Download presentation
Presentation is loading. Please wait.
Published byWillis Bond Modified over 6 years ago
1
ATLAS Upgrade Module Bonding Trials Using Glass Asics
Fred Doherty, Joe Ashby, Fiona McEwan & Calum Gray Infrastructure & issues and solutions for ATLAS Upgrade Hybrid/Module strip bonding ATLAS Upgrade Module Bonding Trials Using Glass Asics 1 1
2
130 nm ATLAS Upgrade Module
BJ820 Bonding Setup 19th January 2016 GU Meeting 2 2 2
3
130 nm ATLAS Upgrade Module
ATLAS Upgrade Module with Glass Readout Asics 19th January 2016 GU Meeting 3 3 3
4
130 nm ATLAS Upgrade Module
Glass Readout Asics with 4 rows of metal bond pads 19th January 2016 GU Meeting 4 4 4
5
1st 130nm glass asic module bonding
The Front End Bonding (FEB) software program was loaded and the XY positional re-referencing, pattern recognition and Z height adjustment for all 10 glass asics on the hybrid and silicon strip sensor were performed. All bond pads checked for correct alignment, metallisation, dirt, debris (bond position moved if possible from problem areas). All 10 asics checked with (64) 256 bond wires requiring (128) 512 bonds per asic (Source - asic & Destination – sensor) and giving a total of (640) 2560 bond wires requiring (128) 5120 bonds in total for LH hybrid. All glass asic bond pad welding parameters had to be modified from the original program settings. The existing parameters would not take to the glass asic pads in trials - deformation error (too small) - so changed (increased weld parameter settings). Prepare wire for immediate bonding using trial bonds if problem stop during 1280 bonds have to understand and fix error, sort and prepare wire to continue bonding. All 10 glass asics bonded well with new parameters and after successful completion of the LH hybrid to sensor bonds the module sensor was rotated to continue RH hybrid to sensor bonds. Checks on all bonding info including BJ820 individual wire bond graphs & detailed visual inspections confirmed successful completion. This procedure is only 1/8 of the FE Bonding for 1 module. 19th January 2016 GU Meeting 5 5 5
6
1st 130nm glass asic module bonding
Wire bond positions on ‘destination pads’ of silicon strip sensor 19th January 2016 GU Meeting 6 6 6
7
1st 130nm glass asic module bonding
The many parameters for wire bonds (source / destination) at any (Asic / sensor) referenced position 19th January 2016 GU Meeting 7 7 7
8
1st 130nm glass asic module bonding
There are 3 options for a bonding program procedure: Load 1st bond wire layer program then bond both sensor hybrids (markings on sensor when rotating with suction tool 4 times for 4 wire layers). Fully bond the one sensor hybrid loading 4 layer programs and then 1 rotation and load 4 programs to complete other side. Create 4 program for 4 bond layer to complete both sides. Hybrid/Sensor Positional accuracy and repeatability may cause problems and added time setting up. Referencing and Pattern Recognition also for 20 rather than 10 in current smaller logical program. Ideally we do not want to be rotating / moving the sensor at any stage in the bonding process so the 4 programs covering each layer for both sides will I’m sure be implemented. 19th January 2016 GU Meeting 8 8 8
9
1st 130nm glass asic module bonding
First LH Hybrid wire layer 1 fully bonded 19th January 2016 GU Meeting 9 9 9
10
1st 130nm glass asic module bonding
19th January 2016 GU Meeting 10 10 10
11
1st 130nm glass asic module bonding
19th January 2016 GU Meeting 11 11 11
12
1st 130nm glass asic module bonding
19th January 2016 GU Meeting 12 12 12
13
1st 130nm glass asic module bonding
This is a recorded video of the actual wire bonding after preparatory stage. 19th January 2016 GU Meeting 13 13 13
14
1st 130nm glass asic module bonding
Preliminary conclusions Good learning curve and experience gained for 130nm Module bond phase. A few issues identified but no show stoppers. CNM glass asics and silicon sensor bond very well at set welding parameters. Timing of all procedures cannot be tied down. Program expansion to 2 hybrids likely. Loop heights for wire layers look ok but electrical module required to confirm. Bond pull test not required till proper asics available for trials. Will look for a camera / microscope lense screw adaptor for videoing setup. Will feedback to UK bonders group on experience so far. 19th January 2016 GU Meeting 14 14 14
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.