1 THE DESIGN CRITERIA FOR WASTEWATER SYSTEMS (30 TAC Chapter 217)
Title Page THE DESIGN CRITERIA FOR WASTEWATER SYSTEMS (30 TAC Chapter 217) Water Quality/Stormwater Seminar October 12, 2016 Water Quality/Stormwater Seminar October 12, 2016

2 Presented By: Louis C. Herrin, III, P.E.
Engineer, Water Quality Division Louis C. Herrin, III, P.E. Engineer, Water Quality Division A picture of Louis Herrin

3 chapter 217 Subchapter A Subchapter B Subchapter C Subchapter D
Administrative Requirements Subchapter A Treatment Facility Design Requirements Subchapter B Conventional Collection Systems Subchapter C Alternative Collection Systems Subchapter D Preliminary Treatment Units Subchapter E Activated Sludge Systems Subchapter F Fixed Film and Filtration Units Subchapter G Natural Treatment Facilities Subchapter H Sludge Treatment Units Subchapter J Chemical Disinfection Subchapter K UV Light Disinfection Subchapter L Safety Subchapter M Chapter 217 Subchapter A Administrative Requirements Subchapter B Treatment Facility Design Requirements Subchapter C Conventional Collection Systems Subchapter D Alternative Collection Systems Subchapter E Preliminary Treatment Units Subchapter F Activated Sludge Systems Subchapter G Fixed Film and Filtration Units Subchapter H Natural Treatment Facilities Subchapter J Sludge Treatment Units Subchapter K Chemical Disinfection Subchapter L UV Light Disinfection Subchapter M Safety

4 chapter 217 Check the status of your summary transmittal letter.
Check the status of your summary transmittal letter. A picture is the web page box that you can check the status of your project.

5 History of Wastewater Treatment Design Criteria in Texas
The first consolidated design criteria was adopted by Texas State Department of Health on 9/18/1950. This document was revised on 9/11/1961, 9/18/1968, 9/13/1970, 9/1/1974, 6/1/1981, 4/20/1990, 8/28/2008, 12/4/2015 The first consolidated design criteria was adopted by Texas State Department of Health on 9/18/1950. This document was revised on 9/11/1961, 9/18/1968, 9/13/1970, 9/1/1974, 6/1/1981, 4/20/1990, 8/28/2008, and 12/4/2015 A picture of cover of the 9/18/1968 design criteria booket

6 Subchapter - A Administrative requirements

7 PURPOSE AND APPLICABILITY
Section (Applicability) The grandfathering clause: The existing wastewater treatment system is subject to the design requirements at the time of approval Section (Applicability) the grandfathering clause The existing wastewater treatment system is subject to the design requirements at the time of approval

8 Re-adoption of the Chapter 317

9 SOME IMPORTANT DEFINITIONS
MAINTENANCE REHABILITATE ALTER or ALTERATION GRAVITY RELIEF SEWER DESIGN FLOW GRINDER PUMP EQUALIZATION BASIN INNOVATIVE TECHNOLOGIES MAINTENANCE REHABILITATE SURCHARGE GRAVITY RELIEF SEWER DESIGN FLOW GRINDER PUMP EQUALIZATION BASIN ALTER

10 APPLICABILITY EXAMPLES FOR ALTER
Replaced a gravity thickener with a belt press and plan to use thickener as a digester instead. Replace a treatment unit or a collection system unit. Modify in a way that changes: capacity; function; process; mode of operation; configuration; a design parameter; a major design assumption

11 APPLICABILITY EXAMPLES REHABILITATION
Repair of a collection system using a lining or coating method. Trenchless technologies: Cement mortar lining Epoxy spray lining Cure in place piping Slip lining  Other trenchless method of installing, replacing, or repairing   Rehabilitate a portion of a 50-year old collection system by cleaning, televising and spraying an epoxy lining inside the pipe. Repair of a collection system using a lining or coating method. Trenchless technologies: Cement mortar lining Epoxy spray lining Cure in place piping Slip lining  Other trenchless method of installing, replacing, or repairing Rehabilitate a portion of a 50-year old collection system by cleaning, televising and spraying an epoxy lining inside the pipe. Rehabilitate a portion of a 50-year old collection system by cleaning, televising and spraying an epoxy lining inside the pipe These are subject to review under the proposed 30 TAC 217 criteria

12 APPLICABILITY EXAMPLES RE-RATE
Change the design flow or design organic loading of a treatment unit, without altering the unit, based on actual performance data.   An existing WWTP has a new permit with stricter effluent limitations. Without increasing the flow capacity the plant is going to demolish its activated sludge process and construct a membrane process in its place. This is subject to the 30 TAC 217.

13 APPLICABILITY EXAMPLES MAINTENANCE
Replacement must not cause alteration. Scheduled preventative care, repair, or the equivalent replacement of components or appurtenances of a treatment unit or a collection system unit. Maintenance does not include replacement of a treatment unit or a collection system unit. Replacement must not cause alteration. Scheduled preventative care, repair, or the equivalent replacement of components or appurtenances of a treatment unit or a collection system unit. Maintenance does not include replacement of a treatment unit or a collection system unit. WWTP replaces the motor on a pump with the same gallons per minute and head rating. Replacing the squeegee blades on a mechanical clarifier. These are NOT subject to 30 TAC Chapter 217. WWTP replaces the motor on a pump with the same gallons per minute and head rating. Replacing the squeegee blades on a mechanical clarifier. These are NOT subject to 30 TAC Chapter 217.

14 SUBCHAPTER - B TREATMENT FACILITY DESIGN REQUIREMENTS

15 Organic Loadings and Flows : TABLE B.1.
Source Remarks Daily Wastewater Flow (gallons/person) Wastewater Strength (mg/l BOD5) Wastewater Strength (mg/l NH3-N) Municipality Residential 75-100 15-75 Subdivision Trailer Park (Transient) 2½ Individuals per Trailer 50-60 Mobile Home Park 3 Individuals per Trailer 50-75 300 School Cafeteria & Showers Cafeteria/No Showers 20 15 Recreational Parks Overnight User Day User 30 5 Office Building or Factory A facility must be designed for the largest shift 20 Hotel/Motel Per Bed Restaurant Per Meal 7-10 1000* Restaurant with bar or cocktail lounge 9-12 Hospital 200 Nursing Home Alternative Collection Systems (Subchapter D) Per Capita 75 N/A *Based on a restaurant with a grease trap Picture of table from the rules showing that NH3-N was added to the existing tables with a range from 15 to 75 mg/l for municipality.

16 Some things to remember
The differences between the permitted flow from max 30 day average and annual average The minimum information needed to rerate a wastewater treatment plant Emergency power requirements in and (Clarity & Consistency) Flow measurement weirs for small plants The differences between the permitted flow from max 30 day average and annual average The minimum information needed to rerate a wastewater treatment plant Emergency power requirements in and (Clarity & Consistency) Flow measurement weirs for small plants

17 Some things to remember
One hundred-year flood plain requirements Buffer Zones and Odor Abatement Power reliability to be determined using records from past 60 consecutive months instead of past 24. One hundred-year flood plain requirements Buffer Zones and Odor Abatement Power reliability to be determined using records from past 60 consecutive months instead of past 24.

18 SUBCHAPTER - C CONVENTIONAL COLLECTION SYSTEMS

19 Pipe Design Bending of gravity and force main pipes is prohibited.
Requirement for gaskets operate properly at atmospheric pressure Equation (k)(4) to refer to the structural calculation in equation (k)(2) Bending of gravity and force main pipes is prohibited Requirement for gaskets operate properly at atmospheric pressure Equation (k)(4) to refer to the structural calculation in equation (k)(2)

20 In Cases when Collection system cannot be located at least nine feet away from water supply line
A picture of a table from the design criteria showing what rules apply to water line separation from wastewater lines.

21 Minimum and Maximum Pipe Slopes: Table C.2
IA picture of a table from the design criteria showing the minimum and maximum pipe slopes

22 Trench Cross Section Showing Terminology
A picture of a from the design criteria showing a typical trench cross section with the terminology.

23 Maximum Manhole Spacing: Table C3
Requirement for engineer to specify an appropriate national reference standard for sealing manhole covers Clarify locations where bolted and gasketed manholes are required Maximum Manhole Spacing: Table C3 Requirement for engineer to specify an appropriate national reference standard for sealing manhole covers Clarify locations where bolted and gasketed manholes are required Maximum Manhole Spacing: Table C3 A picture of a table from the design criteria showing manhole spacing by the pipe diameter

24 TESTING REQUIREMENTS FOR MANHOLES
Correct units in (b)(2)(d), related to tightening external clamps on the vacuum testing cover Allow ASTM testing requirements for manholes Correct units in (b)(2)(d), related to tightening external clamps on the vacuum testing cover Allow ASTM testing requirements for manholes A picture showing a test form

25 Lift stations Some Requirements Hoisting equipment and access
Separate pipes for sump pumps Expected peak flow and firm pumping capacity Picture of a lift station

26 Lift stations Some Other Requirements:
Add backup high water float requirement for wet well level detection Control pad must be large enough for personnel to do electrical work safely Ladders and access hatches must also meet OSHA Non-corrosive vents for all lift stations Explosion-proof equipment for all lift stations Some other Requirements: Add backup high water float requirement for wet well level detection Clarifications Control pad must be large enough for personnel to do electrical work safely Ladders and access hatches must also meet OSHA Non-corrosive vents for all lift stations Explosion-proof equipment for all lift stations

27 EMERGENCY PROVISIONS FOR LIFT STATIONS
Clarify that generators or auxiliary pumps may be used Add minimum fuel tank size requirements based on hours of fuel Use of collection system or spill containment as a sole system for preventing discharge to be prohibited Clarify quick connection design and generator electric loading design Clarify that generators or auxiliary pumps may be used Add minimum fuel tank size requirements based on hours of fuel Use of collection system or spill containment as a sole system for preventing discharge to be prohibited Clarify quick connection design and generator electric loading design

28 FORCE MAINS Fatigue life calculation requirements
Consider basing minimum velocities on the smallest pump operating at full speed Consider additional flushing requirement for variable speed pumps that normally operate below minimum velocities Clarify that air release valves must be non-corrosive Add fatigue life calculation requirements Consider basing minimum velocities on the smallest pump operating at full speed Consider additional flushing requirement for variable speed pumps that normally operate below minimum velocities Clarify that air release valves must be noncorrosive

29 Materials for Force Main Pipes Identification of Force Main Pipes
FORCE MAINS Materials for Force Main Pipes Force Main Pipe Joints Identification of Force Main Pipes Force Main Design Force Main Testing Materials for Force Main Pipes Force main pipe joints Identification of the Force Main Pipes Force Main Design Force Main Testing

30 Some other sections SECTION - §217.69: Requirements for inspecting and maintaining wastewater collection systems and post-installation inspections of collection system rehabilitation projects SECTION - §217.70: Collection system for Reclaimed Water Facilities SECTION - §217.69: Requirements for inspecting and maintaining wastewater collection systems and post-installation inspections of collection system rehabilitation projects SECTION - §217.70: Collection system for Reclaimed Water Facilities

31 SUBCHAPTER - E PRELIMINARY TREATMENT UNITS

32 Some Important Sections
General Preliminary Treatment Requirements Grinding devices vs screening devices Coarse Screens and Fine Screens Grit Removal Systems, Grit Chambers and Grit Handling General Preliminary Treatment Requirements Grinding devices vs screening devices Coarse Screens and Fine Screens Grit Removal Systems, Grit Chambers and Grit Handling Two pictures of bar screens

33 Some Important Sections
Requirements for flow Equalization Basins Primary Clarifiers Requirements for flow Equalization Basins Primary Clarifiers A picture of a clarifier

34 SUBCHAPTER - F ACTIVATED SLUDGE SYSTEMS

35 Activated Sludge Systems
Requirements for an Aeration Basin Requirements for Clarifiers. Requirements for Both Aeration Basins and Clarifiers. Aeration Basin and Clarifier Sizing--Traditional Design. Aeration Equipment Sizing. Requirements for an Aeration Basin Requirements for Clarifiers. Requirements for Both Aeration Basins and Clarifiers. Aeration Basin and Clarifier Sizing--Traditional Design. Aeration Equipment Sizing. A picture of a cross-section of a clarifier

36 SUBCHAPTER - G FIXED FILM AND FILTRATION UNITS

37 NEW TECHNOLOGY Add requirements for cloth media filters
a picture of a cloth filter

38 SUBCHAPTER - H NATURAL TREATMENT FACILITIES

39 Natural Systems Considerable rewording done to § Design Criteria for Natural Treatment Facilities Corrected aerated pond treatment efficiency equation Considerable rewording done to § Design Criteria for Natural Treatment Facilities Corrected aerated pond treatment efficiency equation A picture of liner of a pond

40 SUBCHAPTER - K CHEMICAL DISINFECTION

41 Chlorination/Dechlorination Systems
Clarify intent related to tank placement for spill containment Allow a minimum length to width ratio as an alternate to modeling for chlorine mixing Clarify intent related to tank placement for spill containment Allow a minimum length to width ratio as an alternate to modeling for chlorine mixing A picture of several 150 pound chlorine tanks.

42 SUBCHAPTER - M SAFETY

43 SAFETY AND SECURITY AUDITS
Require the owner to conduct annual audits and to prepare and implement a corrective action plan. Require the owner to conduct annual audits and to prepare and implement a corrective action plan.

44 QUESTIONS? A background picture of a Question Mark?