Download presentation
Presentation is loading. Please wait.
Published byAnn Higgins Modified over 6 years ago
1
Electronics: Principles and Applications Eighth Edition
(Instrumentation Labs) Charles A. Schuler Lab 1 Introduction to the Function Generator and DMM McGraw-Hill ©2013 by The McGraw-Hill Companies, Inc. All rights reserved
2
A generator provides its calibrated output voltage when RL = RI.
VRMS RL RI 20 VPP 10 VPP RI = 50 VRMS = 0.707 VPP 2 = V For a sine wave:
3
The open-circuit (unloaded) voltage is higher.
The DMM’s resistance (RM) is very high and the generator is essentially unloaded. RM = 10 M 20 VPP 20 VPP (7.07 VRMS)
4
Measuring the dc voltage drop across RB
RA RC VOLTMETERS ARE CONNECTED IN PARALLEL.
5
This DMM has auto polarity.
RB RA RC
6
Measuring the current through RC
3 3. Select DC I 1 1. Use I jack 2 2. Press Shift RA 4. Break the circuit RC RB AMMETERS ARE CONNECTED IN SERIES.
7
W Measuring resistance RA RC RC RB
DO NOT MEASURE RESISTANCE IN LIVE CIRCUITS!
8
Function generator and DMM Quiz
A calibrated signal generator will produce an output equal to its amplitude setting only when the load is equal to RI The open-circuit output amplitude is always ___________ than the amplitude setting. greater than Voltmeters are connected in parallel Ammeters are connected in series Ohmmeters are never connected to live circuits