Download presentation
Presentation is loading. Please wait.
Published byCarmel James Modified over 6 years ago
1
Solving Bearing Misalignment Issues for STP Feed Pumps
STP - James Alston, System Engineer Sulzer Pump - Art Washburn, PE Pioneer - Lyle Branagan, PE EPRI FSRUG - San Antonio, TX February 2011 Copyright 2009 Pioneer Motor Bearing Company
2
Sulzer 22 x 22 x 17 CD 1 Stage Horizontal Pump
3
Out-board Bearing
4
In-board Bearing
5
Pump Side View (Thrust End)
6
STP FW Pump Design Vintage, 1978 Service, Steam Generator Feed Water
15, FT 5420 RPM SG 0.88 (Temperature, 373 deg F) Horsepower, 10,000 BHP (max) Bearing L/D Ratio, 0.72
7
Performance Curve (Multistage)
8
Performance Curve (Certified)
9
Performance Curve (NPSHR Knee)
10
Misalignment Damage on Pump Sleeve Bearing
Upper half Damage found on the pump bearing due to misalignment with the turbine. Lower half Turbine side Turbine side Investigated October 2005
11
Observed babbitt fatigue damage
Damage due to cyclic stresses from vibration. Can also be due to misalignment or looseness forces.
12
Alternative Pump Bearings
Want to handle wide range of misalignment Accompanied by wide range of bearing loads Tilting pad design handles load range Select pivot for best misalignment accommodation Design misalignment 0.058”
Similar presentations