Direct Flow Medical Experience with a Conformable, Repositionable Retrievable Percutaneous Aortic Valve Reginald Low MD University of California, Davis Sacramento, California
2
Disclosures Abbott Vascular - Consultant
Boston Scientific - Consultant Direct Flow Medical - Consultant UC Davis
3
Introduction Feasibility, safety, and efficacy of TAVR with Edwards-Sapien and Medtronic CoreValve have been well demonstrated Large Effective Orifice Area Durability Securement No coronary obstruction Multiple sizes Delivery profile Opportunities for improvement Reduction of paravalvular insufficiency Improved access Profile, flexibilty and trackability Assess function before final deployment Precise positioning Repositioning Retrievable UC Davis
4
Direct Flow Medical Percutaneous Aortic Valve
Design Features Bovine Pericardium Leaflets (anti-calcification treatment) Balloon Frame covered with Polyester Fabric Initial deployment - inflate frame with Saline/Contrast When acceptable final position and function are confirmed, Polymer media is infused to replace saline/contrast 18 French deliviery system Valve sizes - 25 mm, 27 mm treats annulus diameter mm 3 check valves Valve is immediately functional when unsheathed and distal ring is inflated UC Davis
5
Direct Flow Medical Percutaneous Aortic Valve
Design Features Delivery System Polymer nylon sleeve Multi-lumen catheter 3 position and fill wires 1 guide wire lumen Flexible nose cone Non-metallic delivery system and valve Flexible and trackable Precise positioning Retrievable with deflation and withdrawl into retrieval basket Position & Fill Lumens Aortic Ring Ventricular Ring Guidewire Lumen UC Davis
6
Direct Flow Medical Percutaneous Aortic Valve
Valve loaded in Delivery System Valve Unsheathed Valve Inflated & Steering System Valve in Retrieval Basket UC Davis
7
Inflation, Deflation & Media Exchange
UC Davis
8
Positioning & Securement
UC Davis
9
Deliverability & Sealing
UC Davis
10
Complex Valve and Vascular Anatomy
87 year old male Euroscore = 36.2 Moderately Calcified Leaflets &Native Annulus Extensive Calcification Marked Tortuosity 6 Month CT Current Status: 52 Months Post-Procedure Final Position UC Davis
11
Tracking - Aortic Arch Deliverable and precisely positionable in any arch configuration including Horizontal Arch UC Davis
12
Case Review: 009-01-003 (Cali) Access Summary No Complications
UC Davis
13
Balloon Aortic Valvuloplasty
UC Davis
14
Annulus and Procedure Results
Systole Symmetric Calcium Score 1051 Diastole UC Davis
15
Case Summary UC Davis
16
Echo Pre Procedure Post TAVR Procedure UC Davis
17
Important Feature No significant paravalvular leak - aortic insufficiency UC Davis
18
Important Feature No significant paravalvular leak - aortic insufficiency UC Davis
19
Important Feature Important Feature
No significant paravalvular leak - aortic insufficiency UC Davis
20
Important Feature No significant paravalvular leak - aortic insufficiency UC Davis
21
Important Feature No significant paravalvular leak - aortic insufficiency UC Davis
22
22 French Early Experience
University Medical Center, Hamburg-Eppendorf (n=25) Helios Heart Center - Siegburg (n=6) High risk patients for cardiac surgery Patients Enrollment Number / 22 Implants / 2 Surgical Conversions Age ± 4 years Female/Male /15 NYHA III – IV % Logistic EuroSCORE ± 7% Mean transvalvular gradient ± 14 mmHg Aortic valve area ± 0.13 cm2 LVEF ± 15% UC Davis
23
22 French Early Experience 2 Year Data
Effective orifice area cm2 Mean Echo gradient Functional Class I (75%) or II Aortic insufficiency - 73% none & 27% minimal 2 year survival % CT - No change in position, diameter and orifice area over time Echo - Gradient 50.1±11.3 to 19.6±5.7 at 30 days - No change over time AVA - Baseline 0.57±0.15 cm2 to 1.47±0.35 cm2 at 30 days - No change over time UC Davis Bujuklic K et al. Circ Cardiovasc Interv Dec 1;4(6):
24
Present Studies Latest iteration (18 Fr) improved profile, positioning, valve loading into delivery sheath, radial force, valve competence, & simplified media exchange IP South America - Colombia Study IP European CE March Trial France, Germany, Italy UC Davis
25
Summary Direct Flow Medical Percutaneous Aortic Valve
Non-metallic fabric covered balloon supported bovine pericardial valve with excellent trackability and deliverability Precise positioning, repositionable and retrievable Mechanical securement with conformability and sealing to minimize paravalvular leak Formed in-situ with exchange polymer media Design permits functional and hemodynamic assessment before final deployment Feasibility, safety and efficacy demonstrated with 22 F system European study with longest implant of 4.3 years CE Mark and South American (Colombia) trial enrolling No or trace paravalvular leak & no screening failures for peripheral access UC Davis