PROF : RAHUL CHANDEGARA
AC Bridges PRESENTED BY: HITIKXA NAKUM ( ) HITESH NANDORIYA ( ) PALAK ODEDRA ( ) NIRAJ MAHETA ( ) GUIDED BY: PROF : RAHUL CHANDEGARA
2
Hay Bridge The Hay circuit is more convenient for measuring high-Q coils Hay bridge for inductance measurements Impedance triangles illustrate inductive and capacitive phase angles for Q>10 :
3
Schering Bridge The Schering bridge, one of the most important bridges, is used extensively for the measurement of capacitors. Schering bridge for measurement of capacitance Dissipation factor :
4
Unbalance Conditions
5
Bridge balancing problem :
(a) unbalanced condition (b) bridge balance is restored by adding a resistor to arm 1 (maxwell configuration) (c) Alternative method of restoring bridge balance, by adding a capacitor to arm 3
6
Wien Bridge Applications :
Frequency measureent Notch filter Frequency-determining element Frequency measurement with the Wien bridge
7
Wagner Ground Connection
The wagner ground connection eliminates the effect of stray capacitances across the detector
8
Universal Impedance Bridge
9
Bridge configurations of the universal impedance bridge