Download presentation
Presentation is loading. Please wait.
1
CYRIC beam Line (actual setup)
Router D-Link 612 Beam dump Faraday cup: Control has current readout setup (show on screen) Network (AS private): stand-alone Cat5 cable from outside C-32 to control room USB USB RJ45 panel RJ45 panel CYRIC setup Control Room USB Cat5 Stage Driver USB Cat5 USB Cat5 RS232 USB swith stage VCSEL Sample Beam monitor stage has ZnS, FC ZnS
2
Beam Monitor DAQ running on 717pu401, win7-64 with updated NI2014:
Beam Monitor DAQ running on 717pu401, win7-64 with updated NI2014: D:\suen-ds\Radhard\INER_CYRIC_2015\BeamMon_XY_Strip_FC \sampling strip\Non-BeamMonitor for TIA program_Ver FuXiong_LV2013 \BeamMon_XY_Strip_63+63(0.5mm)_CYRIC.vi (_CYRIC.vi is the copy of .vi modified at CYRIC for commnets) comments corrected for CYRIC strip map of flex cable, fit table are in (as the .vi version)
3
Motorized Stage control running on as-w7en, win7-64 with updated NI2014: D:\suen-ds\Radhard\INER_CYRIC_2015\Auto_Stage \ Stage_hou-v2.vi 12800 is the fastest to move the log show history
4
Components to be irradiated
CYRIC beam test Components to be irradiated Electronic components mounted on 100x100 mm2 Bakelite board (2mm thick ) material seen by a pass-through proton: Laser diode in TO-46 can, φ=6.6 mm: plastic holder, 50um glass, 500um GaAs, 2 mm Ceramic base, 100 um Cu can CMOS driver chips: 500 um Si chip in 4x4mm2 plastic package, on 1 mm PCB
5
Sample test, DAQ VCSEL Sample DAQ interfac GPIBUSB GM pin, cable
Octopus – MT table cable to sample DAQ interface, NI USB 6009 opt-meter VCSEL Sample TOSA samples bare-die samples 6 mA power FTM-200 optical meter ST-LC fiber 6 mA LM317 boards , USB 5V
6
CYRIC beam Line (plan) Faraday cup: Beam dump connected
Router D-Link 612 Was guessing that beam current to be setup privately Faraday cup: Beam dump connected to “Kiethley 6514”, recording current Network: stand-alone Cat5 cable from outside C-32 to control room USB RJ45 panel RJ45 panel Control Room Stage Driver RS232 USB USB Cat5 stage VCSEL Sample Beam monitor Kiethley 6514
7
Beam Line setup @INER Control Room Proton beam stage stage
Beam monitor Sample Proton beam VCSEL Sample Beam monitor USB Faraday Cup stage stage Stage Driver 6514 GPIBUSB USB Cat5 Stage Driver RS232 USB @INER USB Cat5 6514 Beam Monitor 12V DC, USB Faraday Cup Kiethley 6514 GPIB-USB Control Room Cat5 USB Router D-Link 612 Stqge tables Driver box, RS232-USB sample stands YiDa Cat5-USB USB hub D-Link 612 RJ45 cables ASUS notebooks
8
Beam Line components @INER
Beam monitor gas chambers, two sets, dimension 65x65 mm2 air gap sealed in layers of PCB. material seen by a pass-through proton: Set 1: two layers of 1mm thick PCB, with Cu strip (37 um thick) Set 2: three laysers of 1 mm thich PCB Faraday Cup @INER Laser Sample Beam monitor