Presentation is loading. Please wait.

Presentation is loading. Please wait.

Neutronics Studies for the Nab Experiment

Similar presentations


Presentation on theme: "Neutronics Studies for the Nab Experiment"— Presentation transcript:

1 Neutronics Studies for the Nab Experiment
By Elizabeth Mae Scott for the Nab Collaboration Nab: A search for “a” and “b” Dose Plot The Nab experiment aims to measure the beta decay products of unpolarized neutrons to determine the electron-neutrino correlation coefficient “a” and the Fierz interference term “b”. The electron-neutrino correlation will be measured using the proton time of flight (TOF) and the electron energy of each beta decay. Knowing electron energy Ee and proton momentum pp, we can extract all three momenta. Alternating SS and borated poly shielding SS and borated Poly Roof shielding Lead shielding pe pp FnPB: Fundamental neutron Physics Beamline θev Beam Stop Fiducial Decay Volume pv Lead shielding Rad/hour Lower Detector Coincidence Signaling Compared to the electrons and neutrinos, protons are much more massive, and therefore have a relatively low recoil kinetic energy at approximately .3 keV. To be more easily detected, they are accelerated via a 30 V potential difference between the decay volume and the upper Si detector. The detected electrons will have a kinetic energy range of keV. Setting a trigger limit of 30 keV, we first look for an electron signal in the keV range. Because the protons are low energy, they are difficult to distinguish. We take advantage of coincidence timing to signal a decay. If an electron in the expected energy range is detected, we then look for the corresponding proton. We expect to see the proton within microseconds after the electron signal. Background Results Current collimation and geometry gives a decay rate of 1833 Hz for a cylindrical decay volume with height 8 cm and radius 2.7 cm. Background rates were found for the 1) the inner 8 cm diameter disk and 2) the outer 15 cm diameter ring of the Si detectors. Lower Detector Background Rate (Hz) Upper Detector Deposited Neutrons Deposited Gammas No Shielding 830 2423 15404 45993 115 2678 6806 Optimized Shielding 145 233 Background Reduction Due to the 30 V potential difference, proton detection is only in the upper detector. This detectors sees about 1/8th of the total protons produced- giving only 200 protons per second for the upper detector. About 98% of the electrons corresponding to these protons reach a detector, therefore the coincidence signal is approximately 200 Hz. Slow neutron capture in materials in the beam line isotropically emits gammas and neutrons. If these products deposit similar energies in the Si detector as the protons within the time window after a detected electron, they give a false coincidence. The probability of a false coincidence is scaled by the time window- a background rate on the order of 103 Hz and a time window of 3 x 10-5 s will give a false background rate of about 3 x 10-2 Hz. The uncertainty σa is proportional to 1/√N, where N is the number of decays observed. Reducing the background rate and thereby the statistical error will help to give a larger uncertainty budget for systematic errors. The shielding must reduce the number of background singles events so that the rate of false coincidences is low compared to our true signal. A one to one ratio of background single events to decays gives a statistical error on the order of 10-4. Conclusion The greatest source of background was neutron capture in aluminum windows. Lead shielding and alternating layers of SS and borated polyurethane effectively shielded this. Additional background was reduced by lining the beam line with Li6 to avoid neutron capture on surrounding materials. Current shielding design gives an acceptably low background rate of ~ 400 Hz in the lower detector only. This significantly reduced background in both the upper and lower detectors. However, the dose plot shows that roof shielding allows for a leak in dose near the magnet. This roof shielding design is still in progress and the dose will be taken into account in its design. Methods and Materials Geometry and neutronics behavior were modeled using Monte Carlo N-Particle 6 (MCNP6) Background rates were approximated by the reaction rate of the incident particle in a slab of silicon 15 cm in diameter and 2 mm thick. Gamma shielding included lead and stainless steel Neutron shielding included borated polyurethane and Li6


Download ppt "Neutronics Studies for the Nab Experiment"

Similar presentations


Ads by Google