Current Sharing and AC losses in Coated Conductor Roebel Cables -- HEP Applications
M.D. Sumption, M. Majoros, E.W. Collings Center for Superconducting and Magnetic Materials, MSE, The Ohio State University Nick Long, IRL, New Zealand EUCAS 2011 Centennial Den Haag W. Goldacker A. Nijhuis, E Kershoop, The University of Twente, EMS Group This work was funded by the U.S. Dept. of Energy, Division of High Energy Physics, under Grant No. Grant No. DE-FG02-95ER40900 (University Program)
2
Outline Roebel Cables in the context of HEP
Roebel Cables as Topological transformations of Rutherford Cables Loss Expressions, Contact Resistance Expressions Direct I-V measurements of Interstrand Contact Resistance AC Loss and Its relation to ICR Measurements of Roebel with Helium gas flow induced temperature gradients G. Levin
3
YBCO Roebel in HEP Context
It is useful to consider YBCO for HEP magnets for very high field devices, like 50 T solenoids for muon colliders, because they are enabling. Worth considering for other HEP magnets as well Large magnets need cables, typically tens of kAs Cables need current sharing between the strands for stability and protection reasons in LTS, as well as current distribution uniformity considerations Strand to strand contacts must be low resistance enough to allow this, but high enough to keep low loss These same considerations needed for Rutherford cables will need to be applied to Roebels, and it is easy to see why since …….
4
The Roebel is a topological transformation of a Rutherford Cable
i.e., no cutting or pasting operations allowed Operation 2 flatten Operation 1 rotate Operation 3 flatten some more
5
Roebel as Topological transformation of Rutherford II
This fact is long known, although perhaps not well known So what? The important point is that the loss current paths, the losses of which have been calculated in detail, transform topologically as well
6
Topological equivalence of coupling current paths in Roebel and Rutherford cables
FO Coupling loop, involves R R, this is a connection between “top”and “bottom” layer strands In the Roebel cable this would mean left and right side connections, and these don’t exist dB/dt dB/dt EO Loop, R// Old EO Loop Transformed, would imply strand 1 having continuous contact with strand 2, and 2 with 3, and 3 with 4 etc, all on the strand faces. In fact this is true, but the R involved can be high
7
Use of Rutherford Expressions for Roebel
For Rutherford cables the AC Loss expressions for coupling loss per cycle per m3 are EO FO EO FO Realizing that Rc is infinite, then both field applied to the face and field applied to the edge of the Roebel cable will follow With different proportionality constants in front for cable face and cable edge orientations and Ra refers to nearest strand contact, e.g., 1-2, 2-3, etc
8
Similarity in Problems, similarity in solutions
In Rutherford cables, the main item controlling contact resistance is the oxide layer on the Cu (or other surface metal) – this is also true for YBCO One way of overcoming this in Rutherford cables was by controlled low temperature sintering of the cables to break down the surface oxide layers, we could try that (did not work so well, see below) Another was of overcoming this was the use of a Ag-Sn solder, which was ductile, and pressure responsive, and replaced the heavy CU oxide with a lighter one –this is our motivation for using a Sn sheet for contacts in Roebel below In some cases, contacts were soldered, we also tried this We start out by seeing how simple pressure effects the contacts
9
Attempt to Create Current Sharing in YBCO Roebel Cables
Oxide layers on Cu stabilizer suppress current sharing, as they did for NbTi cables used in accelerator magnets There, the problem was solved with low temperature “cures” under slight pressure to sinter Cu surfaces (140C/1/2 h, 25 MPa) We recently attempted 170C for 2 h, but low pressure (< 5 MPa), and then measured via helium boiloff calorimetry
10
IBAD Based Roebel (Cables 1 and 2)
Measurements at 77 K and 4 K Two different Cables R1 from IRL R2 from KFK Nick Long, IRL, New Zealand W. Goldacker
11
4.2 K Calorimetric Loss Measurements Cable 1
AC losses are hysteretic, independent of frequency Cable Results for Cable 2 done at higher Freq also no coupling loss
12
Results of Try #1 -- loss section
For As-received Roebel cable the strands have no coupling This means no eddy current loss, but also no current sharing This is due to the native oxide layers on the Cu stabilizer Mild Curing of the cable of the kind which worked to control ICR in NbTi Rutherford cables did not work – at least at the low pressures we used
13
Trial # 2 -- Contact Resistance Measurements in Roebel Cables by Direct I-V
We used a direct I-V measurement to obtain contact resistance, Rc, between strands in a cable We used the method described by Verweij Measurements are made at RT, at 77 K, and then with applied pressure applied pressure with Soft metal pressure contact soldered contacts
14
Direct Contact Method for ICR
We can adopt the direct I-V technique used by Arian Verweij in his measurement of ICR in Rutherford cables, see “Electrodynamics of Superconducting cables in Accelerator Magnets, Thesis, University of Twente 1995 Rmax R// only Rc as well Another way to see this is that we have N resistors in parallel, and N/2 series segments of these Our case corresponds to his Eq 4.46 b, except that the Ra used there is slightly different, and given that our cable length is equal to Lp, we get Ra = 2Rmax
15
Wiring of the cable Number of tapes: 15
Current contact on one end of the cable – tape no. 2 Current contact on the other end of the cable – tape no. 10 DC power supply: HP6634 A (1 A – 100 V) Voltmeter: Keithley 2182A nanovoltmeter Pairs of the potential taps used for voltage measurements: 1-2, 1-3, 1-4, …. 1-15 Cable Provided by Industrial Research Limited, IRL
16
Pressure application Pressure was applied by adding stainless steel plates on top of the G-10 top plate, both were free to move up and down but stabilized laterally by guide rods
17
(baseline) 77 K Results for zero Applied Pressure
I = 500 mA Vmax = 225 mV Rmax = 450 m Liquid nitrogen bath (77.3 K) data (no pressure applied): contact no. 1 = potential taps 1-2, contact no. 2 = potential taps 1-3, …… contact no. 14 = potential taps 1-15.
18
(a) Effect of Pressure Application 77 K – no interlayer metal
No Pressure 77 K I = 500 mA Vmax = 225 mV Rmax = 450 m Max Pressure 77 K Vmax = 70 mV Rmax= 140 m Max Pressure is 95 kPA Pressure is applied to the wide face of the cable by stacking metal plates, the weight of which cause a pressure
19
(b) Roebel Cable with Soft metal interlayer under pressure
Max Pressure is 95 kPA Effect of pressure on transverse resistance of the cable with Sn foil on its top, measured in liquid nitrogen bath (77.3 K). Pressure measured in number of steel “bricks” used as a load. Sn+ 1 brick 77 K I = 500 mA Vmax = 30 mV Rmax = 60 m Sn+ 4 brick 77 K I = 500 mA Vmax = 16 mV Rmax= 32 m
20
(b) Roebel Cable with Soft metal interlayer under pressure
Max Pressure is 95 kPA Effect of presence of Sn foil on transverse resistance of the cable at maximum pressure of 4 steel bricks, measured in liquid nitrogen bath (77.3 K). No Sn+ 4 brick 77 K I = 500 mA Vmax = 55 mV Rmax = 110 m Sn+ 4 brick 77 K I = 500 mA Vmax = 16 mV Rmax= 32 m
21
ICR Results so Far
22
Roebel Cable with Indium Soldered Cu bridges
The above techniques has induced some contact, but not enough – how about in soldered Cu shunts? Inspired both by previous soldering work, and work done at IRL (Long)
23
(c) Roebel with Indium Soldered Cu shunts – 77 K data
Roebel cable IRL (2011) with In soldered Cu bridges –– LN2 data. (contact no. 1 = potential taps 1-2, contact no. 2 = potential taps 1-3, …… contact no. 14 = potential taps 1-15). I=0.5 A Vmax=50 Rmax = 100
24
ICR Results with Solder addition
25
New Series of Loss Measurements on Soldered cable
We might expect increased coupling loss to now be seen for Roebels with soldered junctions Let’s see …
26
AC Loss Results for Roebel with Indium soldered Cu shunts
No apparent increase in loss! ICR would appear not to have changed!
27
Higher frequency loss at 77 K for Roebel with soldered contacts
Roebel cable from IRL (2011) indium-soldered Cu bridges –– LN2 in-field ac losses at different frequencies
28
What are the expected resistances of the contacts?
Resistance of Solder contacts R = L/A = 15 cm*10*10-4cm/1cm2 = 15 n Resistance of 0.1 mm thick Cu strip (1cm sq) R = L/A = (1.6 cm/RR(T))*1 cm/0.01cm2 = at 77 K, RR(T)=5, and R = 160 Reasonable agreement with the direct ICR at 4 K, RR(T) = 100, and R = 8 Similar to what might be a target for a Rutherford accelerator strand
29
4.2 K NbTi Rutherford cables, FO
M.D. Sumption,E.W. Collings,, R.M. Scanlan, S.W. Kin, M. Wake, T. Shintomi, A. Nijhuis, and H.H.J. Ten Kate, Cryogenics 41, 2001, 733
30
Coupling Loss We can compare this 10 * 104 J/m3 to the scale for the Roebel cable – No such loss slope appears –why? ? Lets calculate the coupling current, I=/R, and note that the cable would have coupled strands when most of their Ic is taken up in coupling, rather than hysteretic shielding, currents.
31
Coupling Schematic in Bean Terms
For this to be true the current flowing from strand to strand must be a relatively high percentage of the strand current, or they will flow in circles in the strands A cable has coupled strands when most of their Ic is taken up in coupling, rather than hysteretic shielding, currents Green regions are strands Black lines are flux profiles Dashed line is flux in coupled state Blue lines are uncoupled (hysteretic shielding) current Red lines are coupled current dB/dt
32
Calculating the Loss slope II
= -d/dt = AdB/dt, and dB/dt max is 0.1 Hz*4*.4T=0.16 T/s NbTi Rutherford cable A Lay pitch*cable width/2=50*15= m2 I=/R=(6*6-3V)/(2*10*10-6)= 300 A, factor of 5 or so less than NbTi Ic at measurement, strands are partially coupled YBCO Roebel A Lay pitch*slit width=1 cm * 1 mm = 1 * 10-5 m2 0.15 * 10-5 V, I = 0.15 A Since Ic for YBCO is roughly 2000 A at 4 K and low fields, a cross current I of 0.15 leads to essentially no coupling So – The hysteretic losses dominate THESE ARE EDGE LOOPS SO THE AREA IS MINIMAL
33
Summary A reminder that Roebel cables are topological transformation of Rutherford cables Current loops are directly transferrable from Rutherford after transforming FO and EO and setting R to infinity Direct I-V techniques from LTS can be used to advantge for these cables Pressure and pressure with soft metal reduce ICR, but do not give great contact. Soldering reduces ICR, but does not induce much loss because flux coupling area is small Large hysteretic losses still present
34
YBCO Splice Under Helium Flow (SUHF) Probe
A helium gas flow probe for YBCO strand and small cable has been completed and initial testing with a single tape (without splice) has been performed Studying concepts related to possible future CERN uplink See also 4LB04-G Levin Talk this conference
35
3: G-10 flow channel connection
1: Top Flange 1 3: G-10 flow channel connection 1 ¼” NPT threaded 304 S.S. Plate 2 3 Weld to 304 S.S. Sanitary Tee (Tube OD: 2 ½”) Type E TC feed-throughs sealed with Stycast 1 ¼” NPT nipple 4 2: Side Flange Support tube feedthrough (OD: ¼”) and helium gas flow to flowmeter. Stycast Bond G-10 Flow Tube (OD: 1 3/8”) Support tube with inlets for helium gas flow G-10 Sheathed 300A Current Feed-throughs Voltage/CERNOX wire feed-throughs
36
Photos of SUHF probe Mk.I
Type E thermocouples (5) Bottom Thermocouple Bottom Cernox sensor Voltage taps SIDE VIEW Kapton Tape below and above Type E thermocouple Pb-Sn Soldered onto Alloy 101 OFHC Cu plate TOP VIEW
37
Imposed Thermal Gradient Measurement
TOP BOTTOM V1 V2 V3 V4 V7 V5 V6 V11 V9 V8 V10 V12 V13 V14 TC1 TC2 TC3 TC4 TC5 3” 13.5” 3”
38
Further details - Future Work
Perform Splice experiment: Balance current transport through two tapes then transfer all to a single tape. Measuring and balancing contact resistances See talk 4LB04-By G Levin For further details