Download presentation
Presentation is loading. Please wait.
1
Site Audit Scenario & Antenna Adjustment
ERICSSON - 4G_LTE_XL ______________________________________________ Site Id : Site Name : LTE_Komplek_TVRI Auditor / Rigger Name : Abdul Jabar patra Last Update : 21 September 2015 Site Audit Scenario & Antenna Adjustment
2
Site Audit Scenario -Antenna Physical Configuration Audit:
Site Location Feeder isolation/tapping foto Antenna Height Antenna Type Antenna Orientation Antenna Location Mechanical Tilt Electrical Tilt -Tools and Equipment: Tilt meter, Camera, Altimeter, GPS, Compass - Views: Panoramic Views every 30 degrees
3
Site Name : LTE_Komplek_TVRI Long / Lat : 106.78766 / 06.21215
Site Id : Site Name : LTE_Komplek_TVRI Long / Lat : / site id site name sec id Antenna hight Building High Type antenna Ant Direction Mec Tilt Elc tilt Before After - LTE_Komplek_Tvri 1 30m Tongyu TTB /182017/182017DE-65P 50 7 2 220 6 3 320
4
Site Name & GPS
5
BTS & Panel
6
Tower & Antenna High
7
Panoramic View 0 – 90 30 60 90
8
Panoramic View 120 150 210 180
9
Panoramic View 240 270 300 330
10
RRU Sec1 Sec2 Sec3
11
Antenna Type Sec1 Sec3 Sec2
12
Antenna View & Azimuth Before
Sec1 Sec2 Sec3 50 220 320
13
Antenna View & Azimuth After
Sec1 Sec2 Sec3 50 220 320
14
Mechanical Tilt Before
Sec1 = 1 Sec2 = 2 Sec3 = 0
15
Mechanical Tilt After Sec1 = 1 Sec2 = 2 Sec3 = 0
16
Electrical Tilt Before
Sec2 = 6 Sec3 = 7 Sec1 = 7
17
Electrical Tilt After Sec2 = 6 Sec3 = 7 Sec1 = 7
18
THANKS
Similar presentations