Presentation is loading. Please wait.

Presentation is loading. Please wait.

DHCAL and MICROMEGAS at LAPP

Similar presentations


Presentation on theme: "DHCAL and MICROMEGAS at LAPP"— Presentation transcript:

1 DHCAL and MICROMEGAS at LAPP
Catherine Adloff Franck Cadoux Sébastien Cap Cyril Drancourt Ambroise Espagilière Raphael Gallet Claude Girard Nicolas Geffroy Richard Hermel Kostas Karakostas (invité) Yannis Karyotakis Inocencio Monteiro Fabrice Peltier Julie Prast 24 Jan 2008 DHCAL Meeting

2 MicroMegas Prototypes
PCB and bulk from CERN (Rui de Oliveira) 325 LPI mesh spacers : 120 m heigh m diameter pads : 0.98x0.98 cm2, 200m between pads The chamber 95% Argon, 5% Isobutane conversion volume (3mm) a top in Stainless Steel with a cupper drift cathode The pad readout : analogue Gassiplex board : 6 gassiplex chips - 96 channels Electronics card built for CAST by DAPNIA (P. Colas, Philippe Abbon) VME sequencer and ADC from CAEN CENTAURE acquisition (SUBATECH, Nantes, D.Roy) DHCAL Meeting 24 Jan 2008

3 MicroMegas Studies X-ray studies (5.9 keV) Cosmics Gain
Response versus Vmesh Response versus Vdrift Gas flow dependencies Time stability HV supply dependencies Cosmics MIP value measurement First glance on X-talk DHCAL Meeting 24 Jan 2008

4 all pads : 96 entries for each trigger
X-ray Results 55Fe source (5.9 keV  228e in drift volume) Trigger on mesh : preamp (T output) + fast ampli Vmesh = 420 V Vdrift = 470 V Emesh = 35 kV/cm Edrift = 167 V/cm Entries ADC Counts all pads : 96 entries for each trigger escape peak A. Espargilière pedestal @ 20 ADC X-ray keV Gassiplex Readout : Peak = 680 ADC cnts = 996 mV  277 fC  Gain 7600 FWHM = 25.5% T2K(same techno) : FWHM = 26% DHCAL Meeting 24 Jan 2008

5 X-ray Results (K. Karakostas)
Vmesh = 390 V Vdrift = 440 V Emesh = 32.5 kV/cm Edrift = 167 V/cm T1 Optimisation for Gassiplex readout Mean (ADC Counts) Pad signal : Gassiplex readout K. Karakostas T1 (ns) Charge = 820(1500mV)/1024/3.6(mV/fC) = 334 fC DHCAL Meeting 24 Jan 2008

6 X-ray Results expected exponential behaviour Response versus Vmesh
K. Karakostas Vdrift = Vmesh + 70 V Edrift = 233 V/cm expected exponential behaviour DHCAL Meeting 24 Jan 2008

7 X-ray Results Saturates for Flow > 0.20 l/h  7 volume/h
Response versus Vdrift and Gas flow dependencies K. Karakostas Vmesh = 395 V Emesh = 33 kV/cm Edrift = V/cm Saturates for Flow > 0.20 l/h  7 volume/h Gain  when Drift field  DHCAL Meeting 24 Jan 2008

8 X-ray Results Gain  when Atmospheric Pressure  Time Stability
K. Karakostas Gain  when Atmospheric Pressure  DHCAL Meeting 24 Jan 2008

9 X-ray Results Slope = - 4.9 ADC/mbar = 2 fC/mbar
Time Stability Slope = ADC/mbar = 2 fC/mbar K. Karakostas Gain  when Atmospheric Pressure  DHCAL Meeting 24 Jan 2008

10 X-ray Results HV supply dependencies
Vmesh = 390 V Vdrift = 450 V Emesh = 32.5 kV/cm Edrift = 200 V/cm HV supply dependencies old and not reliable HV supply No significant difference between HV supplies DHCAL Meeting 24 Jan 2008

11 Cosmics Trigger on 3 scintillators coincidence
Mesh Signal : Preamp (E output) + shaper (gain=25) Charge  210(mV)/25/0.312(mV/fC) = 27 fC DHCAL Meeting 24 Jan 2008

12 Cosmics Gassiplex Readout Charge  80(1500mV)/1024/3.6(mV/fC) = 32 fC
Chamber mapping (geographic occupancy) Pad with highest signal Nb of Events Mean (Pedestal) = 21 Sigma(Pedestal) = 1.4 muon selection : ADC(Pad with highest signal) > 40 reflects scintillators geometry ADC Counts Charge  80(1500mV)/1024/3.6(mV/fC) = 32 fC Gain  6900 DHCAL Meeting 24 Jan 2008

13 Cosmics Dominant Crosstalk?
After muon selection : distance between pad with highest signal (muon pad) and pad with 2nd highest signal (second pad) Normalised Number of Events (%) PCB routing along X (same Y than muon pad) 20% of the events with a muon have the second highest signal close to the muon pad Dominant Crosstalk? DHCAL Meeting 24 Jan 2008

14 Future X-ray, source, TB Mini analogue calorimeter prototype
pad homogeneity (cosmics, TB) prototypes disparity X-talk different gas mixture efficiency (cosmics, TB) Mini analogue calorimeter prototype 3 MicroMegas 6cmx16cm 2 MicroMegas 12cmx32cm DHCAL Meeting 24 Jan 2008


Download ppt "DHCAL and MICROMEGAS at LAPP"

Similar presentations


Ads by Google