Download presentation
Presentation is loading. Please wait.
1
Magnetostrictive Liquid Level Transmitter
Industrial Automation/Bu Measurement and analytics, February 2017 The New LMT Series Magnetostrictive Liquid Level Transmitter
2
Introducing the LMT Series
Next Generation Magnetostrictive Transmitter Why LMT Series? The LMT’s principle of operation and simple setup ensure customer process is always measured reliably and accurately. This allows them to maximize their process efficiency, uptime and profits. LMT is available as an insertion style “wetted” transmitter (LMT100) or as an externally mounted, non-intrusive design (LMT200) for use with the market leading KM26 magnetic level gauge or with any other float and level chamber. September 16, 2018September 16, 2018
3
Introducing the LMT Series
Next Generation Magnetostrictive Transmitter Industries Served Oil and Gas Petrochemical Chemical Power Generation Water & wastewater Pulp and Paper Biotech Marine September 16, 2018September 16, 2018
4
Introducing the LMT Series
Next Generation Magnetostrictive Transmitter Application Examples Chemical Storage Level Boiler Control Feedwater Heater Control Hydrocarbon Storage Level Separator Level Sump Level Interface Level Distillation Column Casing Mud Level Mining Floatation Cell Level Purified Water Level Acid Storage Tank Level Application experience in over 100,000 applications worldwide LMT Series: Intrusive or nonintrusive level measurement September 16, 2018September 16, 2018
5
Introducing the LMT Series
Superior features, simpler to use, Safe & Reliable Feature Safety Ease of Use Flexibility Reliability Onboard Waveform Display & Diagnostics ü Easy Setup Menu Dual Compartment with secondary Sealed Electronics Floats do not require batteries Reliable interface measurement DTM & EDDs for Remote viewing and calibration Built-in RTD Option – LMT100 wetted sensor Mounting orientation can be changed in field High Temperature & Cryogenic Capabilities Non-Intrusive - Externally Mounted LMT200 Insertion Well for removal even when process is in vessel HART 7 Communication ATEX/IECEx, FM US & C Approvals September 16, 2018September 16, 2018
6
Introducing the LMT Series
Superior Performance Accuracy 0.01% of Full Scale or 0.05”,whichever is greater Repeatability 0.005% of Full Scale or 0.015”, whichever is greater Update Rate Up to 10 Updates per Second Reliability Measurement Signal Quality is Unaffected by Process Conditions September 16, 2018September 16, 2018
7
Introducing the LMT Series
Next Generation Magnetostrictive Transmitter Magnetostrictive Transmitters : LMT100 and LMT200 Output: 4-20mA HART 7 Approvals: ATEX, IECEx, FM US & Canadian, CRN Material options including: 316L, Hast C, Alloy 20, PVDF etc. Superior Sensor (Patent #5,473,245) Local indication with HMI display Dual compartment housing with separate field terminal compartment Loop powered to 22m (75ft) probe length Total and/or interface level measurement Pressure to bar (2400 psig) Std bar (1800 psig) Temperature range: to 426.6ºC (-320 to 800ºF) Field replaceable/upgradable electronics module Built-in RFI/EMI filter September 16, 2018September 16, 2018
8
Introducing the LMT Series
LMT100 Mounting & Options LMT100: Accurate Level and Interface Measurement LMT Series: Rotatable Housing Easy Setup: Fast Startup September 16, 2018September 16, 2018
9
Introducing the LMT Series
LMT200 Mounting & Options LMT200 Bottom Mounting LMT200 Valve Position Transmitter LMT200 with 90º Bend for Cryogenic applications September 16, 2018September 16, 2018
10
Introducing the LMT Series
Configuration Integrated HMI EDD in Handheld terminal DTM in Control Systems First magnetostrictive transmitter with TTG (Through The Glass) technology. - Graphic display with four key operation - Configuration in hazardous areas without powering off the transmitter Easy to use in field HART 7 communication with HHT 475 AMS 13.0 PDM 8.2 Efficient intelligent device management - Open, standardized interface Support full device functionality Seamless communication with various host control systems September 16, 2018September 16, 2018
11
Introducing the LMT Series
Diagnostics functions for best asset management LMT Diagnostics per NE 107 include: Sensor Level Sensor Failure Sensor Board Fault Sensor Communication Failure Temperature sensor failure Electronics Electronics Memory Failure Electronics Insufficient Input Voltage Operating conditions and process Level Sensor Out of Limits Temperature Sensor Out of Limits Installation and start up Data Simulation Warning Sensor Configuration Warning Maintenance required Out of specification Check function Failure September 16, 2018September 16, 2018
12
Introducing the LMT Series
World Leader in Magnetostrictive Level Technology Summary Magnetostrictive technology is one of the most accurate liquid level transmitter technologies in the world today One Design Fits All - Mounting configuration can be changed in the field…by the user! Engineered Solutions with Minimal Process Variable Influence Multiple probe designs available to meet a wide array of applications Factory Calibrated. Set It and Forget It. Never Needs Recalibration The LMT Series now makes Level Measurement: Easier, More Reliable, Safer & More convenient The new LMT Series- “ Level Measurement made easy” September 16, 2018September 16, 2018