Contact Persons : Mr. M. Jawahar (+91-9626748530) jawahar@swaytronics.com Mr. Hemaraj (+91-8122023344) raj@swaytronics.com Tel: +91-44-25654321 / 22 Communication Address: R&D and Manufacturing location #1, 2nd Floor, Kadapa Road, Sri Ramanujar Nagar, Lakshmipuram, Kolathur, Chennai 600 099.
2
FEATURES: Wide input range Power Factor >0.95 Efficiency >90% High Reliable Designed for Indian Line condition APPLICATION: Street Light Bay Light Flood Light High Mass DIMENSION: L ~220mm W~92mm H~42mm ELECTRICAL CHARACTERSTICS: S.No.ParameterSpecification 1Input Voltage Range160Vac to 300Vac 2Input Frequency47Hz to 63 Hz 3EfficiencyAbove 90% 4Output Voltage (VOUT 1)33Vdc 5Output Current (IOUT 1)3.1A 6Power Factor>0.9 7Operating temperature range40DegC 8Input Under voltage cut offYes (less than 160Vac) 9Input Over voltage cut offYes (above 300Vac) 10Output short circuit protectionYes (Hick up mode) 11Output over voltage protectionYes (Hick up mode) 12Over temperature protectionYes 13FuseSlow Blow type 14PCBFR4 15Surge protectionYes 16Input & OutputWires 17EnclosureOpen Frame 18Warranty1 Year Elektronika Sway Pvt Ltd., #1, Kadapa Road, Sri Ramanujar Nagar, Lakshmipuram, Kolathur, Chennai - 600 099. Tel: +91-44-25654321 / 22 www.swaytronics.com
3
FEATURES: Wide input range Power Factor >0.95 Efficiency >90% High Reliable Designed for Indian Line condition APPLICATION: Street Light Bay Light Flood Light High Mass DIMENSION: L ~145mm W~80mm H~42mm ELECTRICAL CHARACTERSTICS: S.No.ParameterSpecification 1Input Voltage Range160Vac to 300Vac 2Input Frequency47Hz to 63 Hz 3EfficiencyAbove 90% 4Output Voltage (VOUT 1)33Vdc 5Output Current (IOUT 1)2.1A 6Power Factor>0.9 7Operating temperature range40DegC 8Input Under voltage cut offYes (less than 160Vac) 9Input Over voltage cut offYes (above 300Vac) 10Output short circuit protectionYes (Hick up mode) 11Output over voltage protectionYes (Hick up mode) 12Over temperature protectionYes 13FuseSlow Blow type 14PCBFR4 15Surge protectionYes 16Input & OutputWires 17EnclosureOpen Frame 18Warranty1 Year Elektronika Sway Pvt Ltd., #1, Kadapa Road, Sri Ramanujar Nagar, Lakshmipuram, Kolathur, Chennai - 600 099. Tel: +91-44-25654321 / 22 www.swaytronics.com
4
FEATURES: Wide input range Power Factor >0.95 Efficiency >90% High Reliable Designed for Indian Line condition APPLICATION: Street Light Bay Light Flood Light High Mass DIMENSION: L ~143mm W~62mm H~45mm ELECTRICAL CHARACTERSTICS: S.No.ParameterSpecification 1Input Voltage Range160Vac to 300Vac 2Input Frequency47Hz to 63 Hz 3EfficiencyAbove 90% 4Output Voltage (VOUT 1)33Vdc 5Output Current (IOUT 1)1.5A 6Power Factor>0.9 7Operating temperature range40DegC 8Input Under voltage cut offYes (less than 160Vac) 9Input Over voltage cut offYes (above 300Vac) 10Output short circuit protectionYes (Hick up mode) 11Output over voltage protectionYes (Hick up mode) 12Over temperature protectionYes 13FuseSlow Blow type 14PCBFR4 15Surge protectionYes 16Input & OutputWires 17EnclosureOpen Frame 18Warranty1 Year Elektronika Sway Pvt Ltd., #1, Kadapa Road, Sri Ramanujar Nagar, Lakshmipuram, Kolathur, Chennai - 600 099. Tel: +91-44-25654321 / 22 www.swaytronics.com
5
FEATURES: Wide input range Power Factor >0.95 Efficiency >90% High Reliable Designed for Indian Line condition APPLICATION: Street Light Bay Light Flood Light High Mass Indoor Light ELECTRICAL CHARACTERSTICS: S.No.ParameterSpecification 1Input Voltage Range160Vac to 300Vac 2Input Frequency47Hz to 63 Hz 3EfficiencyAbove 90% 4Output Voltage (VOUT 1)33Vdc 5Output Current (IOUT 1)1.05A 6Power Factor>0.9 7Operating temperature range40DegC 8Input Under voltage cut offYes (less than 160Vac) 9Input Over voltage cut offYes (above 300Vac) 10Output short circuit protectionYes (Hick up mode) 11Output over voltage protectionYes (Hick up mode) 12Over temperature protectionYes 13FuseSlow Blow type 14PCBFR4 15Surge protectionYes 16Input & OutputWires or Connectors 17EnclosureBoth Open & Closed Frame 18Warranty1 Year Elektronika Sway Pvt Ltd., #1, Kadapa Road, Sri Ramanujar Nagar, Lakshmipuram, Kolathur, Chennai - 600 099. Tel: +91-44-25654321 / 22 www.swaytronics.com DIMENSION: L ~ 143mm W~ 68mm H~ 43mm
6
FEATURES: Wide input range Power Factor >0.95 Efficiency >90% High Reliable Designed for Indian Line condition APPLICATION: Street Light Bay Light Flood Light Down Light Indoor Light DIMENSION: L ~ 94mm W~ 47mm H ~ 33mm ELECTRICAL CHARACTERSTICS: S.No.ParameterSpecification 1Input Voltage Range160Vac to 300Vac 2Input Frequency47Hz to 63 Hz 3EfficiencyAbove 90% 4Output Voltage (VOUT 1)33Vdc 5Output Current (IOUT 1)700mA 6Power Factor>0.9 7Operating temperature range40DegC 8Input Under voltage cut offYes (less than 160Vac) 9Input Over voltage cut offYes (above 300Vac) 10Output short circuit protectionYes (Hick up mode) 11Output over voltage protectionYes (Hick up mode) 12Over temperature protectionYes 13FuseSlow Blow type 14PCBFR4 15Surge protectionYes 16Input & OutputWires or Connectors 17EnclosureBoth Open & Closed Frame 18Warranty1 Year Elektronika Sway Pvt Ltd., #1, Kadapa Road, Sri Ramanujar Nagar, Lakshmipuram, Kolathur, Chennai - 600 099. Tel: +91-44-25654321 / 22 www.swaytronics.com DIMENSION: L ~ 100mm W ~ 53mm H ~ 37mm
7
FEATURES: Wide input range Power Factor >0.95 Efficiency >90% High Reliable Designed for Indian Line condition APPLICATION: Street Light Bay Light Flood Light Indoor Light Show Light ELECTRICAL CHARACTERSTICS: S.No.ParameterSpecification 1Input Voltage Range160Vac to 300Vac 2Input Frequency47Hz to 63 Hz 3EfficiencyAbove 90% 4Output Voltage (VOUT 1)33Vdc 5Output Current (IOUT 1)350mA 6Power Factor>0.9 7Operating temperature range40DegC 8Input Under voltage cut offYes (less than 160Vac) 9Input Over voltage cut offYes (above 300Vac) 10Output short circuit protectionYes (Hick up mode) 11Output over voltage protectionYes (Hick up mode) 12Over temperature protectionYes 13PCBFR4 14Surge protectionYes 15Input & OutputWires or Connectors 16EnclosureBoth Open & Closed Frame 17Warranty1 Year Elektronika Sway Pvt Ltd., #1, Kadapa Road, Sri Ramanujar Nagar, Lakshmipuram, Kolathur, Chennai - 600 099. Tel: +91-44-25654321 / 22 www.swaytronics.com DIMENSION: L ~78mm W~45mm H~32mm
8
FEATURES: Wide input range Power Factor >0.95 Efficiency >87% High Reliable Designed for Indian Line condition APPLICATION: Street Light Bay Light Flood Light Down Light Indoor Light DIMENSION: L ~72mm W~40mm H~30mm ELECTRICAL CHARACTERSTICS: S.No.ParameterSpecification 1 Input Voltage Range160Vac to 300Vac 2 Input Frequency47Hz to 63 Hz 3 EfficiencyAbove 87% 4 Output Voltage (VOUT 1)7Vdc 5 Output Current (IOUT 1)770mA 6 Power Factor>0.9 7 Operating temperature range40DegC 8 Input Under voltage cut offYes (less than 160Vac) 9 Input Over voltage cut offYes (above 300Vac) 10 Output short circuit protectionYes (Hick up mode) 11 Output over voltage protectionYes (Hick up mode) 12 Over temperature protectionYes 13 PCBFR4 14 Surge protectionYes 15 Input & OutputWires or Connectors 16 EnclosureBoth Open & Closed Frame 17 Warranty1 Year Elektronika Sway Pvt Ltd., #1, Kadapa Road, Sri Ramanujar Nagar, Lakshmipuram, Kolathur, Chennai - 600 099. Tel: +91-44-25654321 / 22 www.swaytronics.com DIMENSION: L ~78mm W~45mm H~32mm
9
FEATURES: Wide input range Efficiency >80% High Reliable Designed for Indian Line condition APPLICATION: Flood Light Show Light Down Light ELECTRICAL CHARACTERSTICS: S.No.ParameterSpecification 1Input Voltage Range160Vac to 300Vac 2Input Frequency47Hz to 63 Hz 3EfficiencyAbove 80% 4Output Voltage (VOUT 1)3.5Vdc(1W) & 10Vdc(3W) 5Output Current (IOUT 1)350mA 6Operating temperature range40DegC 7Surge protectionYes 8Input & OutputWires 9EnclosureBoth Open & Closed Frame 10Warranty1 Year Elektronika Sway Pvt Ltd., #1, Kadapa Road, Sri Ramanujar Nagar, Lakshmipuram, Kolathur, Chennai - 600 099. Tel: +91-44-25654321 / 22 www.swaytronics.com DIMENSION: L ~ 39 mm W~ 29 mm H ~ 23 mm