1
RF Status 1 4 High Power Amplifier circuits available CERN(2)
one working at 88MHz One in pieces, one working spare for linac Berkeley(2) as yet seen – visit planned last week of August Some information – not without cost…. Cost of New Amplifier ~ 70k
2
PAC 1991
3
RF Status 2 TH271 Drivers – amplifiers & tubes available at CERN (4-5)
4616 Drivers available at Los Alamos (4) Currently in use – expected ?
4
Possible Schemes 8x 1MW Option 4x 3MW Option
One amplifier chain per cavity Lack 4 Amplifier circuits 4x 3MW Option One amplifier shared to two cavities Need load and circulator per cavity Assumes 4 amplifier circuits reused
5
4x 3MW CAVITIES LOAD 1 to 1.5 MW 100 to 150 kW TH116 4616 LOAD MATCHED
POWER SPLITTERS 1 to 1.5 kW R.F. DRIVE LOAD TH116 4616 LOAD 70db COUPLERS CIRCULATORS R.A.CHURCH R.A.L.
6
8x 1MW CAVITY 1 kW 10 mW 1. To 1.5MW 100 kW 70db COUPLER TH 116
AMPLITUDE AND PHASE CONTROL 4616 SOLID STATE DRIVER R.F. SOURCE R.F. SOURCE TO SEVEN OTHER PHASE AND AMPLITUDE CONTROL SYSTEMS R.A. CHURCH R.A.L.
7
Costs
8
£ Cost comparison 8x Option 4x Option 4 new circuits ~ 280k
4 extra 4616 tubes ~120k Extra controls etc ~200k = 600k 4x Option 8 circulators, ~480k 8 loads ~80k 4x splitters ~16k = 576k
9
Suggested Plan Choose 8x option - Build in two phases Phase I Phase II
Initially re-use available kit Power 4 x 1 MW into 4 cavities ~ 1000k est Phase II Construct new circuits Power 8 x 1 MW into 8 cavities