Data acquisition and data processing software for magnetic measurements for NICA magnets Alexander Bychkov LHEP, JINR 2017.

Similar presentations


Presentation on theme: "Data acquisition and data processing software for magnetic measurements for NICA magnets Alexander Bychkov LHEP, JINR 2017."— Presentation transcript:

1 Data acquisition and data processing software for magnetic measurements for NICA magnets
Alexander Bychkov LHEP, JINR 2017

2 Contents Main Measurement Program
Filtering and smoothing system based on wavelets and splines

3 Measurement test bench
Computer Rack Cabinet Controlled Power Supply

4 Main Measurement Program

5 System Characteristics
Automated system (minimal operator actions) Cold and warm measurements 24-bit ADC/DAC samples/s per channel Saving data - RAW Sensor positioning <1⋅10-4 220 steps/rot

6 Signal form and Data acquisition
NI DAQmx chassis base signal Synchronized DACs data Synchronized ADCs execution Main Measurement Program LabView triggering triggering

7 Sensor position management
Main Measurement Program LabView LAN Real-Time controller EtherCat Servo drive Sensor position

8 Functions of Main Measurement Program
base signal Synchronized DACs NI DAQmx chassis data Synchronized ADCs base signal execution triggering Current supply triggering data Main Measurement Program LabView current impulse COM GPIB Sensor coils switch Magnet coils switch LAN Real-Time controller data GPIB Current Supply controller Sensor EtherCat position Servo drive Superconducting Magnet

9 Measurement data collection
Measurement Data flow Data storage Temporal files Preprocessing data Filtering Smoothing Integration Measurement data collection Processing data Results

10 Wavelet peak detection
Preprocessing data Complex noise Minimal noise Wavelet filtering Wavelet peak detection Spline smoothing Integration Integration

11 RAW data I(t)

12 Power spectrum

13 Wavelet filtration I(t)

14 Peak detection (wavelet)

15 Spline smoothing

16 Comparison: RAW and filtered data (1)

17 Comparison: RAW and filtered data (2)
Average error ~10-6 Worst situation error ~10-3