1
DCR Current Sensing DCR Current Sensing can be used to remove the additional conduction loss introduced by current sense resistor. The voltage across DCR can be extracted using a R-C network. Matching R1C time constant with L/DCR time constant π
1ΓπΆ=πΏ/π·πΆπ
Then Equivalent Current Sense Resistance will be π πΆ = π π·πΆπ
π
π πππ π =π·πΆπ
2
DCR Current Sensing (DCR is higher than desired current sense resistance)
Matching the time constants π
1Γπ
2 π
1+π
2 ΓπΆ=πΏ/π·πΆπ
Equivalent Current Sense Resistance π
π πππ π = π
2 π
1+π
2 Γπ·πΆπ