Download presentation
Presentation is loading. Please wait.
Published byProsper Fleming Modified over 6 years ago
1
TIB module performance at X5 Test beam – preliminary studies
G.Segneri et al. Universita` and INFN - Pisa Test Beam meeting – October
2
Outline Detector behavior under different bias voltages
Studies on Detector Response Uniformity
3
Voltage scan for TIB Detectors
Study of the detector properties (noise, charge, S/N, cluster width and response function) as a function of the applied voltage Used runs: TIB peak: 1198, 99, 1202, 03, 04, 14, GeV m TIB dec.: 30020, 24, 27, 33, 36, 39, 42, 46 – 120 GeV p, 25 ns beam
4
Beam Position in TIB Modules
muon beam pion beam
5
TIB Voltage scan -peak Peculiar behaviour at 300 V – hysteresis effect?
6
TIB Voltage scan – peak (II)
7
TIB Voltage scan – dec.
8
TIB Voltage scan – dec. (II)
20% increase in S/N ratio for Vbias = 2Vfd
9
Response Function
10
Cluster Shape Dec. mode Vbias=200V Peak mode Vbias=200V Peak mode
11
TIB Voltage scan under controlled environmental conditions
p beam T<23 oC Run numbers: T<23 oC: 30133, 37, 40, 42, 45, 47, 50 R.H.<20%: 30154, (62-66), (69-74) 120 GeV muon beam
12
TIB Voltage scan under controlled environmental conditions (II)
Performance reproducible under controlled RH condition signal and noise depend on RH but not their ratio
13
Voltage Scan for TOB Detectors
Used runs: 30145, 47, 51, 63, 64, 65 – 120 GeV m, 25 ns beam – deconvolution mode
14
TOB mod # 7 TOB mod # 8 TOB mod # 9 TOB mod # 10 TOB mod # 11 TOB mod # 12
15
TOB Voltage scan Noise constant above 200 V
Charge collection improvement at very high voltage
16
TOB module voltage scan (II)
25% decrease in S/N for Vbias = Vfd
17
TOB module voltage scan (III)
Less 10% of charge loss at Vbias/Vdepl>1.5 Constant cluster width above Vbias=300 V
18
Comparison TIB/TOB 95% of S/N highest value at 1.7 (1.5) Vdepl for TOB (TIB) modules
19
Sensor Uniformity Studies
Study of the TIB sensor properties (noise, charge, S/N, respone function) as a function of the cluster position Used runs: Run : peak mode, pion beam, approx. 500,000 events Run 1484: dec mode, 25 ns pion beam, approx. 1,500,000 events
20
Groups of 16 strips
21
Groups of 8 strips Groups of 16 strips
23
Conclusions TIB and TOB modules behave as expected except
in some runs to be understood Dependence on RH to be investigated more deeply (next talk?) Uniformity of detector performance as a function of the position was successfully tested in high statistics runs Work still in progress…
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.