Presentation is loading. Please wait.

Presentation is loading. Please wait.

High Sensitivity Luminescence Detection

Similar presentations


Presentation on theme: "High Sensitivity Luminescence Detection"— Presentation transcript:

1 High Sensitivity Luminescence Detection
LuminMax-C for High Sensitivity Luminescence Detection Look for potential opportunity for strategic alliance, VC, or initial funding Maxwell Sensors Inc. 9/16/2018 Maxwell Sensors Inc.

2 Who will use ? Biotechnology research laboratories
University biological and biochemical laboratories Hospital research laboratories Government biological and biomedical laboratories Food industry Environmental testing Forensic testing 9/16/2018 Maxwell Sensors Inc.

3 What kind of tests ? Immunoassay and proteomics
Nucleic acids, DNA, RNA, and genomics Cell viability tests, luciferase, ATP assay Clinical diagnostics and tests E-coli bacterial food tests Toxin environmental tests Restaurant sanitary tests 9/16/2018 Maxwell Sensors Inc.

4 What is Luminescence ? - It generates light by chemical reactions, the light signal can be used for analyte quantification - It does not require external light source to excite the analyte, such as fluorescence or absorbance measurement - Due to photon counting detector can detect a few photons, the detection can be extremely sensitive - Common luminescence are chemiluminescence & bioluminescence 9/16/2018 Maxwell Sensors Inc.

5 How the light is generated?
- There are more than 50 chemical reactions have been used to generate light - The most common reactions use: Substrate + Enzyme  excited state molecule*  Light or Substrate + Enzyme + ATP  excited state molecule*  Light *excited state molecule: e.g. dioxetane When the 6M patients show up in the E-room, one of---, to quickly decide should let the patient go home, or admit for surgery or other checkup 9/16/2018 Maxwell Sensors Inc.

6 What are the substrates?
There are many different substrates & their derivatives, such as Troponin is an established and standard markers, but it require sensitivity – No system meet these requirements 9/16/2018 Maxwell Sensors Inc.

7 What are the substrates?
There are many different substrates & their derivatives, such as Luciferin Acridinium ester Luminol Isoluminol Lumi-PPD,Lumigen-PS-atto, etc Troponin is an established and standard markers, but it require sensitivity – No system meet these requirements 9/16/2018 Maxwell Sensors Inc.

8 What are the Enzymes? Horseradish peroxidase (HRP) Luciferase
Alkaline phosphatase (AP) Peroxidase Dehydrogenase Galactosidase, etc. Troponin is an established and standard markers, but it require sensitivity – No system meet these requirements 9/16/2018 Maxwell Sensors Inc.

9 Example 1 Enzyme can be used for quantification
Troponin is an established and standard markers, but it require sensitivity – No system meet these requirements Enzyme can be used for quantification 9/16/2018 Maxwell Sensors Inc.

10 Example 2 Enzyme, ATP, or Mg++ (Ca++) can be used for quantification
Troponin is an established and standard markers, but it require sensitivity – No system meet these requirements 9/16/2018 Maxwell Sensors Inc.

11 How to use for quantification?
Enzyme: can be used for indirect labeling proteins or nucleic acids, so it can be used to quantify proteins or nucleic acids Luciferase, ATP, or Ca++ can be used for direct quantification of biological cells Troponin is an established and standard markers, but it require sensitivity – No system meet these requirements 9/16/2018 Maxwell Sensors Inc.

12 How to label proteins? *: enzyme Light
Troponin is an established and standard markers, but it require sensitivity – No system meet these requirements Light 9/16/2018 Maxwell Sensors Inc.

13 Enzyme linked immunosorbent assay
(ELISA) 9/16/2018 Maxwell Sensors Inc.

14 Sandwich & Competitive assay
9/16/2018 Maxwell Sensors Inc.

15 How to label nucleic acids?
Troponin is an established and standard markers, but it require sensitivity – No system meet these requirements 9/16/2018 Maxwell Sensors Inc.

16 How to label nucleic acids?
Troponin is an established and standard markers, but it require sensitivity – No system meet these requirements 9/16/2018 Maxwell Sensors Inc.

17 Glow Luminescence Troponin is an established and standard markers, but it require sensitivity – No system meet these requirements 9/16/2018 Maxwell Sensors Inc.

18 Flash Luminescence Stable Flash (Promega, Lumigen, etc.)
Troponin is an established and standard markers, but it require sensitivity – No system meet these requirements Conventional flash 9/16/2018 Maxwell Sensors Inc.

19 Luminescence Response Time
Lumigen-PS-atto (rapid response) 9/16/2018 Maxwell Sensors Inc.

20 Sensitivity for Cell Analysis
Promega kit 9/16/2018 Maxwell Sensors Inc.

21 LuminMax-C vs. Beckman-LD400
9/16/2018 Maxwell Sensors Inc.

22 LuminMax-C System 9/16/2018 Maxwell Sensors Inc.

23 Luminescent Kits Resources
Promega- reagent kits, cell kits Stratagene- reagent kits Bioassay System- luciferase gene assay kits Pierce- enzymes, substrate KPL- enzymes, substrates Lumigen- substrates etc. 9/16/2018 Maxwell Sensors Inc.

24 Microplate Resources Nunc Costar, Corning, Perkin Elmer,
BD Biosciences, Greeiner bio-one Evergreen Sciences Maxwell Sensors Inc. (low cost strip & reusable tray) 9/16/2018 Maxwell Sensors Inc.

25 Microplate Varieties Types of microplates
Bottom clear: read from bottom (for MSI-LuminMax-C) Total opaque: need to read from top, signal depends on solution volume Types of surface treatment: Untreated, Sterile Treated, Sterile – increase binding Coating for specific proteins or Nucleic acids 9/16/2018 Maxwell Sensors Inc.

26 LuminMax-C Advantages
User Friendly: Very easy to use, minutes learning will be able to start to operate. Cost Effective: The most cost-effective and high performance system on the world market. Offers low cost consumables High Sensitivity: One of the most sensitive photoncounting luminometer on the market, the system has the ability to detect a few photons or attomoles molecules. 9/16/2018 Maxwell Sensors Inc.

27 LuminMax-C Advantages (conti.)
Extremely Compact: It is suitable for laboratory uses. Consistent Testing Results: Signal is sample volume independent. Minimum Cross-talk: Unique adapter design offers minimal cross-talk and excellent optical efficiency. Solid Packaged: The system is packaged in metal case; it prevents components damage or mis-alignment during shipping. Excellent service: Rapid responses (e.g. 24 hours) and immediately actions 9/16/2018 Maxwell Sensors Inc.


Download ppt "High Sensitivity Luminescence Detection"

Similar presentations


Ads by Google