Some random thoughts on dish antenna experiments
Marek Kowalski Universität Bonn
2
10-6 Hz 10-8 Hz
4
Sensitivity With increasing A and constant angular reslution,
Horns et al., JCAP 2013 With increasing A and constant angular reslution, the dimensions of the image, as well as the detector noise increases linearly.
5
Example for a 20 cm f/4 dish @ 500nm
PSF width (diffraction limited): 1.2 x f/8 x λ = 5 μm Focus spot size: 4 x (f/8)2 x λ = 128 μm Alligment light source at center of dish Allignement should not to be a problem Possible sensors: CCD, TE sensor or PMT?
6
Wide Field Camera 3 on the Hubble Space Telescope
High quality, substrate-removed 1.7 μm HgCdTe arrays delivered to Goddard Space Flight Center Dark current (145K) = 0.02 e-/pix/sec Readout noise = 25 e- (single CDS)
7
Beletic
8
Photomultipliers Disadvantages: Limited wavelength range Advantages:
Large size! Noise ~1 Hz per cm2 area (cooled to <-10oC) Possible variation: Light concentration through wavelength shifting lightguides, readout by small PMTs. Noise reduction by factor ~100 possible (development done in Bonn) Similar technique as in solar luminiscent concentration
9
Photomultipliers Disadvantages: Limited wavelength range Advantages:
Large size! Noise ~1 Hz per cm2 area (cooled to <-10oC)
10
Transition Edge sensors
Pros: Single photon sensitivity Limited energy information per photon Low noise (10-3 Hz or lower?) Disadvantages Limited Size Complicated operation
11
Figure of merit Example 1: Example 2: Adish = 0.2 m2 (0.5 m diam)
Adetector = 200 μm2 Ndark = 500 Hz (using CCD) T=107 s FoM = Example 2: Adish = 7 m2 (3 m diameter) Adetector = 1 cm2 (~1 arcmin FoV) Ndark = 1 Hz (using PMT) T=107 s FoM =