Force Feedback of Dual Force-Sensing Instrument for Retinal Microsurgery Computer Integrated Surgery II - Spring, 2013 Woo Yang, Seo-Im Hong, Can Wang.

Similar presentations


Presentation on theme: "Force Feedback of Dual Force-Sensing Instrument for Retinal Microsurgery Computer Integrated Surgery II - Spring, 2013 Woo Yang, Seo-Im Hong, Can Wang."— Presentation transcript:

1 Force Feedback of Dual Force-Sensing Instrument for Retinal Microsurgery Computer Integrated Surgery II - Spring, 2013 Woo Yang, Seo-Im Hong, Can Wang Mentors: Dr. Iulian Iordachita, Xingchi He, Dr. Russell Taylor Introduction Retinal microsurgery is one of the most challenging surgeries due to limited workspace and because it requires delicate movements. The Eye-Robot is a cooperative control robot being developed with the goal of assisting surgeries to make it not only efficient but also safer. There are two points of contact with the eye when inserting a surgical tool: the retina and the sclera. Novel surgical instrument measures accurate forces at these sites but the problem is real-time feedback of these forces during the surgery. Close up of the second generation eye phantom Results and Outcome We asked a few experienced eye surgeons to test out various sorbothane and rubber of hardness ranging from 30 OO to 30 A. It was determined 50 OO was closest. The glitchy robot arm haptic feedback mode resulted in the tool being rammed into the eye phantom and destroyed the tool. However from the data, we are able to conclude other methods of feedback lowered the amount of force used in experiments. Vibrotactile and auditory feedback yield similar results, which would leave the usage will be up to user preference. IRB for human subject testing was submitted 3/15/2013 but is yet to be approved. Problem Safe amount of force to be applied on the retina is < 7 mN (below human perception threshold), but robotic systems can help. The robot will read accurate forces and, with the proper feedback system, will alert the surgeon below and above safe thresholds. There are many different available methods of force feedback: auditory, vibrotactile, and robot haptic. Which one will minimize the amount of forces experienced by the eye? Solution Future Work To determine which feedback method is the most ideal, we had to set up an experiment that mimics an eye surgery. This involved developing an eye phantom. The experiment involves peeling a piece of tape from inside the phantom to mimic membrane peeling. In addition, the existing robot didn’t integrate vibrotactile mode which we implemented by interfacing the Arduino microcontroller with a small motor attached to the pedal Glitches from the robot haptic feedback should be worked out to prevent future mishaps. More fine-tuned vibrotactile motor could be incorporated to experiment with different amplitudes and faster refresh rate. Human subject testing for larger data collection. Citation X. He et al. A Novel Dual Force Sensing Instrument with Cooperative Robotic Assistant for Vitreoretinal Surgery I. Iordachita et al. A sub-millimetric, 0.25 mN resolution fully integrated fiber-optic force-sensing tool for retinal microsurgery. Int J CARS (2009) 4:383–390 Citation Core NSF CISST/ERC Thank you to our professor Dr. Taylor, our mentors Dr. Iordachita and Xingchi He, and special thanks to Marcin Balicki Left: Eye robot experiment Right: Engagement pedal with Arduino Microcontroller Engineering Research Center for Computer Integrated Surgical Systems and Technology


Download ppt "Force Feedback of Dual Force-Sensing Instrument for Retinal Microsurgery Computer Integrated Surgery II - Spring, 2013 Woo Yang, Seo-Im Hong, Can Wang."

Similar presentations


Ads by Google