1 Shower detector status report
P. Salabura XXIII collaboration meeting /GSI Darmstadt

2 Shower operation in Au+Au
Detector HV: V (18 chambers) new electronics: higher electronic gain (~10) :  lowering of HV working point by 250 V w.r.t Currents : (~7uA/plane) at 3*10^6/spill (spill is 1.5s) Gas flow: 10 l/hour/chamber 48%Ar : 50% Isobuthan (and 1-2% n-hepthane vapor) 1 event/beam time with chamber ignition (Pre1/Post1 sector 2 at the same time)

3 PreShower matching with tracks (DST-Gen0)
Sz. Harabasz) Tracks & RPC hits Tracks & RPC hits & match_qual<4 All tracks Tracks & RPC hits & Pre-shower match_qual Tracks & RPC hits & match_qual<4? Tracks & RPC hits & Pre match_qual? Tracks & RPC hits & Pre &post1 match_qual? RPC - Pre X [mm] Max Hit Prob / pad ~ 1.3% Averaged %

4 Mean of Q vs particle velocity
Example : Post1 All particles Negative pions Velocity () from RPC-tracking 10-15% differences between moduls –needs calibration for ePID

5 Mean of Q vs (x,y)-gain uniformity
example: Pre chamber Mean (Q) for protons Negative pions Rows (y) – related to  columns (x) – related to  channel: Nr. column + i*Nr.Row 20% variations from edge to centrum : similar for all chambers ! (no need for calibration?)

6 Averaged efficiency vs 
Pre Post1 Post2 example : Pre chamber Reference RPC-Post1 Pre chamber Pre chambers Negative pions All partciles Similar results for Post1

7 2d efficiency efficiency of Post1 RPC/Pre – Post2 as reference
Negative pions p>150 MeV/c All particles

8 Shower - readout status
Stable operation during whole beamtime Calibration mode and data taking mode OK. but ! timing problem in FPGA firmaware leads to corrupted ADC data (not present last year) ~4% channels concerned – (one row 25 on Post)

9 Shower – read-out problem
Row 25 : Post2 OK charge (Y) vs column Row 25 : Post1 NOT OK Needs another iteration by experts … (Marek/Greg/Marcin…)

10 Shower Summary 18 chambers working Peformance looks OK.- electrons?
Timing Problem in ADC remains to be solved..