1
ReverseTap S/W MANUAL
2
Table of Contents PAGE 3 Control Panel Configuration 4
Indicator Icons & Texts on Display 5 How to Change the Mode Setting 6 Size Setting Mode / Preset Mode 7 Foam Mode 8 FOB Mode 9 Cleaning Mode / Frequently Used Shortcuts 10 Advanced Settings / Unit Mode 11 Security Mode 13 Time / Volume Mode 14 Tracking Mode 15 LED Mode / AUTOᆞManual Mode 16 ReverseTap App Mode / Keg Alarm Mode 17 Flow Meter Coefficient Mode / Cup Sensor Mode 18 Module ID Setting Mode
3
Basic Functions Control Panel Configurations Set Up Start Stop Down
Control Keypad Set Up Start Stop Down Left Right OLED Display A screen displaying the current operation status, mode selection, and various settings. 2733 mL ◎ READY 162 mL FOB on FOAM on Basic functions with button control Power OFF • Long press the Stop button, then the device will turn off with a long beep sound. • For products with a POWER switch ( ), we recommend using the POWER switch to turn off. • The 7” display is also turned off as the POWER switch. Power ON • After long pressing the Start button, the device will turn on with a long beep sound. • For products with a POWER switch, use the POWER switch ( ) to turn on. • The 7” display is also turned on as the POWER switch. Factory Reset • Long press the left and right buttons and input password. • Then all the settings will be reset after a long beep sound. Reset Amount Tracking • Long press the down button, then the total dispensed volume will be reset to zero.
4
Basic Functions READY Dispensing
Indicator Icons & Texts on OLED Display FOB on FOAM on 2733 mL READY 450 mL ① ② ⑤ ◎ ③ ④ 2733 mL Dispensing 50% 3.3 s 2745 mL Finished 100% 6.3 s 10 ℃ ⑥ ⑧ ⑦ ⑨ Stand-by status Dispensing status Finished status FOB Warning! KEG ALARM Warning! ⑩ ON : Start OFF : Stop ⑪ ⑫ FOB status FOB status Keg Alarm status 1. Dispensed Amount • This number shows how much beer was dispensed. This can be reset by long pressing Down button on Standby status. 2. Default size • The circle (◎) indicates current default size. • You can easily shift among three sizes, Small, Medium, and Large, with Up and Down button at the Stand-by status. • Default size shifting with arrow buttons only can be done in Standby-status. 3. Ready • This status indicates that you can insert the cup and dispense beer. 4. Preset Amount • This number shows the fixed amount of each preset default size (in mm). 5. ON / OFF for FOB and FOAM Mode. • This indicates the ON / OFF status of FOB and FOAM Mode. 6. Dispensing status ( ) • This signal indicates the amount of dispensed beer and the status that beer is being dispensed. 7. Percentage and time • While dispensing, the percentage and elapsed time of each beer cup is displayed. 8. Dispensing • This text indicates the Dispensing status. It notifies that beer is being dispensed. 9. Finished • This indicates the beer dispensing is complete.
5
Screen display of each Basic Mode
Basic Functions 10. FOB Mode • This text indicates the FOB status. If the sensor of the dispenser detects too much foam in the keg, it will automatically stop dispensing beer to prevent foam explosion. Normally this mode is activated when the KEG is almost empty. 11. FOB Mode • Once FOB mode is activated, after the warning signal, the display will show options between Start and Stop. 12. KEG Alarm Mode • This text notifies that KEG Alarm mode is activated. Users can set the Alarm mode to check how much beer is left in the keg. 13. Beer Temperature • This indicates the temperature of beer. ( when temperature sensor is connected ) How to change the Mode Setting • At the Stand-by status, long press the Set button enter the Mode Setting status. • Press the Set button in each mode to shift through changeable values as they blink. Once you shift through all sections, the blinking will stop. • You may change values for each blinking section by pressing Up and Down button. • Press Left and Right button to shift to the next mode. • Once all changes are complete, long press the Set button to save the changes and return to the Standby status. 1. Size-setting Mode 2. Preset Mode 3. Foam Mode 4. FOB Mode 5. Cleaning Mode Screen display of each Basic Mode SMALL 362.5 mL PRESET Press the Start twice FOB detector : ON Flow Rate x 1.30 CLEANING Press the Start twice FOAM After : 3 Times 1. Size setting Mode 2. Preset Mode 3. Foam Mode 4. FOB Mode 5. Cleaning Mode
6
Size-setting Mode screen
Basic Functions Size-setting Mode In this mode, users can change and set the discharge amount of each preset size ( SMALL / MEDIUM / LARGE ) SMALL 362.5 mL Size-setting Mode screen • Small / Medium / Large : When blinking, press Up and Down button to select any preset size. • mL : When blinking, press Up and Down button to change the numbers to set the discharge amount of preset size. Preset Mode In this mode, users can preset the preferred dispensing amount manually, and also to measure its flow rate. It also has a role to assist determining the value of FOB Mode by measuring the flow rate. PRESET Press the Start twice • Double press the Start button to run the PRESET Mode. • Press the STOP button when desired amount is dispensed. • Long press the SET button to save that amount as MEDIUM. • Pressing any other button will take you back to the initial screen of PRESET Mode. PRESET Mode is associated with FOB Mode. Therefore, PRESET Mode must be run before the very first use after installation. PRESET Mode must be run on following situations : 1. After a chiller has been switched. 2. After CO2 pressure has been changed. 3. To utilize FOB Mode properly. ※ Because the flow rate measured through PRESET Mode is used in FOB Mode, the flow rate must be measured with proper discharging of beer.
7
FOAM Basic Functions FOAM Mode
This mode is a function to control the foam amount of beer. FOAM Before : 3 times • Before : 3 times While blinking, press the up and down button to choose from “After : 5 times” to “Before : 5 times.” (After : 3 Times → This means the foam-generating action is done 3 TIMES AFTER dispensing) (Before : 2 Times → This means the foam-generating action is done 2 TIMES BEFORE dispensing) • Disable : Deactivates foam generation.
8
FOB FOB Warning! ON : Start OFF : Stop Basic Functions Detector : ON
FOB Mode (Foam On Beer Detector) When a keg is empty or just replaced, beer discharge would not be normal having foam burst out. The FOB Mode prevents this from happening. The flow rate would be faster than usual when foam is about to burst. The FOB Mode of ReverseTap detects this change and shut down the valve to prevent foam from popping. FOB Detector : ON Flow rate x 1.30 • The example screen shown above shows that the FOB Mode will be activated and shut the valve when the flow rate exceeds 1.3 times more of its usual rate. • ON/OFF : While blinking, press the Up and Down button to choose whether to use/not use this function. • Flow rate Coefficient: While blinking, input the coefficient number. (Default : 1.30) • When foam bursts while using ReverseTap, FOB Mode is activated with the screen shown below. FOB Warning! ON : Start OFF : Stop Warning screen Asking FOB Mode ON/OFF • If the FOB Detector is ON and it still cannot detect a foam popping, adjust the coefficient lower than 1.30. • If “FOB Warning” screen appears even though the keg contains a lot of beer, adjust the coefficient higher than 1.30. • Press the START button to continue FOB Mode turned ON. • Press the STOP button to turn off FOB Mode. • Things to do when “FOB Warning” is up. - If a keg is run out of beer. 1. Press the STOP button to stop FOB Mode. 2. After closing the middle valve for CO2 gas, replace a new keg. 3. Discharge all the remaining foam from a chiller and beer line until the beer is dispensed normally. 4. Turn FOB Mode ON when beer is dispensed normally. - If a keg contains enough beer 1. Rerun the PRESET Mode. (Refer to page 6 for detail use of PRESET Mode) (This is a process to reset the flow rate for proper functioning of Detector of FOB Mode.)
9
CLEANING Basic Functions
Cleaning Mode ( Use this function with a cleaning keg) This mode is to clean valves and beer line. ※ It is recommended to use this function after its daily use. CLEANING Press the Start twice • Press the START button two times and the Cleaning Mode will run with a screen saying “Cleaning Now” • Press the STOP button to terminate the Cleaning Mode. • How to use Cleaning Mode 1. Close the middle valve of CO2 gas. 2. Replace the beer keg with a cleaning Keg. 3. Open the middle valve of CO2 gas. 4. Press the START button two times to run Cleaning Mode to remove all remaining beer from beer line and chiller. 5. Run Cleaning Mode until a cleaning keg is run out of water. 6. When no more water is discharged, press the STOP button to terminate the Cleaning Mode. Frequently Used Shortcut This is a function to enter frequently used modes quick and fast. Use it in Standby status. ※ Press the buttons in the sequence below : • Cleaning Mode • Foam Mode • Size setting Mode • FOB Mode 2733 mL ◎ READY 162 mL FOB on FOAM on Standby status
10
UNITS Advanced Settings Advanced Settings Unit Mode Advanced Modes
※ Use Advanced Mode once after installation or in necessary occasions. • To access Advanced Modes : UNITS Volume : oz Temperature : ℃ Security Mode Setting Lock : ON Dispensing Lock : ON Password : **** Dispensed A 123 mL Dispensed B 345 mL VOLUME 1. UNIT Mode 2. Security Mode 3. VOLUME / TIME Mode 4. Tracking Mode ReverseTap APP STATE Not used KEG ALARM Alarm : ON Keg Volume : 50 L Warning : 30 % LED MODE State : Dispensed Mode : 2.Green AUTO 5. LED Mode 6. AUTO / MANUAL Mode 7. ReverseTap App Mode 8. KEG ALARM Mode FLOW SENSOR Coefficient : 1.15 Flow rate : 62.5 mL/s MODULE ID 1 CUP SENSOR Dual 1.Main Version : 2. Led Version : 3. Last Update : 08:00:33 Jul 9. Flow Sensor Mode 10. CUP SENSOR Mode 11. MODULE ID Mode 12. Information Unit Mode In this mode, you can choose the units to use in ReverseTap. • The volumetric units ReverseTap uses are ounce(oz) and milliliters(mL). • The temperature units ReverseTap uses are Celsius(℃) and Fahrenheit(℉). UNITS Volume : oz Temperature : ℃ • Press the Set button to select the unit and change to the desired unit with Up and Down button.
11
Security Mode Advanced Settings Settings are locked Security Mode
Setting Lock : OFF Dispensing Lock : OFF Password : **** • Setting Lock : A function to lock the settings (Foam control, LED colors, etc.). • Dispensing Lock : A function to lock the valve from dispensing even if a cup is inserted. How to use Security Mode • Turn ON Setting Lock or Dispensing Lock. • Input 4-digit password. (Default password : 1234) - Long pressing the Set button without setting any password will automatically set as default password. Thus, you may set password only if you prefer. • To save, long press the SET button. This will switch back to the Standby status. How to change the settings ( while Setting Lock is ON ) • In Standby status(Ready screen), long press the Set button. It will ask for a password with a screen “Settings are locked). Settings are locked Password : *2** • Input the correct password to enter the settings mode. - This does not change the password. This is only for entering the settings mode. - Setting Lock is continuously ON after entering password. To turn this OFF, enter the Security Mode. - If wrong password is entered, the screen will show “Incorrect password!” and return to Standby status(Ready screen). ※ To enter the Advanced settings, you may proceed as the same process above.
12
Remove the cup Advanced Settings Dispensing is locked
How to dispense beer ( while Dispensing Lock is ON ) • When a cup is inserted on Standby status (Ready screen), ‘Remove the cup’ will appear on screen. - This will continue until the cup is removed. • After the cup is removed, it will ask for a password with ‘Dispensing is locked’ screen. • After entering the correct password with a long press of the Set button, Dispensing Lock will be unlocked to enable dispensing. - If a wrong password is entered, “Incorrect password!” will appear on screen and return to the Standby status(Ready screen). Shortcuts for Security Mode • Shortcut for Setting Lock : OFF → ON - Long press the Left button on Standby status(Ready screen) to turn ON the Setting Lock. • Shortcut for Setting Lock : ON → OFF - Long press the Left button on Standby status(Ready screen) and input a correct password to turn OFF the Setting Lock. • Shortcut for Dispensing Lock : OFF → ON - Long press the Right button on Standby status(Ready screen) to turn ON the Dispensing Lock. • Shortcut for Dispensing Lock : ON → OFF - Long press the Right button on Standby status(Ready screen) and input a correct password to turn OFF the Dispensing Lock. Remove the cup Dispensing is locked Dispensing is locked Password : ****
13
TIME VOLUME SMALL SMALL Advanced Settings 5.8 s 362.5 mL 362.5 mL
Time / Volume Mode 1. TIME Mode * Used when a flow sensor is lost or malfunctioning. • Controls the dispensing amount with the duration of valve-opening time. 2. VOLUME Mode (Default) • Controls the dispensing amount with the set volume measured by a flow sensor. TIME VOLUME • TIME / VOLUME : Press Up and Down button to select one of the options. How to change the PRESET size in TIME Mode SMALL 5.8 s 362.5 mL SMALL 362.5 mL Size-setting Mode in TIME Mode Size-setting Mode in VOLUME Mode • Small / Medium / Large : Press Up and Down button to select a size. • s (seconds) : Press Up and Down button to input dispensing time for each size. - In TIME Mode, press Up and Down button to adjust dispensing time by 0.1. - Estimated volume is shown below dispensing time. Estimate volume rate : 62.5 mL / sec. - This rate is adjustable by adjusting Flow rate value (Keg Alarm Mode).
14
LED MODE LED MODE LED MODE
Advanced Settings Tracking Mode A function of showing the total amount of dispensed beer. Dispensed A 1650 mL Dispensed B mL Total amount A Total amount B • Each of Dispensed A and B can be reset. • While one of Dispensed A and B is blinking, long press the Down button to reset with a long beep. • The total amount of Dispensed A shows on top of the Standby screen. 2733 mL ◎ * Long press the Down button to reset the total amount (Dispensed A) on Standby screen. READY 162 mL FOB on FOAM on Standby status LED Mode A function of changing LED lights of before/during/after dispensing. LED is lit only when a cup is inserted in ReverseTap. LED MODE State : Before Mode : 2.Green LED MODE State : Dispensing Mode : 0.Rainbow LED MODE State : Dispensed Mode : 12.Circle • State : Press Up and Down button to select before, during, or the after (dispensing). - Before : Set LED lighting after a cup is inserted and before dispensing. - Dispensing : Set LED lighting during dispensing. - Dispensed : Set LED lighting after dispensing is complete. The lighting will continue until the cup is removed. • Mode : Press Up and Down button to select the desired color.
15
AUTO MANUAL ReverseTap APP STATE Advanced Settings AUTO / MANUAL Mode
Mode 0 : Rainbow LED Mode 1 : Red Color LED Mode 2 : Green Color LED Mode 3 : Blue LED Mode 4 : White LED Mode 5 : Blink LED Mode 6 : Yellow Color LED Mode 7 : Purple Color LED Mode 8 : Light Green Color LED Mode 9 : Light blue Color LED Mode 10 : Light purple Color LED Mode 11 : Light yellow LED Mode 12 : Circle LED Mode 13 : LED OFF AUTO / MANUAL Mode 1. AUTO Mode (Default) • Dispense the Preset amount (Small / Medium / Large) 0.5 seconds after the cup detection and stops automatically. 2. MANUAL Mode • On Manual Mode, no LED light will be lit even if a cup is inserted. • Double press the START button to start dispensing. It will automatically stop when the Preset amount(Small / Medium / Large ) is dispensed like the AUTO Mode. AUTO MANUAL • AUTO / MANUAL : Press Up and Down button to select AUTO or MANUAL. ReverseTap App Mode A function for settings when the ReverseTap App is in use. ReverseTap APP STATE Management & Analysis • Select the use of ReverseTap App. - Not used : Not in use of ReverseTap App. - Management & Analysis : Use of ReverseTap App for Management & Analysis. - Barcode : Use of ReverseTap App for Barcode System. - Remote : Use of ReverseTap App for Remote mode.
16
FLOW SENSOR Advanced Settings KEG ALARM Keg Alarm Mode
A function to alarm the user when a certain amount of beer remaining is in the keg. KEG ALARM Alarm : On Keg Volume : 50 L Warning : 30 % • Alarm : On / Off to turn on/off Keg Alarm. • Keg Volume : Input the volume of the keg. • Warning : Set the percentage of beer in keg to start the alarm. Ex) Warning : 30% An alarm starts with a warning when beer remaining the in keg is less than 30%. FLOW SENSOR Mode A function to enclose the gap between the Preset volume and the actual dispensed volume. FLOW SENSOR Coefficient : 1.15 Flow rate : 62.5 mL/s • Coefficient : Press Up and Down button to adjust the value. (Default : 1.15) - If the actual volume is more than the Preset volume : Lower the coefficient. - If the actual volume is less than the Preset volume : Raise the coefficient. ※ It is recommended to adjust from the second digit after the decimal. • Flow rate : This shows the flow rate measured in Preset Mode. (Default : 62.5mL/s)
17
CUP SENSOR MODULE ID Advanced Settings Cup Sensor Mode Module ID Mode
A function to set the number of cup sensor to use. (Single or Dual) CUP SENSOR Dual • Single : Use a single cup sensor. - Beer is dispensed when one of the cup sensors is activated. • Dual : Use two cup sensors. - Beer is dispensed when both of the cup sensors are activated. Module ID Mode A function to assign a ReverseTap ID when ReverseTap App is in use. MODULE ID 1 • Module ID : ReverseTap ID(1~8) for each ReverseTap module when using the ReverseTap App.
18
ReverseTap Customer Service
Information regarding Certified Service Center (CSC) can be collected via regional distributors and our website. ( ) Trademarks ReverseTap and ReverseTap logo are registered trademarks of NPC Co., Ltd. Other names and marks are the property of their respective owners. Refunds / Exchange / Warranty Policy Refunds or exchange may be offered within 15 days after purchase if the product cannot be used due to its defect. This does NOT apply if the customer is responsible for the damage due to one’s carelessness. NPC CO., LTD. F-5F, Innovalley 255, Pangyo-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, Republic of Korea 13486 FDA certified by SGS Webpage QR Code Copyright © 2017 NPC Co., Ltd. All rights reserved. This manual is protected under international copyright laws. No part of this guide may be reproduced, distributed, translated, or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or storing in any information storage and retrieval system, without the prior written permission of NPC Co., Ltd.