Presentation is loading. Please wait.

Presentation is loading. Please wait.

California Bearing Ratio Test

Similar presentations


Presentation on theme: "California Bearing Ratio Test"— Presentation transcript:

1 California Bearing Ratio Test

2 California Bearing Ratio (CBR) :-
The ratio of the force per unit area required to penetrate a soil mass with standard penetration plunger at a uniform rate of 1.25 mm/min., to the corresponding penetration load of the standard material or crushed stone is called CBR. CBR (%) = Test load x 100% Penetration load (standard material)

3 Significance :- It is generally used to classify & evaluate the soil subgrade & base coarse materials for the flexible pavement. This test is empirical & the results cannot be accurately related with any fundamental properties of the material.

4

5 Procedure :- Take kg of soil & mix it thoroughly with required quantity of water (OMC) or field moisture content. The spacer disc is placed at the bottom of the mould over the base plate & a coarse filter paper is placed over the spacer disc. The moist soil is to be compacted over this in the mould by adopting either IS light or heavy compaction.

6 After compacting the last layer, the collar is removed & the excess of soil above the top of the mould is evenly trimmed off. The clamps are removed & the mould with the compacted soil is lifted, leaving below the base plate & spacer disc is removed. A filter paper is placed on the base plate, the mould with compacted soil is inverted & placed over the base plate& clamps are tightened. Weight of kg are placed over the soil in the mould. Then the whole mould is placed in the water tank to allow soaking for 4 days.

7 A swelling measuring device are placed on the top edge of the mould & the spindle of the dial gauge is placed touching the top of the sample. Initial dial gauge reading are recorded & the test sample is kept undisturbed in the water tank. After 4 days of soaking, the mould is clamped over the base plate & the same surcharge weights are placed on the specimen as the test could be conducted. The complete assembly is placed under the loading machine.

8 Penetration plunger is brought in contact with the top surface of the soil by applying 4 kg of load.
The dial gauge of proving ring & the penetration dial gauge is set on 0. The load is applied through penetration rate of mm/min. The load readings are taken at 0.0, 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 4.0, 5.0, 7.5, 10.0, 12.5 mm of penetration.

9 The max. load value & the corresponding penetration value are recorded.
A graph is plotted by penetration (mm) on x-axis & load (kN) on y-axis & the value of load at penetration 2.5 & 5.5 mm are found from the graph.

10

11 Finally, the CBR value is calculated from the formulae.
As per IRC recommendation the min. value of CBR required for a subgrade should be 8%.


Download ppt "California Bearing Ratio Test"