1 Avaya Online UPS 6000 VA

2 Avaya Applications Advanced power protection for:
DEFINITY Communications Systems Associated Adjunct Products Other PBX Systems Voice Mail Systems Multidesktop Environment Applications requiring extended backup time

3 Key Features Double-conversion Online Topology
Advanced Battery Management (ABM) Extended Battery Modules (EBMs) and Cabinets (EBCs) Rack/Tower Two-in-One Form Factor Standard Web/SNMP Card Hot-swappable batteries Maintenance Bypass Switch Standard

4 Complete Power Protection
The 6000 VA online UPS provides double-conversion online power protection from all 9 of the most common power problems that threaten your equipment and data Power failures High voltage spikes Power sags Frequency variations Power surges Switching transients Brownouts Harmonic distortion Line noise

5 Standard Configurations
UPS with PPDM and Optional EBM UPS with PPDM UPS PPDM UPS PPDM EBM

6 Advanced Battery Management (ABM®) Technology
B C Doubles battery service life by charging only when needed Optimizes recharge time Does not trickle charge and starve the electrolyte Intelligent microprocessor controlled - Only true & automatic battery check (periodic, controlled discharge) for most accurate advanced failure protection Sleep Feature - no unnecessary battery “drain” As with all UPSs, batteries are a critical component. ABM Plus is an effective method of extending the overall service life of the UPS.

7 ABM: 3-Stage Charger 1. Rapid recharge to approximately 90%
Restores batteries quickly UPS is ready for next power outage 2. Float charge to 100% Completely charges batteries, but prevents overcharging 3. Rest mode With charger turned off, UPS conducts accurate tests to monitor battery health and provide accurate runtime predictions

8 Extended Battery Modules (EBMs)
Add up to 4 EBMs to extend backup time Each EBM occupies only 3U of rack space Hot-swap capability allows you to increase backup time or replace EBMs while keeping attached equipment up and running Maximum number of EBMs you can connect: 700/1000 VA: 2 EBMs VA: 4 EBMs A “U” is a standard measurement of vertical rack space. 1U=1.75 inches. 3U

9 Attaching EBMs Attach EBMs with a simple daisy-chain connection
Connection to UPS Both PW EBM and PW EBM weigh 65 lb/29.5 kg each. Battery Connector for Next EBM EBM

10 Extended Battery Cabinets (EBC)
For battery backup times over two hours, up to 6 EBC240 battery cabinets can be added. UPS with PPDM EBC240

11 Battery Backup Times (In Minutes)
Extended Battery Modules (EBMs) Internal Load Batteries 1 EBM 2 EBMs 3 EBMs 4 EBMs 2000 VA/1400W 3000 VA/2100W 4000 VA/2800W 5000 VA/3500W 6000 VA/4200W Extended Battery Cabinets (EBCs) Load 2 EBCs 3 EBCs 4 EBCs 5 EBCs 6 EBCs 2000 VA/1400W 3000 VA/2100W 4000 VA/2800W 5000 VA/3500W 6000 VA/4200W Backup times are approximate and may vary with equipment, configuration, battery age, temperature, etc.

12 Rack/Tower Form Factor
The 6000 VA online UPS can be installed as a tower unit or in a standard 19-inch rack enclosure. Tower Rack

13 Rack Installation Overview
A separate rail kit is required for each module. The rail kit supports the UPS in a 19-inch rack enclosure. Mounting brackets secure the UPS to the rail kit. Left rail for PPDM UPS Mounting Brackets Left rail for PPDM PPDM

14 Web/SNMP Card The Web/SNMP card allows you to connect your UPS directly to an Ethernet network and the Internet. It allows you to monitor and manage your UPS with a standard web browser and SNMP, while simultaneously providing graceful shutdown for multiple computer systems over the network. Three extra hub ports

15 Informative User Interface
Site Wiring Fault Replace Battery (ABM technology) Self-Test Overtemperature Normal Mode (UPS On) Overload Battery Mode Load Level/ Battery Level Bypass Mode The off button shuts off power to the output receptacles, meaning that it also shuts down the connected equipment. However, to shut off the UPS completely, you must remove the line cord from the wall socket. When the unit is installed, you must press the on button before power is available at the output receptacles. For more information about selecting 100, 110, 120, or 127 Vac, read the User’s Guide. The load level graph displays the amount of load connected to UPS in normal operation and the amount of battery power remaining in battery mode. For the self-test, ABM, site wiring fault, overtemperature, and overload alerts, the corresponding LED flashes. When no alert conditions exist, the LEDs correspond to the load that is connected to the UPS. See the User’s Guide for more details. Alarm Silence/Test Button On Button (Start-On-Battery) Off Button

16 Hot-swappable Batteries
The UPS includes two battery trays that can be easily replaced without shutting down the connected equipment. Quick Replacement Instructions: Remove front panel Remove battery plate Withdraw and replace battery cartridge Battery Trays (62 lb. ea.)

17 PowerPass Distribution Modules (PPDM)
The PPDM is equipped with a maintenance bypass switch so that you can replace the UPS without shutting down the connected equipment. Four different PPDMs offer different output receptacles or hardwired input/output. 3U PPDM Bypass Switch Output Receptacles

18 PPDM Selection Guide Model Input Output Input Output Number SAP Voltage (Vac) Voltage (Vac) Connection Connections PPDM, L5-30R (1) L5-30R, (default) /120 L6-30P (8) 5-15R (1) L6-30R, PPDM, L6-30R (1) L14-30R, & L14-30R /120 L6-30P (4) 5-15R (8) 5-15R PPDM, L6-20R /120 L6-30P (1) L6-20R PPDM, HW /120 Hardwired Hardwired

19 Optional Seismic Mounting Kit
The seismic kit stabilizes the UPS in areas such as California that have earthquake safety requirements. The seismic kit holds the UPS, the PPDM, and an EBM. U-shaped brackets hold UPS in place Brackets used to bolt Kit to the floor Casters secured to base for easy movement

20 Front Panel Redundant Fans User Interface UPS (5U) Battery Trays
PPDM (3U) Bypass Switch (Normal / Bypass) Voltage Selector Switch (208/240V)

21 Rear Panel UPS Battery Breaker Web/SNMP Card REPO Port
UPS Input/Output w/PPDM EBM Connector PPDM Output Circuit Breaker PPDM Output Receptacles: (8) 5-15R Default Output Receptacle (L5-30R Default) Optional EBM Connector for Next EBM Optional Seismic Kit 6-ft. Line Cord w/L6-30P

22 SAP and PEC Codes Model SAP PEC Part Number
UPS L6-30P input Default PPDM, L PPDM, L PPDM, L6-30R & L14-30R PPDM, Hardwired EBM EBC Seismic Kit 4-Post Rail Kit