Download presentation
Presentation is loading. Please wait.
1
Cedar 1-2 (row 1-2) P/T values given in mol/m^3
for the HEAD(red)/MIDDLE(green)/TAIL(blue) temperature probes. The first column shows the correlation between the temperature of the precision pressure probe (°C, x-axis) and the gas pressure (bar, y-axis)
2
Zooms: density variation of gas are shown
Cedar 1-2 (row 1-2) P/T Zooms: density variation of gas are shown They shows both increasing and decreasing trends and are not always related to pressure scans The relative variation in density is ~2.5 10^-3 While CEDAR reuirements by desing are ~10^-4
3
Cedar 1-2 (row 1-2) Insulation Factors
Obtained for the HEAD/MIDDLE/TAIL temperature probes. The values are the ratios between the maximum temperature difference inside the vessel and outside the temperature shielding for different time windows (on x-axis, hours) The shielding factor seem to be factor 3-5 while the design requirement reports a factor 20-80
4
Cedar 1-2 (row 1-2) Majorities Ratios
8/6 (red), 8/7 (green) and 7/6 (blue) Obtained by asking time differences between majorities 8,7 and 6 less than 1 second Thus they should be related to the same spill.