Ship Electric Power Systems: Activities at MIT
J. L. Kirtley Jr. ESRDC Team Meeting May 20, 2008
2
Non-Intrusive Load Monitor
3
Ship-board Installation
Voltage Board Power Supply Monitor Mini-PC Output to PC NILM Box UPS Current Input Voltage Input
4
Transient-Based Identification
Transient electrical behavior is strongly influenced by the physical task performed by the load
5
Spectral Envelopes Stator current and P1 for a 3-phase induction motor
6
Field Experiments USCG Cutters Seneca and Escanaba USN DDG-51 LBES
7
Field Condition Based Monitoring
Cycling Systems, e.g., waste disposal Auxiliary Sea Water (ASW) Reverse Osmosis Steering Gear HVAC Roll-Fin Control Prop Pitch Control Electrical Distribution Anchor Windlass Gas Turbine Generators (GTG) Gas Turbine Propulsion (GTM) Gas Turbine Support Systems
8
Reconfiguration During Escanaba Check Valve Leak
A trade-off: increased wear and energy expense during the (hopefully brief) reconfiguration period before casualty repair.
9
On three separate occasions we have been presented with NILM data showing improper operation…This data steered us directly to the malfunctions weeks before they became mission critical.
10
Conclusion Significant success using nonintrusive electrical load monitoring to diagnose system faults in electromechanical systems. Successful installations on-board USCGC Seneca, USCGC Escanaba, and at the USN DDG-51 LBES facility. Goal: collaborate with a USN crew to use the NILM to detect and remediate electromechanical problems before they become mission cripples.
11
Zonal Distribution: DDG-51
12
Multi-function Monitor
MFM III
13
Stolen from the NGIPS Technology Development Roadmap
30 Nov 2007
14
Top Level System Architecture
15
Power Systems on Ships:
Generation Drive Motors and Drives This is one of many notional diagrams to show functionality of the ship electric power system House and Mission Loads Distribution: Wires, Switches and Controls
16
Choices that will impact ship effectiveness and cost (among others):
Generation: Range of ratings Distribution: AC or DC; AC frequency Voltage Level Topology Drive Motors Type Location Controls Supervisory NILM Reconfiguration Storage
17
Generators Ratings Distribution Frequency Voltage Topology Control Strategy Loads Storage Architectural Model Performance Metrics Efficiency Stability Quality of Service Maintainability Cost Weight
18
Modular Podded Propulsion System
Multiple Modules for Redundancy Enhanced TORUS: PM Rotors are Free Spinning Can be stopped if faulted Maintains advantages of PM AND DFM Can un-clutch a section to stop damage from a fault