Presentation is loading. Please wait.

Presentation is loading. Please wait.

Scott MacLeod UL LLC TC 111 US NC

Similar presentations


Presentation on theme: "Scott MacLeod UL LLC TC 111 US NC"— Presentation transcript:

1 Scott MacLeod UL LLC TC 111 US NC
111/461/CD Compilation of Comments Summary & IEC Development Update IEC TC111 PT th Face-To-Face Meeting Otemachi 1st Square, East Tower 2nd floor, Room D, Otemachi, Chiyoda-ku, Tokyo, Japan October 31 – November 2, 2017 Scott MacLeod UL LLC TC 111 US NC

2 Report of Comments on 111/461/CD (“CD2”)
P-members O-members Non-members Total Y : comments received 15 N : no comments 8 5 2 - : no response 7 9 Comment Closing Date Was September 15, 2017 Comments Provided By15 Voting Member Countries (BE, CA, CN, FI, FR, DE, IE, IT, JP, NL, NO, ES, SE, UK, US) One Technical Committee (TC47) Provided Comments None From 8 Voting Member Countries (BR, CR, DR, DK, IN, KR, MA, TH) 305 Comments in Total 156 Technical 101 Editorial 29 General

3 111/461/CD Summary of Significant Comments
Based on Two or More NC Responses Indicating: Remove 0.9% Limit Remove Criteria 3 Keep 0.9% Limit & Criteria 3 Change Title (“Low Halogen Materials of Concern”) Make “TR” General Opposition Favor Two Classes Exclude Fluorine & Iodine Remove 0.9% Limit & Criteria 3 446_CC_111_446_CD.doc

4 Summary of Comments to Document 111/461/CD (2/4/17)
NC / Item Remove 0.9% Limit Remove Crit. 3 Keep 0.9% & Crit. 3 Change Title (“ Concern”)  Make “TR” Generally Oppose Favor Two Classes Exclude F & I Remove 0.9% & Crit. 3 Belgium X X* Canada China Finland France Germany Ireland Italy (X) Japan X1 X2 X3 NL Norway Spain Sweden UK USA TC47 % of NC’s 67 33 27 20 13 * = Only include Criteria 1 (X) = Wants a summation limit of 0,9 % for Cl and Br only. X1 = Raw material suppliers want to keep, article suppliers want to remove X2 = Raw material suppliers want to remove, EEE product manufacturers want to keep X3 = Some want a two level definition, DB Criteria 1,2&3 as “LH Basic” and Summation limit with DB Criteria 1,2+3 as “LH Advanced”. Others don´t want a two level definition.

5 Other Trending 461/CD Comments
Clarify IEC Version Reference (NO, SE, BE, US, GB, IE, TC47) Clarify Scope Regarding Gas, Liquid & Solid (JP, TC47, US, GB) Understanding of TC111 “Environmental” Scope – Human Health?, Combustion Products?, Toxicity? & Safety? (GB, NL, ACEA) Low Halogen Defined in Other Standards (BE, TC47, US) Liaise with ISO TC61 (DE & ES)

6 IEC 62321-3-2 Development Update
“Screening of fluorine, chlorine, bromine and iodine in polymer and electronics by Combustion – Ion Chromatography (C-IC)” CDV Drafted and Initial International Inter-laboratory Study (IIS) is Completed! Document Circulation Date Closing Date Result 111/385/NP - 111/398/RVN Approved 111/418/CD ~ 100 Comments 111/450/Q 111/454/RQ Approved to Add Iodine

7 3-2 International Inter-laboratory Study (IIS)
Initiated (Samples Sent to Labs) in March of 2017 Four Samples Included Varying Amounts of F, Cl, Br & I 20 Laboratories Invited 7 Laboratories Accepted 6 Laboratories Have Returned Results

8 IIS 3-2 Fluorine Sample B02 Results show good correlation to the expected value Sample D04 No F expected but reported by all labs (less than 0,02%)

9 IIS 3-2 Chlorine & Bromine
Results show good correlation to the expected values

10 IIS 3-2 Iodine 2 results are good 1 result is acceptable
3 results are too low

11 IIS 3-2 Conclusions Results for F, Cl, and Br were good
Results for F in sample IIS3-D04 need further investigation as no F was expected. Results for I were low / inconsistent More lab data is needed A second IIS incorporating new samples and methodology to account for low / inconsistent iodine.

12 Scott MacLeod UL LLC TC 111 US NC
111/461/CD Compilation of Comments Summary & IEC Development Update Discussion Scott MacLeod UL LLC TC 111 US NC