Presentation is loading. Please wait.

Presentation is loading. Please wait.

GSICS GDWG/GRWG Joint meeting, Toulouse

Similar presentations


Presentation on theme: "GSICS GDWG/GRWG Joint meeting, Toulouse"— Presentation transcript:

1 GSICS GDWG/GRWG Joint meeting, Toulouse
JMA’ slides Hiromi Owada (JMA) GSICS GDWG/GRWG Joint meeting, Toulouse 9-11 February 2010

2 Contents JMA’s activities after the last meeting
GSICS Correction of MTSAT IR New web page for monitoring MTSAT IR With GSICS Correction

3 JMA’s activities “GSICS Correction” and GSICS convention ATBD
after the last meeting “GSICS Correction” and GSICS convention The MTSAT IR inter calibration system has been modified to implement “GSICS Correction” and GSICS convention. The new system will be introduced into the routine. The collocation dataset and “GSICS Correction” will be sent to EUMETSAT GSICS server operationally. ATBD ATBD on the current MTSAT IR inter calibration has been completed (v.01). ATBD on the new system hasn’t been described yet (v.02).

4 JMA’s activities Product Acceptance Procedure VIS calibration
after the last meeting Product Acceptance Procedure GSICS Product Acceptance Form (GPAF) for “GSICS Correction” of MTSAT were filled out and submitted on Jan VIS calibration The development of MTSAT VIS vicarious calibration system has been completed. The system will be introduced into the routine soon.

5 GSICS Correction of MTSAT IR

6 GSICS Correction of MTSAT IR
To get corrected radiance IREF from disseminated digital count CMON by a linear regression The intercalibration result : disseminated digital count corrected Tb Tb-count table Tb Planck functions for MTSAT IR radiance corrected radiance

7 GSICS Correction of MTSAT IR
For Tb users, the table to convert disseminated digital count to corrected Tb is stored as optional information. corrected calibration table disseminated digital count corrected Tb Tb-count table Tb Planck functions for MTSAT IR radiance corrected radiance

8 GSICS Correction of MTSAT IR
Information of corrected calibration table dumped by “ncdump” dimensions: number_of_characters_in_channel_name = 3 ; number_of_channels = 4 ; number_of_selections = UNLIMITED ; // (1 currently) number_of_digital_counts_on_HRIT_table = 1024 ; variables: int number_of_digital_counts_on_HRIT_table(number_of_digital_counts_on_HRIT_table) ; number_of_digital_counts_on_HRIT_table:units = "" ; float calibration_table(number_of_selections, number_of_channels, number_of_digital_counts_on_HRIT_table) ; calibration_table:units = "K" ; calibration_table:long_name = "new calibration table created by GSICS Correction" ; calibration_table:standard_name = "gsics_calibration_table" ; calibration_table:valid_min = f ; calibration_table:valid_max = f ; data: number_of_channels = 1, 2, 3, 4 ; number_of_digital_counts_on_HRIT_table = 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, calibration_table = , , , , , , , , , , , , , , , , , , 329.2, , ,

9 New web page for monitoring MTSAT IR
With GSICS Correction

10 New web page for monitoring MTSAT IR
With GSICS Correction The sample page for routine monitoring is available on Guide Monitoring page VIS calibration

11 Guide New formula GSICS Correction of MTSAT Standard radiance of MTSAT

12 Monitoring Standard radiance CSV file

13 Monitoring Period for GSICS Correction Radiance – Digital count


Download ppt "GSICS GDWG/GRWG Joint meeting, Toulouse"

Similar presentations


Ads by Google