LEPS experiment from 2008.Jan to 2009.Jul

Similar presentations


Presentation on theme: "LEPS experiment from 2008.Jan to 2009.Jul"— Presentation transcript:

1 LEPS experiment from 2008.Jan to 2009.Jul
using the new TPC and new liquid cryo-target system 2008.Jan-Jul: 257nm laser, LH2 tagger rate ~2x105 /s 2008.Oct-Nov: 355nm laser, LD2 tagger rate ~1x106 /s Speed up DAQ by decentralizing the TPC sense-wire readout and modifying the program. Trigger: sideway + forward 2008.Dec, 2009Feb,Jul: 355nm laser, LH2 : confirm the old TPC data, calibration, etc. 2009.Mar-Jul: 355nm laser, LHe : search for the Q+ hypernuclei 2.96 GeV g LH2 ~8x1011 photons (~ old TPC run) 2.4 GeV g LD2 ~1.6x1012 photons ~2.0x1012 photons ~4.6x1012 photons

2 2008B-2009A:主な trouble & setting 変更
10/2: TPC FADC配線変更 (高速化), プログラム修正 10/9-10/11: LD2, trigger#23(TPC) [DC2Uに歯抜け not for analysis] 10/11: DC2U PA交換、TagPL hrtdc用delay 一部変更 10/12-10/16: LD2, trigger#23 10/16: replace AC(1.0081.03), set ee-veto scinti add STD trigger 10/16-10/28, 11/13-11/29: LD2, trigger#24(TPC+STD) 11/17-12/7: LH2, trigger#24 12/7: DC1U trip [12/7-12/12: DC1U無しのデータ  not for analysis] 1月~2/4: DC1修理、TOF研磨、AC交換(2枚3枚) 2/4: setting&alignment(DC1,solenoid(TPC)+NDC,FWD,TOF) 2/7-2/8: LH2, trigger#24 2/8: Solenoid OFF [2/8-2/13 solenoid 磁場無しのデータ  not for analysis] 2/13: solenoid temperature was recovered  solenoid ON 2/13-21: LH2, trigger#24 2/21: A wire of DC1V was broken (2/24,25 修理)

3 2008B-2009A:主な trouble & setting 変更
3/2: setting & alignment (DC1,solenoid(TPC)+NDC,FWD)    3/2-3/12: LHe, trigger#25(TPC/2+STD) [標的中に泡成長 not for analysis] 3/24,27: DC1再修理、レーザー系 第1、第2ミラー交換    4/6-4/22, 5/15-5/30, 6/1-6/17, 6/25-7/5: LHe, trigger STD (5/15: set rate-monitor, 6/1: replace it to new one, 6/24: reset it)    7/7-7/24: LH2, trigger#24 (7/12: solenoid quench  recover soon) 7/25-7/26: 磁場無しラン (for software alignment) 7/26-28: Cu(test), trigger#24(narrow) NB)10/15-10/28: AC1 は noisy 6/7-6/9: all DC gains were large due to incorrect gas mixture 6/28-30: peakADC of TPC anode#33 was strange 6/27-7/28: there might be a bad channel in the PADs of sector6, layer5 <Check scalers and singles histograms for all runs with modified online_ana> Summary and corrected photon numbers of each run used for analysis:

4 Correction factor for Tagger scaler
Calculate the correction factor according to Tech-note No.15 by Kohri (slightly modified) Pile-up events: |T(i)-T(j)|< T_width ( best T_width=40nsec) Correction factor : R=generated events/(generated events – pile-up events)  why?

5 Correction factor for each filling pattern

6

7 LHe run 17.73±0.51 corrected

8 LD2 run 25.15±0.38 corrected

9 LH2 run corrected 13.16±0.25

10 Data statistics Corrected tagger photon# ×DAQ live ratio
LHe(Std): x (hori 2.25x1012, vert 2.30x1012) LD2(#24/#23): 1.64x (hori 0.82x1012, vert 0.82x1012) [trig# x1012/ trig# x1012] LH2(#24): x (hori 0.93x1012, vert 1.03x1012) Luminosity (L=nb・NT    NT =rNA/A ) Scaling factor of transmission: 0.525± (from PWO data) Target density of LHe/LD2/LH2 with 15cm at boiling point 1.875 g/cm2, g/cm2, g/cm2 Luminosity: LHe 6.79x1035 cm-2 =0.679 pb-1 LD x1035 cm-2 =0.653 pb-1 LH x1035 cm-2 =0.653 pb-1 cf.) 3GeV LH2 (~0.8x1012x0.532)x(1.062xNA/A) = 0.27 pb-1

11 Check pedestal files (miho:/np1b/v04/sp8lep/ntpc/pede/)
pedestal_mean Run# ・ remove some strange runs  (not junk runs in the log-note) ・ ch1253 (Preamp79, ch 5) shows 2 lines. (sector 6, layer 7, 3rd pad)

12 NTPC gain correction with cosmic-ray data cut: |dip angle|<15°
-1717<z<-1517 Pad (peakAdc) vs wire sum  good S wihi /S wi w-2=w2= w-1=w1= w0= 読んでいない両端のWire は  1番目と27番目のwire の x0.5 が良い

13 z-dependence of Pad gain
x y z (-25<x<25) (-1717<z<-1517)