Download presentation
Presentation is loading. Please wait.
Published byGavin Maxwell Modified over 6 years ago
1
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: An Active Dynamic Vibration Absorber for a Hand-Held Vibro-Elastography Probe J. Vib. Acoust. 2006;129(1): doi: / Figure Legend: Hard and soft inclusions are subject to an external compression (F)
2
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: An Active Dynamic Vibration Absorber for a Hand-Held Vibro-Elastography Probe J. Vib. Acoust. 2006;129(1): doi: / Figure Legend: DVA with zero damping attached to the primary system
3
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: An Active Dynamic Vibration Absorber for a Hand-Held Vibro-Elastography Probe J. Vib. Acoust. 2006;129(1): doi: / Figure Legend: Active DVA attached to the primary system
4
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: An Active Dynamic Vibration Absorber for a Hand-Held Vibro-Elastography Probe J. Vib. Acoust. 2006;129(1): doi: / Figure Legend: Block diagram representation of the PI controller
5
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: An Active Dynamic Vibration Absorber for a Hand-Held Vibro-Elastography Probe J. Vib. Acoust. 2006;129(1): doi: / Figure Legend: Stability chart. Kp and frequency versus Ki. The dashed and solid curves correspond to the combined system and absorber system, respectively.
6
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: An Active Dynamic Vibration Absorber for a Hand-Held Vibro-Elastography Probe J. Vib. Acoust. 2006;129(1): doi: / Figure Legend: Minimum operational frequency versus k
7
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: An Active Dynamic Vibration Absorber for a Hand-Held Vibro-Elastography Probe J. Vib. Acoust. 2006;129(1): doi: / Figure Legend: Root locus plot of the poles of the transfer function of the PD with absolute absorber mass position and velocity, neglecting the dynamics of the actuator and filters
8
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: An Active Dynamic Vibration Absorber for a Hand-Held Vibro-Elastography Probe J. Vib. Acoust. 2006;129(1): doi: / Figure Legend: Root locus plot of the poles of the transfer function of the PD with relative absorber mass position and velocity, neglecting the dynamics of the actuator and filters
9
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: An Active Dynamic Vibration Absorber for a Hand-Held Vibro-Elastography Probe J. Vib. Acoust. 2006;129(1): doi: / Figure Legend: Root locus plot of PI transfer function’s poles, neglecting the dynamics of the actuator and filters
10
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: An Active Dynamic Vibration Absorber for a Hand-Held Vibro-Elastography Probe J. Vib. Acoust. 2006;129(1): doi: / Figure Legend: Root locus plot of DR transfer function’s poles and zeros, neglecting the dynamics of the actuator and filters
11
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: An Active Dynamic Vibration Absorber for a Hand-Held Vibro-Elastography Probe J. Vib. Acoust. 2006;129(1): doi: / Figure Legend: The hand-held device held by the mechanical arm
12
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: An Active Dynamic Vibration Absorber for a Hand-Held Vibro-Elastography Probe J. Vib. Acoust. 2006;129(1): doi: / Figure Legend: Probe vibration for experiments with a human operator on real tissue. The vibration absorber is turned on at t=0.7
13
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: An Active Dynamic Vibration Absorber for a Hand-Held Vibro-Elastography Probe J. Vib. Acoust. 2006;129(1): doi: / Figure Legend: Ωi for i=3 and its corresponding ωe
Similar presentations
© 2025 SlidePlayer.com. Inc.