Download presentation
Presentation is loading. Please wait.
Published byPaul Hodges Modified over 6 years ago
1
How important is it to consider target properties and hematocrit in bloodstain pattern analysis?
Sungu Kim, Yuan Ma, Prashant Agrawal, Daniel Attinger Forensic Science International Volume 266, Pages (September 2016) DOI: /j.forsciint Copyright © Terms and Conditions
2
Fig. 1 Before each measurement, the non-Newtonian, shear-thinning viscosity of the blood is measured with a capillary viscometer built according to this schematic. Forensic Science International , DOI: ( /j.forsciint ) Copyright © Terms and Conditions
3
Fig. 2 The viscosity of swine blood as a function of shear rate. The plotted data was obtained at a room temperature of T=27.1°C, and hematocrit H=37.5%, corresponding to measurement C in Table 1. Forensic Science International , DOI: ( /j.forsciint ) Copyright © Terms and Conditions
4
Fig. 3 Experimental setup for conducting blood impact experiments.
Forensic Science International , DOI: ( /j.forsciint ) Copyright © Terms and Conditions
5
Fig. 4 Evolution of drop spreading on different targets. (a) Polycarbonate bare, (b) Glass, (c) Aluminum, (d) Cardstock. The yellow lines represent the maximum extent of the spreading of the rim. The white lines represent the center of the droplet. The droplet height is 20cm for all the cases in the figure. Corresponding non-dimensional numbers are: Re=1200, We=158 and Oh=0.010. Forensic Science International , DOI: ( /j.forsciint ) Copyright © Terms and Conditions
6
Fig. 5 Experimental correlations between the spreading factor and the non-dimensional number Re2Oh, as a function of the target. The correlations are tabulated in Table 3. Forensic Science International , DOI: ( /j.forsciint ) Copyright © Terms and Conditions
7
Fig. 6 Comparison of the ratio (HR) of estimated drop height to the experimental drop height using correlations of different targets for drop impact on aluminum mirror. All the droplet release heights used in the experiment (i.e. 5, 10, 20, 60 and 150cm) were taken as the reference height to calculate HR. The drop release heights were calculated with and without considering drag force on the droplet. Forensic Science International , DOI: ( /j.forsciint ) Copyright © Terms and Conditions
8
Fig. 7 Variation of the estimated droplet release height for a spreading factor β=3 and 3.9, assuming 44% hematocrit, as a function of the actual value of hematocrit. The droplet release height was estimated with and without considering the drag force acting on the droplet. Forensic Science International , DOI: ( /j.forsciint ) Copyright © Terms and Conditions
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.