Presentation is loading. Please wait.

Presentation is loading. Please wait.

Stop Check Valve Used in Ammonia Refrigeration System Manufactured by Maniks

Similar presentations


Presentation on theme: "Stop Check Valve Used in Ammonia Refrigeration System Manufactured by Maniks"— Presentation transcript:

1 Manufactured by Maniks http://www.maniks.com/stop-check-valves.html

2  Introduction:  Maniks Stop Check Valve Design  Maniks Stop Valve introduction  Theory  Actual Use of Stop Check Valve  Stop Check Valve Design  Connections And Packing glands  Damping Chamber and etc.  Features of Maniks stop Check Valve http://www.maniks.com/stop-check-valves.html

3  Maniks Stop Check Valve:

4  Maniks Stop Check Valve Introduction:  Stop check valve plays a vital role in many industries to protect boilers and related equipments. These valves are designed with the aim to regulate the flow and to prevent backflow. This kind of valves performs two different tasks in one. Maniks manufactures stop check valve since last thirty years. Stop check valve http://www.maniks.com/stop-check-valves.html

5 Theory:  These valves are an altered rendition of the standard globe stop valve, which has the valve stem forever joined to the globe plate. In the stop check arrangement, the stem head skims in the globe circle. At the end of the day, they are by and large utilized as a globe valve to begin or stop the stream of the media, yet they additionally go about as a check valve to consequently close should weight be lost, in this manner averting reverse that could make harm hardware, for example, boilers or pumps.  The inside circle, which isn't connected to the stem, executes as a lift check enabling it to unreservedly climb and down when the stem is raised to alter the opening and shutting. If necessary, the stem can be physically brought for stream down to be halted or totally stopped. http://www.maniks.com/stop-check-valves.html

6  Actual USE OF STOP CHECK VALVES:  These stop check valve are for the most part utilized as a part of energy plants, in applications, for example, heater course, steam age and kettle encourage water, turbine cooling, and starter water and wellbeing frameworks. They likewise are utilized as a part of different applications where channeling fashioners need to consolidate the properties of a globe and check valve. Such applications may incorporate high- temperature benefit, warm recuperation steam, high-weight security benefit, geothermal administration, utilities, oil generation and refining, wellbeing frameworks, shutdown cooling, and hydro­carbon preparing.  http://www.maniks.com/stop-check-valves.html http://www.maniks.com/stop-check-valves.html

7  Stop Check Valve Design: Connections:  Butt-weld DIN (EN 10220) - ME 15 - 125 (½ - 5 in.)  Butt-weld ANSI (B 36.10 Schedule 80), - ME 15 - 40 (½ - 1½ in.)  Butt-weld ANSI (B 36.10 Schedule 40), - ME 50 - 125 (2 - 5 in.)  Socket-weld ANSI (B 16.11),- ME 50 (2 in.)  Packing gland (MSCA-X):  The "full temperature range" packing gland is the standard for the entire MSVL platform.  This ensures perfect tightness throughout the whole temperature range: –60/+150°C (–76/+302°F). http://www.maniks.com/stop-check-valves.html

8  Damping chamber: The chamber is filled with refrigerants (gas or liquid), which provides a damping effect when the valve opens and closes.  Housing: The housing is made from special, cold resistant steel. http://www.maniks.com/ http://www.maniks.com/stop-check-valves.html

9  Valve Cone: Valve cone with built in metallic stop - prevents damage to teflon ring in case of over tightening.  Spindle (MSCA-X): Made of polished stainless steel, which is ideal for O- ring sealing. http://www.maniks.com/stop-check-valves.html

10  Features of Maniks Stop Check Valve:  Applicable to HCFC, HFC, R717 (Ammonia) and R744 (CO2).  Can be used in chemical and petro-chemical applications.  Modular Concept : ◦ Each check valves housing are available with several different connection types and sizes. ◦ Possible to convert Stop check valve (MSCA) or check valve (MCHV) to any other product in MSVL family like regulating valve, stop valve or strainer. Just by replacing the complete top part.stop valve  Fast and easy valve overhaul service. It is easy to replace the top part and no welding is needed.  Designed to open at a very low differential pressure of 0.04 bar (0.58 psig). http://www.maniks.com/stop-check-valves.html