Presentation is loading. Please wait.

Presentation is loading. Please wait.

Effect of the Solenoid Field on the Luminosity Monitor

Similar presentations


Presentation on theme: "Effect of the Solenoid Field on the Luminosity Monitor"— Presentation transcript:

1 Effect of the Solenoid Field on the Luminosity Monitor
The XXX PANDA meeting Sep.7-11,2009, Juelich Effect of the Solenoid Field on the Luminosity Monitor Huagen Xu IKP: T. Randriamalala, J. Ritman and T. Stockmanns 15 September, September, 2018

2 Outline One Tentative Geometry of LuMo
Effect of the Solenoid Field on LuMo Confirmed Results Summary 2

3 1. One Tentative Geometry
16 Silicon sensors with trapezoidal shape on 4 planes; Distance between neighbouring planes: 20cm. Dimension: 2 cm(short side)X5 cm(height)X5.33 cm(long side); Thickness : 150 μm; Single/Double side stripped; 3

4 Digi & Reco Reco Hits Plot Strip on Front/Back Side, pitch = 50 μm
FrontSide BackSide 4 Reco Hits Plot

5 Spatial Resolution σ = 10 μm/30 μm 52.7 μm σ = 30 μm/10 μm 158.2 μm 5

6 Track Theta RecoHitsTheta : Theta by fitting RecoHits ,
Beam axis θ Hits RecoHitsTheta : Theta by fitting RecoHits , MCHitsTheta : Theta by fitting MCHits, MCtrue Theta : Theta of particle’s mother track 6

7 RecoHitsTheta - MCTruetheta MCHitsTheta - MCTruetheta
Theta resolution RecoHitsTheta - MCTruetheta MCHitsTheta - MCTruetheta 7

8 2. Effect of the Solenoid Field
Field on Field off RecoHitsTheta Resolution vs Beam Momentum for antiproton Difference 8

9 Peak of MCHits Theta RMS of MCHits Theta Field On Field Off On - Off
9 Field On Field Off On - Off

10 Field Map plotted one map file map file1+2+3+4
10

11 MCHits’ plot with field and with no field
Field On Field Off MCHits’ plot with field and with no field BoxGenerator; Beam Particle: antiProton; Beam momentum: 1.5GeV/c; Fixed theta: 5mrad; Azimuth: 0~360; Give rise to ~0.5 mrad shift toward beam axis for antiProton. 11

12 3. Confirmed Information
Reason: due to the rectangular aperture of downstream door for solenoid, the Y-field is much higher than X-field. Figure from Jost Lühning 12

13 Track of Proton from IP Emitted from IP with 1.5GeV/c and 5mrad
Figure from Jost Lühning 13

14 Track of Proton and antiProton from IP
Emitted from IP with 1.5GeV/c and 5mrad Proton: red antiProton: blue Figure from Jost Lühning 14

15 Geane prediction (forward mode)
Start plane: IP plane; Start position: IP position(0,0,0); (antiProton with 1.5GeV/c and 5mrad) 15

16 (Geane – MC)/ (Geane Propagation Error)
Pull distribution (Geane – MC)/ (Geane Propagation Error) 16 Geane Hits fit theta MCHits theta

17 Geane prediction (Backward)
Start plane: the first detector plane; Start position: the MC Hits of antiProton on the first detector plane;

18 Position and Theta (Backward)
fX, fY at IP Theta = 5.022mrad

19 4. Summary With a new tentative geometry of LuMo the effect of the Solenoid field was found, for antiProton with momentum of 1.5GeV/c the theta of track would be shifted ≈ LuMo ; The effect was confirmed by Solenoid experts; The effect was convinced by using Geane packages with forward and backward mode as well. 19

20 Thanks for your attention!
20


Download ppt "Effect of the Solenoid Field on the Luminosity Monitor"

Similar presentations


Ads by Google