Download presentation
Presentation is loading. Please wait.
1
NobelProcera™ Implant Bridge
Location, date Presenter name Disclaimer: Some products may not be regulatory cleared/released for sale in all markets. Please contact the local Nobel Biocare sales office for current product assortment and availability. 322 Library_NobelProcera Implant Bridge – Introduction_Feb 2012
2
NobelProcera™ Implant Bridge Zirconia
Indications: Implant or multi-unit abutment level All indications Bridge 2-10 units to fit in a disc 60mm x 30mm (white/shaded) Bridge units to fit in a disc 62.5mm x 30mm (white) and 62.5mm x 20mm (shaded) Available in four shades: white, light, medium and intense Contraindications: Cases where the mesial/distal cantilevers have a length of more than one unit. Cases with a pontic span exceeding the maximum limit between the supporting implants Refer to NobelProcera Zirconia Fact Sheet for detailed information
3
NobelProcera™ Implant Bridge Zirconia
Platform Options for Zirconia Implant Level and Abutment (multi-unit) Level: NobelReplace Tapered & Straight, NobelSpeedy Replace, Replace Select Tapered (NP, RP, WP, 6.0) Replace Select Straight (NP, RP, WP) NobelReplace Platform Shift (NP, RP, WP) Brånemark System, NobelSpeedy (NP, RP, WP) NobelActive, NobelReplace Conical Connection (NP, RP) Abutment (multi-unit) Level only: Straumann Bone Level (NC, RC) Straumann Standard/Standard Plus (4.8, 6.5) AstraTech (Yellow, Aqua, Lilac) AstraTech (ST 3.5, ST 4.0, ST 4.5/5.0) Camlog (3.3, 3.8, 4.3, 5.0/6.0) Ankylos (3.5, 4.5, 5.5, 7.0) Straumann® is a registered trademark of Institut Straumann AG, AstraTech® is a registered trademark of AstraTech Group, Camlog® is a registered trademark of Camlog Biotechnologies Group, Ankylos® is a registered trademark of Dentsply Friadent Group. Disclaimer: Some products may not be regulatory cleared/released for sale in all markets. Please contact the local Nobel Biocare sales office for current product assortment and availability.
4
NobelProcera™ Implant Bridge Zirconia
1a Implant level impression Place impression copings onto the implants and take an implant level impression. Connect the temporary restoration or healing abutment and send the impression to the laboratory. Note: For impression, use Impression Coping Bridge Open Tray Conical Connection. 1b Abutment level impression Place the Impression Coping Multi-unit on the Multi-unit Abutments. Connect the temporary restoration or healing cap and send the impression to the laboratory. Disclaimer: Some products may not be regulatory cleared/released for sale in all markets. Please contact the local Nobel Biocare sales office for current product assortment and availability.
5
NobelProcera™ Implant Bridge Zirconia
2 Laboratory procedures A model is made and a resin framework fabricated. These are then scanned using NobelProcera Scanner and sent to a NobelProcera production facility. The framework is milled from a pre-sintered block of zirconia, sintered to full density and sent to the laboratory for veneering. Disclaimer: Some products may not be regulatory cleared/released for sale in all markets. Please contact the local Nobel Biocare sales office for current product assortment and availability.
6
NobelProcera™ Implant Bridge Zirconia
3 Connection of final restoration Ensure that the implants are free from any soft tissue or bone remnants. Connect the restoration to the implants with abutment screws using the Screwdriver Unigrip. Starting with the implant nearest to the middle of the bridge, tighten the remaining screws, alternating left and right sides. Tighten the abutment screws to 35 Ncm using the Manual Torque Wrench Prosthetic and Screwdriver Machine Unigrip. Fill the screw access holes with a suitable material (such as gutta- percha, silicone, or temporary filling material as a first layer to protect the screw head, followed by a e.g. restorative composite) Notes: Abutment screws must be ordered separately. A radiograph can help to confirm accurate seating of the restoration. When using NobelProcera Implant Bridge with external connection to compatible hex implants, use screw intended for the Brånemark System platform. Disclaimer: Some products may not be regulatory cleared/released for sale in all markets. Please contact the local Nobel Biocare sales office for current product assortment and availability.
7
NobelProcera™ Implant Bridge Titanium
Indications: Implant or multi-unit abutment level All positions in the mouth Maximum dimensions: 95 x 70 x 30 mm (Length x Width x Height) 2-14 units Contraindications: Cases where the mesial/distal cantilevers have a length of more than two units Cases with a pontic span exceeding the maximum limit between the supporting implants
8
NobelProcera™ Implant Bridge Titanium
Platform Options for Zirconia Implant Level and Abutment (multi-unit) Level: NobelReplace Tapered & Straight, NobelSpeedy Replace, Replace Select Tapered (NP, RP, WP, 6.0) Replace Select Straight (NP, RP, WP) NobelReplace Platform Shift (NP, RP, WP) Brånemark System, NobelSpeedy (NP, RP, WP) NobelActive, NobelReplace Conical Connection (NP, RP) Abutment (multi-unit) Level only: Straumann Bone Level (NC, RC) Straumann Standard/Standard Plus (4.8, 6.5) AstraTech (Yellow, Aqua, Lilac) AstraTech (ST 3.5, ST 4.0, ST 4.5/5.0) Camlog (3.3, 3.8, 4.3, 5.0/6.0) Ankylos (3.5, 4.5, 5.5, 7.0) Straumann® is a registered trademark of Institut Straumann AG, AstraTech® is a registered trademark of AstraTech Group, Camlog® is a registered trademark of Camlog Biotechnologies Group, Ankylos® is a registered trademark of Dentsply Friadent Group. Disclaimer: Some products may not be regulatory cleared/released for sale in all markets. Please contact the local Nobel Biocare sales office for current product assortment and availability.
9
NobelProcera™ Implant Bridge Titanium
1a Implant level impression Place Impression Copings onto the implants and take an implant level impression. Connect the temporary restoration or healing abutment and send the impression to the laboratory. Note: For impression, use Impression Coping Bridge Open Tray Conical Connection. 1b Abutment level impression Place the Impression Coping Multi-unit on the Multi-unit Abutments. Connect the temporary restoration or healing cap and send the impression to the laboratory. Disclaimer: Some products may not be regulatory cleared/released for sale in all markets. Please contact the local Nobel Biocare sales office for current product assortment and availability.
10
NobelProcera™ Implant Bridge Titanium
2 Laboratory procedures A model is made and a resin framework fabricated. These are then scanned using NobelProcera Scanner and sent to a NobelProcera production facility. The framework is milled from a solid, biocompatible, monobloc of titanium and sent to the laboratory for veneering. Disclaimer: Some products may not be regulatory cleared/released for sale in all markets. Please contact the local Nobel Biocare sales office for current product assortment and availability.
11
NobelProcera™ Implant Bridge Titanium
3 a Connection of final restoration on implant level Ensure that the implants are free from any soft tissue or bone remnants. Connect the restoration to the implants with abutment screws using the Screwdriver Unigrip. Starting with the implant nearest to the middle of the bridge, tighten the remaining screws, alternating left and right sides. Tighten the abutment screws to 35 Ncm using the Manual Torque Wrench Prosthetic and Screwdriver Machine Unigrip. Fill the screw access holes with a suitable material, such as gutta-percha, silicone, or temporary filling material. Notes: Abutment screws must be ordered separately. A radiograph can help to confirm accurate seating of the restoration. When using NobelProcera Implant Bridge with external connection on compatible hex implants, use screw intended for the Brånemark System platform. Disclaimer: Some products may not be regulatory cleared/released for sale in all markets. Please contact the local Nobel Biocare sales office for current product assortment and availability.
12
NobelProcera™ Implant Bridge Titanium
3 b Connection of final restoration on abutment level Connect the restoration to the abutments (Multi-unit Abutments) with prosthetic screws. Starting with the implant nearest to the middle of the bridge, tighten the other screws, alternating left and right sides. Tighten the prosthetic screws to 15 Ncm using the Manual Torque Wrench Prosthetic and Screwdriver Machine Unigrip. Fill the screw access holes with a suitable material, such as gutta-percha, silicone, or temporary filling material. Notes: Abutment and prosthetic screws must be ordered separately. A radiograph can help to confirm accurate seating of the restoration. 15 Ncm Disclaimer: Some products may not be regulatory cleared/released for sale in all markets. Please contact the local Nobel Biocare sales office for current product assortment and availability.
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.