyright © ASME. All rights reserved. From: Direct JP-8 Conversion Using a Liquid Tin Anode Solid Oxide Fuel Cell (LTA-SOFC) for Military Applications J. Fuel Cell Sci. Technol. 2011;8(4): doi: / Figure Legend: Power density curves at 1000°C show that the maximum sustainable power is 120mWcm−2 for JP-8, and also illustrates that peak power is still to be reached
2
Date of download: 10/31/2017 Copyright © ASME. All rights reserved. From: Direct JP-8 Conversion Using a Liquid Tin Anode Solid Oxide Fuel Cell (LTA-SOFC) for Military Applications J. Fuel Cell Sci. Technol. 2011;8(4): doi: / Figure Legend: The initial single cell 100h durability test at JP-8 flow rate of 10μlmin−1 showed no performance degradation
3
Date of download: 10/31/2017 Copyright © ASME. All rights reserved. From: Direct JP-8 Conversion Using a Liquid Tin Anode Solid Oxide Fuel Cell (LTA-SOFC) for Military Applications J. Fuel Cell Sci. Technol. 2011;8(4): doi: / Figure Legend: An average efficiency of 41.29% at 76mWcm−2 was sustained for an hour on the single cell used for the 100h durability test, this cell also demonstrated efficiencies of 26.18% and 31.35% at power densities of 48mWcm−2 and 58mWcm−2, respectively
4
Date of download: 10/31/2017 Copyright © ASME. All rights reserved. From: Direct JP-8 Conversion Using a Liquid Tin Anode Solid Oxide Fuel Cell (LTA-SOFC) for Military Applications J. Fuel Cell Sci. Technol. 2011;8(4): doi: / Figure Legend: The system schematic illustrating that a LTA-SOFC does not require the typical BOP associated with SOFC running on JP-8 and therefore allowing weight and volumetric savings
5
Date of download: 10/31/2017 Copyright © ASME. All rights reserved. From: Direct JP-8 Conversion Using a Liquid Tin Anode Solid Oxide Fuel Cell (LTA-SOFC) for Military Applications J. Fuel Cell Sci. Technol. 2011;8(4): doi: / Figure Legend: A projection of system efficiency as a function of fuel weight saving shows that the ability to operate a liquid tin anode SOFC at an efficiency of 40% will equate to substantial weight savings for a portable device
6
Date of download: 10/31/2017 Copyright © ASME. All rights reserved. From: Direct JP-8 Conversion Using a Liquid Tin Anode Solid Oxide Fuel Cell (LTA-SOFC) for Military Applications J. Fuel Cell Sci. Technol. 2011;8(4): doi: / Figure Legend: A nominal 250W system design on a LTA-SOFC directly converting JP-8 at 30% efficiency would have a comparable dry weight to the CERDEC draft battery charger specification and a fuel weight that is less than half the specified fuel weight
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.