Download presentation
Presentation is loading. Please wait.
1
100% Exam Passing Guarantee & Money Back Assurance
Pass Registry Examination for Advanced Pulmonary Function Technologists (RPFT) exam in just 24 HOURS! 100% REAL EXAM QUESTIONS ANSWERS RPFT Buy Complete Questions Answers File from exam-dumps.html 100% Exam Passing Guarantee & Money Back Assurance Sample Questions
2
Question No 1: Answer: C Question No 2: Answer: B Question No 3:
In setting up a CO analyzer, a pulmonary function technologist notices that the analyzer reads -0.03 while sampling air. The technologist should? Accept the reading because it is within ± 3%. Adjust the reading to Adjust the reading to 0.00. Reverse the sample flow. Answer: C Question No 2: Which of the following is a suitable policy for following Standard Precautions in a pulmonary function laboratory? Eye protection is required when obtaining ABGs from patients with hepatitis. Reusable mouthpieces should be disposed when a patient has a history of tuberculosis. Gloves are optional when obtaining arterial blood samples using a kit Reusable mouthpieces should be disinfected between each patient. Answer: B Question No 3: During an exercise (stress) test, the minute ventilation to carbon dioxide production (Ve/VCO2) ratio is 100. This measurement indicates Severe pulmonary hypertension A normal response Equipment malfunction Increased work of breathing Answer: C Question No 4: A patient's bronchial provocation test was interpreted as positive for hyperreactive airways. Considering changes from a pre-challenge baseline, all of the following are consistent with this interpretation EXCEPT a 25% decrease in Raw. 25% decrease in FEFmax. 25% increase in FRC. 25% decrease in FEF25-75%.
3
Answer: C Question No 5: Answer: A Question No 6:
To assure linearity of an oxygen analyzer, calibrate with Three test gases within the operating range of the instrument Air C % 02 D. Two test gases within the operating range of the instrument Answer: A Question No 6: A patient is performing a flow-volume loop. A pulmonary function technologist observes equal decreases in expiratory and inspiratory flows resulting in plateaus. Patient effort is satisfactory, and he follows instructions well. The technologist should expect the patient to have a Small airways obstruction Restrictive disorder Variable large airways obstruction Fixed large airways obstruction. Answer: B Question No 7: At maximum exercise, a 24-year-old patient's heart rate is 150/min with a VO2of 750 mUmin. The calculated 02 pulse is most consistent with which of the following? Cystic fibrosis Cardiomyopathy Achievement of anaerobic threshold Deconditioning Answer: A
4
PDF Version + Test Engine Software Version
Question No 8: Which of the following is an appropriate reason to perform a multiple-breath nitrogen washout test? Measure anatomical dead space. Differentiate obstruction from restriction. Detect early small airway disease. Measure oxygen consumption. Answer: C Question No 9: When performing exercise testing on a biologic control, the measurements obtained should be compared with The patient population that will be tested. Predicted values used for the biologic control's height and weight Previous tests performed on the biologic control. At least two other biologic controls being tested. Answer: C Buy Complete Questions Answers File from PDF Version + Test Engine Software Version 90 Days Free Updates Service Valid for All Countries
5
http://www.exams4sure.com/NBRC/RPFT-practice- exam-dumps.html
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.