Download presentation
Presentation is loading. Please wait.
1
2202 Lakeside Boulevard Edgewood, MD 21040 410-510-9100
APD USER TRAINING 2202 Lakeside Boulevard Edgewood, MD Version 2.3 April 2005
2
Important Information
The APD 2000® does not require calibration but Smiths Detection recommends yearly preventive maintenance Smiths Detection is confident that a comprehensive preventive maintenance program and monthly functional checks will ensure full operational readiness of the APD 2000® For service inquiries please call or 9/17/2018 ©COPYRIGHT Smiths Detection Inc
3
Important Information (Continued)
For optimal performance, the APD 2000® should be powered up at least once a month The confidence test should be performed every time the APD 2000® is powered up 9/17/2018 ©COPYRIGHT Smiths Detection Inc
4
Introduction to the APD 2000
Portable hand-held chemical agent monitor and detector Designed for emergency first response to hazardous chemical spills and terrorist attacks 9/17/2018 ©COPYRIGHT Smiths Detection Inc
5
©COPYRIGHT Smiths Detection Inc. 1998-2005
APD Features Detects chemical warfare agents and civilian threats such as pepper spray and mace Provides actual identity and relative concentration of agent under most environmental conditions Features superior interferent rejection The latest models include integrated gamma radiation dosimeter 9/17/2018 ©COPYRIGHT Smiths Detection Inc
6
APD 2000 Features (continued)
Selectable operating modes (monitor or detect) Lightweight, ergonomic design Easy to read visual display and audible alarm Powered by six high quality alkaline C cell batteries 9/17/2018 ©COPYRIGHT Smiths Detection Inc
7
©COPYRIGHT Smiths Detection Inc. 1998-2005
APD Components APD 2000® User’s Manual & Resource CD Shoulder Strap Filtered Nozzle Standoff Pack Communications Cable Quick User’s Guide Confidence Sample Transit Case Batteries 9/17/2018 ©COPYRIGHT Smiths Detection Inc
8
©COPYRIGHT Smiths Detection Inc. 1998-2005
APD Specifications 9/17/2018 ©COPYRIGHT Smiths Detection Inc
9
©COPYRIGHT Smiths Detection Inc. 1998-2005
APD Options Integrated gamma radiation dosimeter upgrade Remote communication 9/17/2018 ©COPYRIGHT Smiths Detection Inc
10
Principles of Operation
9/17/2018 ©COPYRIGHT Smiths Detection Inc
11
Principles of Operation (Continued)
Display and audio alarm ALARM CW NERV GB + + – – To silence alarm, press SELECT key 9/17/2018 ©COPYRIGHT Smiths Detection Inc
12
Operating the APD 2000 Controls and Indicators ® 9/17/2018
©COPYRIGHT Smiths Detection Inc
13
©COPYRIGHT Smiths Detection Inc. 1998-2005
APD 2000 1 2 1 2 Nozzle 3 Nozzle Protective Cap Filtered Nozzle Standoff Auxiliary Port 4 Auxiliary Port Cap 5 Battery Compartment 6 Battery Cap 7 9/17/2018 ©COPYRIGHT Smiths Detection Inc
14
©COPYRIGHT Smiths Detection Inc. 1998-2005
Confidence Sample G simulant tests for nerve agents H simulant tests for blister agents G H 9/17/2018 ©COPYRIGHT Smiths Detection Inc
15
©COPYRIGHT Smiths Detection Inc. 1998-2005
APD Display Status Indicator Agent Mode Indicator Log Indicator READY READY CW L + R 01 NOV :30 CW L + + R 01 NOV :30 Polarity Indicator + – Backflush Indicator + – RAD Indicator Data Line 9/17/2018 ©COPYRIGHT Smiths Detection Inc
16
APD 2000 Display (Continued)
ALARM CW NERV GB During ALARM, information about the alarm event appears on the Data Line NERV GB 9/17/2018 ©COPYRIGHT Smiths Detection Inc
17
APD 2000 Display (Continued)
Use the OPTION and SELECT keys to scroll through the menus and available options LOG MODE: L READY CW SET DATE/TIME APD2000 v6.12d SERVICE: HORN MODE: COMM MODE: OPERATING MODE: DISPLAY MODE: ALARM MODE: 9/17/2018 ©COPYRIGHT Smiths Detection Inc
18
©COPYRIGHT Smiths Detection Inc. 1998-2005
APD Keypad POWER - Turns unit on/off CLEAR - Activates backflush MODE - Switches agent mode between CW, CWVX, IRRT, and TEST LIGHT - Toggles display backlight on/off EVENT - Used to assign an event number AUX - Toggles Rad capability on and off OPTION - Activates menus and cycles through options SELECT - Silences horn during alarm. When menus are activated, selects currently displayed option 9/17/2018 ©COPYRIGHT Smiths Detection Inc
19
©COPYRIGHT Smiths Detection Inc. 1998-2005
Operating the APD 2000 Precautions 9/17/2018 ©COPYRIGHT Smiths Detection Inc
20
©COPYRIGHT Smiths Detection Inc. 1998-2005
Radiation Hazard WARNING The APD 2000® contains a 10 millicurie Nickel 63 radioactive source. Do not attempt to open the APD 2000® housing. The use of this device is regulated by General License Provisions of the U.S. Nuclear Regulatory Commission, Agreement State or Licensing State. If the housing is broken or cracked, wrap the APD 2000® in a plastic bag and pack it in its original shipping container. Call Smiths Detection Inc. (Edgewood, MD) at and ask to speak to the APD 2000® program manager for further instructions. 9/17/2018 ©COPYRIGHT Smiths Detection Inc
21
Survey the Environment
WARNING Do not start up the APD 2000® in an explosive atmosphere. An arc of electricity could cause an explosion. 9/17/2018 ©COPYRIGHT Smiths Detection Inc
22
Survey the Environment (Continued)
Make sure you are in a clean environment Be aware of wind conditions Know potential interferents in your environment 9/17/2018 ©COPYRIGHT Smiths Detection Inc
23
Interferents Potential Causes of False Alarms
Cleaning compounds and disinfectants Aromatic vapors Smokes and fumes 9/17/2018 ©COPYRIGHT Smiths Detection Inc
24
Interferents (continued)
If you suspect a false alarm: Check for vapor sources Remove the source of interferent or Press the CLEAR key 9/17/2018 ©COPYRIGHT Smiths Detection Inc
25
©COPYRIGHT Smiths Detection Inc. 1998-2005
Blowing Sand or Dust Check the filtered nozzle standoff for sand or dust residue If any residue is visible, replace with a new filter 9/17/2018 ©COPYRIGHT Smiths Detection Inc
26
©COPYRIGHT Smiths Detection Inc. 1998-2005
Temperature Extremes Cold temperatures (below 40F) require a longer warm-up period Battery life Less than 3 hours at 43°F One hour or less at 32°F 9/17/2018 ©COPYRIGHT Smiths Detection Inc
27
©COPYRIGHT Smiths Detection Inc. 1998-2005
Wet Conditions Do not immerse the APD 2000® in water or any other liquid 9/17/2018 ©COPYRIGHT Smiths Detection Inc
28
©COPYRIGHT Smiths Detection Inc. 1998-2005
Operating the APD 2000 Preparation for Use 9/17/2018 ©COPYRIGHT Smiths Detection Inc
29
©COPYRIGHT Smiths Detection Inc. 1998-2005
Installing Batteries CAUTION Never change the batteries in a contaminated area. The battery compartment could become contaminated. Never carry the transit case into a contaminated area. The foam cushioning inside the case could become contaminated. Remove the battery cap and install the batteries as shown. 9/17/2018 ©COPYRIGHT Smiths Detection Inc
30
Installing Filtered Nozzle Standoff
CAUTION Do not touch the APD 2000® nozzle or the filter area of the Filtered Nozzle Standoff. 9/17/2018 ©COPYRIGHT Smiths Detection Inc
31
Important Information
Run the confidence test every time you power up the APD 2000®. The APD 2000® should be run at least once every month. A fully operational APD 2000® may fail a confidence test if it has not been used for some time. If this occurs and you are sure the confidence sample is not defective, let the APD 2000® run for approximately 20 minutes and repeat the test. If the unit still fails the test, let it run for an additional 20 minutes. Repeat the confidence test once more (a total of three attempts). If the unit still fails the test, return it to the manufacturer. 9/17/2018 ©COPYRIGHT Smiths Detection Inc 31
32
©COPYRIGHT Smiths Detection Inc. 1998-2005
Initial Start-UP Press POWER button Software version STNDBY CW 01 NOV :30 + READY CW 01 NOV :32 SELF TEST APD2000 APD2000 v.6.12d HORN TEST Horn test begins Self test begins Standby state Ready state 9/17/2018 ©COPYRIGHT Smiths Detection Inc
33
©COPYRIGHT Smiths Detection Inc. 1998-2005
Confidence Test WARNING The confidence sample contains chemicals that may irritate the eyes mucous membranes, and upper respiratory tract. Make sure you are in a well ventilated area and avoid prolonged breathing of the confidence sample vapor. Do not use the confidence sample if it is cracked or broken. 9/17/2018 ©COPYRIGHT Smiths Detection Inc
34
Confidence Test (Continued)
READY IRRT READY TEST READY CWVX READY CW NOTE Do not hold the confidence sample to the nozzle for more than 1 second. 9/17/2018 ©COPYRIGHT Smiths Detection Inc
35
Confidence Test (Continued)
Verify display and audio alarm READY TEST + 01 NOV :45 ALARM TEST + SIM H ALARM TEST SIM H ALARM TEST - SIM H – – + + To silence alarm, press SELECT key Verify backflush READY TEST 9/17/2018 ©COPYRIGHT Smiths Detection Inc
36
Confidence Test (Continued)
WARNING The confidence sample contains chemicals that may irritate the eyes mucous membranes, and upper respiratory tract. Make sure you are in a well ventilated area and avoid prolonged breathing of the confidence sample vapor. Do not use the confidence sample if it is cracked or broken. 9/17/2018 ©COPYRIGHT Smiths Detection Inc
37
Confidence Test (Continued)
Verify display and audio alarm ALARM TEST + SIM G ALARM TEST SIM G READY TEST + 01 NOV :45 READY CW 01 NOV :45 ALARM TEST - SIM G – – + + To silence alarm, press SELECT key Verify backflush READY TEST Return to CW Mode 9/17/2018 ©COPYRIGHT Smiths Detection Inc
38
©COPYRIGHT Smiths Detection Inc. 1998-2005
AUTO CAL NOTE After the APD 2000® has been running for a while, it may occasionally go into AUTO CAL. This means that the unit is going through a renormalization process. The unit will return to READY and be ready to continue operation within 30 seconds without operator intervention. READY CW 01 NOV :32 AUTO CAL 01 NOV :32 + 9/17/2018 ©COPYRIGHT Smiths Detection Inc
39
©COPYRIGHT Smiths Detection Inc. 1998-2005
Operating the APD 2000 General Use 9/17/2018 ©COPYRIGHT Smiths Detection Inc
40
©COPYRIGHT Smiths Detection Inc. 1998-2005
General Use The APD 2000® is suitable for monitoring: Environments Personnel Surfaces Measures agent / irritant concentration at the nozzle 9/17/2018 ©COPYRIGHT Smiths Detection Inc
41
©COPYRIGHT Smiths Detection Inc. 1998-2005
Changing Agent Modes Press MODE key to change agents READY CWVX + 01 NOV :30 READY CW 01 NOV :30 READY I RRT 01 NOV :30 CW (chemical warfare) CWVX (agent VX) IRRT (irritant) 9/17/2018 ©COPYRIGHT Smiths Detection Inc
42
©COPYRIGHT Smiths Detection Inc. 1998-2005
Monitor Mode Monitor is the default operating mode ALARM CW BLST H ALARM CW BLST H ALARM CW BLST H ALARM CW BLST H READY CW 01 NOV :40 – – + + Ready state Alarm state Silence alarm by pressing SELECT key Concentration update High concentration alarm state 9/17/2018 ©COPYRIGHT Smiths Detection Inc
43
©COPYRIGHT Smiths Detection Inc. 1998-2005
Detect Mode Ready state ALARM CW BLST ALARM CW BLST H ALARM CW BLST H READY CW 01 NOV :40 ALARM CW BLST H Alarm state + – – + Silence alarm by pressing SELECT key Automatic backflush 9/17/2018 ©COPYRIGHT Smiths Detection Inc
44
Relative Concentration
High ALARM CW BLST H ALARM CW BLST H ALARM CW BLST H READY CW 01 NOV :40 Medium Low Below alarm threshold 9/17/2018 ©COPYRIGHT Smiths Detection Inc
45
Gamma Radiation Detection
Ready state ALARM RAD R 13.5mr/h 27.5mr ALARM CW R BLST H ALARM RAD R 13.5mr/h 27.5mr ALARM CW R BLST H ALARM RAD R 13.5mr/h 27.5mr ALARM RAD R 13.5mr/h 27.5mr ALARM RAD R 13.5mr/h 27.5mr READY CW R 01 NOV :45 R Alarm state 13.5mr/h 27.5mr Silence alarm by pressing SELECT key Radiation level Cycle between CW and Rad alarms 9/17/2018 ©COPYRIGHT Smiths Detection Inc
46
Radiation Detection (Continued)
AUX key toggles RAD capability on and off READY CW 01 NOV :50 READY CW R 01 NOV :50 READY CW 01 NOV :50 READY CW R 01 NOV :50 9/17/2018 ©COPYRIGHT Smiths Detection Inc
47
©COPYRIGHT Smiths Detection Inc. 1998-2005
Operating the APD 2000 Shutdown 9/17/2018 ©COPYRIGHT Smiths Detection Inc
48
©COPYRIGHT Smiths Detection Inc. 1998-2005
Shutdown WARNING An APD 2000® contaminated by CW agents or radiation can cause death or injury. If you suspect the APD 2000® has been contaminated, do not perform SHUTDOWN. Decontaminate the APD 2000® instead. CAUTION Do not remove power from the APD 2000® while it is in alarm or clear down following agent or simulant detection. Wait until it has completely cleared down (indicated by the word READY on the display). Switching the unit off at this time could extend the warm-up time on future use. 9/17/2018 ©COPYRIGHT Smiths Detection Inc
49
©COPYRIGHT Smiths Detection Inc. 1998-2005
Shutdown (Continued) Press POWER key to shut down POWER DOWN . . . READY CW 01 NOV :50 9/17/2018 ©COPYRIGHT Smiths Detection Inc
50
©COPYRIGHT Smiths Detection Inc. 1998-2005
Shutdown (Continued) Remove filter Replace nozzle cap 9/17/2018 ©COPYRIGHT Smiths Detection Inc
51
©COPYRIGHT Smiths Detection Inc. 1998-2005
Shutdown (Continued) Remove batteries 9/17/2018 ©COPYRIGHT Smiths Detection Inc
52
©COPYRIGHT Smiths Detection Inc. 1998-2005
Shutdown (Continued) 9/17/2018 ©COPYRIGHT Smiths Detection Inc
53
©COPYRIGHT Smiths Detection Inc. 1998-2005
Operating the APD 2000 Decontamination 9/17/2018 ©COPYRIGHT Smiths Detection Inc
54
©COPYRIGHT Smiths Detection Inc. 1998-2005
Radiological Decon Press POWER key to shut down POWER DOWN . . . ALARM RAD R 13.5mr/h 27.5mr 9/17/2018 ©COPYRIGHT Smiths Detection Inc
55
Radiological Decon (Continued)
Brush, Wipe, or Vacuum Contamination from Equipment Control runoff as contaminated waste 9/17/2018 ©COPYRIGHT Smiths Detection Inc
56
Biological and Chemical Decon
CAUTION Do not decontaminate the APD 2000® or its accessories with M258A1 or M280 decontamination kits. These kits may cause false positives and temporarily render the APD 2000® inoperative. Decontaminate NBC gloves with hot soapy water or M291 Skin Decontamination Kit. Limit your work area to avoid spreading contamination. 9/17/2018 ©COPYRIGHT Smiths Detection Inc
57
Biological and Chemical Decon (Continued)
Remove filter Replace nozzle cap 9/17/2018 ©COPYRIGHT Smiths Detection Inc
58
Biological and Chemical Decon (Continued)
Remove shoulder strap from APD 2000® DO NOT immerse the APD 2000® in water or any other liquid Decontaminate APD 2000® and confidence sample with cloth soaked in hot soapy water Check decontamination with M256-series detector kit, M8/M9 detector paper, or another APD 2000® Repeat Decon until detector and confidence sample are clean 9/17/2018 ©COPYRIGHT Smiths Detection Inc
59
Biological and Chemical Decon (Continued)
READY CW + 01 NOV :53 STNDBY CW 01 NOV :52 + – – + Press POWER key Standby CW Ready CW 9/17/2018 ©COPYRIGHT Smiths Detection Inc
60
Biological and Chemical Decon (Continued)
Immerse shoulder strap in hot soapy water Rinse shoulder strap thoroughly and let air dry Check decon with M256-series detector kit, M8/M9 paper, or APD 2000® 9/17/2018 ©COPYRIGHT Smiths Detection Inc
61
Biological and Chemical Decon (Continued)
Check filter nozzle standoff package for contamination Discard as contaminated waste 9/17/2018 ©COPYRIGHT Smiths Detection Inc
62
Biological and Chemical Decon (Continued)
Remove batteries 9/17/2018 ©COPYRIGHT Smiths Detection Inc
63
Biological and Chemical Decon (Continued)
9/17/2018 ©COPYRIGHT Smiths Detection Inc
64
©COPYRIGHT Smiths Detection Inc. 1998-2005
Advanced Features APD 2000® Menu Tree 9/17/2018 ©COPYRIGHT Smiths Detection Inc
65
©COPYRIGHT Smiths Detection Inc. 1998-2005
APD 2000 Menu Tree 9/17/2018 ©COPYRIGHT Smiths Detection Inc
66
Selecting Menu Options
READY CW OPER: DETECT READY CW OPER: MONITOR READY CW 01 NOV :45 READY CW APD 2000 v6.12d READY CW OPERATING MODE: READY CW SERVICE: L READY CW LOG MODE: READY CW 01 NOV :42 READY CW ALARM MODE: READY CW HORN MODE: READY CW SET DATE/TI ME READY CW DISPLAY MODE: READY CW COMM MODE: READY CW (EXIT MENU) READY CW OPERATING MODE: 9/17/2018 ©COPYRIGHT Smiths Detection Inc
67
©COPYRIGHT Smiths Detection Inc. 1998-2005
Operating Mode The APD 2000® has two Operating modes READY CW (EXIT MENU) READY CW 01 NOV :42 READY CW OPERATING MODE: READY CW OPER: DETECT READY CW OPER: MONITOR READY CW 01 NOV :45 MONITOR - Provides continuous alarm concentration updates. DETECT - Operates as a point sample detector. (EXIT MENU) - Exits the menus and returns to the current state. 9/17/2018 ©COPYRIGHT Smiths Detection Inc
68
©COPYRIGHT Smiths Detection Inc. 1998-2005
Alarm Mode The APD 2000® provides three alarm options in DETECT MODE. READY CW ALARM: 5-MIN READY CW ALARM: DURATION READY CW ALARM: CONTIN READY CW 01 NOV :45 READY CW (EXIT MENU) READY CW ALARM MODE: DURATION – APD 2000® remains in alarm until clear down is complete. 5-MIN – APD 2000® remains in alarm for 5 minutes. CONTIN – APD 2000® remains in alarm until the horn is silenced by pressing the SELECT key. (EXIT MENU) 9/17/2018 ©COPYRIGHT Smiths Detection Inc
69
©COPYRIGHT Smiths Detection Inc. 1998-2005
Comm Mode The APD 2000® has two communication options. READY CW COMM: LOCAL READY CW COMM MODE: READY CW COMM: MAI NTENANCE READY CW 01 NOV :45 READY CW (EXIT MENU) MAINTENANCE - Provides an interface through the COMM port to a PC. The unit responds to commands. COMM port LOCAL - Provides an interface through the COMM port to a PC. The unit sends an ASCII status record. (EXIT MENU) 9/17/2018 ©COPYRIGHT Smiths Detection Inc
70
©COPYRIGHT Smiths Detection Inc. 1998-2005
Display Mode There are three Display options. AGENT - Shows class, name, and relative concentration. READY I RRT DISPLAY: CASES ALARM I RRT I RRT P READY CW DISPLAY MODE: ALARM CW BLST ALARM CW NERV GB READY CW (EXIT MENU) READY CW 01 NOV :50 READY CW DISPLAY: AGENT READY CW DISPLAY: CLASS NERV alarm 1 0 1 CLASS - Shows class and relative concentration. BLST (blister) alarm CASES - Shows class, name, and relative concentration and numeric code. IRRT (irritant) alarm (EXIT MENU) 9/17/2018 ©COPYRIGHT Smiths Detection Inc
71
©COPYRIGHT Smiths Detection Inc. 1998-2005
Horn Mode Two options are available for the horn. READY CW HORN: ENABLED READY CW HORN: DISABLED READY CW HORN MODE: READY CW 01 NOV :52 READY CW (EXIT MENU) ENABLED – Horn will sound when agent is detected. DISABLED – Horn will not sound when agent is detected. (EXIT MENU) 9/17/2018 ©COPYRIGHT Smiths Detection Inc
72
©COPYRIGHT Smiths Detection Inc. 1998-2005
Log Mode Two options are available for the automatic storing of data into the data log memory. READY CW LOG: ENABLED L READY CW LOG: DISABLED READY CW LOG MODE: L READY CW 01 NOV :52 READY CW (EXIT MENU) ENABLED – Data logging is enabled. DISABLED – Data logging is disabled. (EXIT MENU) 9/17/2018 ©COPYRIGHT Smiths Detection Inc
73
©COPYRIGHT Smiths Detection Inc. 1998-2005
Log Mode (Continued) Data logging capability READY CW R 01 NOV :52 L L 24 25 Press EVENT key to assign an event number 9/17/2018 ©COPYRIGHT Smiths Detection Inc
74
©COPYRIGHT Smiths Detection Inc. 1998-2005
Service Mode The APD 2000® has two service options. READY CW (EXIT MENU) READY CW POL DISP: DISABLE READY CW POL DIS: ENABLED READY CW TEST MODE: READY CW TEST: DISABLE READY CW POL DISPLAY: READY CW TEST: ENABLED READY CW 01 NOV :52 READY CW SERVICE: POL DISPLAY - Allows you to enable/disable the polarity indicator (+ -) on the display. TEST MODE - Provides an alternate means of putting the APD 2000® into TEST mode for the confidence test. (EXIT MENU) 9/17/2018 ©COPYRIGHT Smiths Detection Inc
75
©COPYRIGHT Smiths Detection Inc. 1998-2005
Set Date/Time This option allows you to set the clock on the APD 2000® SET YEAR SET HOUR 25 JUL :57 SET HOUR 25 JUL :57 SET HOUR 25 JUL :57 SET DAY 25 JUL :57 SET MINUTES + 25 JUL :37 SET MINUTES + 25 JUL :35 SET HOUR 25 JUL :57 SET MINUTES + 25 JUL :37 SET DAY 21 JUL :57 SET MINUTES + 25 JUL :57 SET DAY 21 JUL :57 SET YEAR 01 NOV :56 READY CW 01 NOV :56 READY CW 25 JUL :35 SET YEAR 01 NOV :56 READY CW SET DATE/TI ME SET YEAR 01 NOV :56 SET MONTH 01 JUL :57 SET DAY 01 JUL :57 SET MONTH 01 NOV :57 SET MONTH SET DAY SET HOUR SET MINUTES 9/17/2018 ©COPYRIGHT Smiths Detection Inc
76
©COPYRIGHT Smiths Detection Inc. 1998-2005
APD v6.xx Current version of APD 2000® operating software. READY CW (EXIT MENU) READY CW 25 JUL :35 READY CW DOWNLOAD NEW SW READY CW APD 2000 v6 .12d DOWNLOAD NEW SW – Allows the software to be upgraded. Return the APD 2000® to the manufacturer for upgrades. (EXIT MENU) 9/17/2018 ©COPYRIGHT Smiths Detection Inc
77
Advanced Features (Continued)
Auxiliary Functions 9/17/2018 ©COPYRIGHT Smiths Detection Inc
78
©COPYRIGHT Smiths Detection Inc. 1998-2005
AUX Key READY CW 25 JUL :36 R Press AUX key to toggle RAD indicator 9/17/2018 ©COPYRIGHT Smiths Detection Inc
79
Maintenance and Troubleshooting
Malfunctions and Service 9/17/2018 ©COPYRIGHT Smiths Detection Inc
80
©COPYRIGHT Smiths Detection Inc. 1998-2005
Error Messages 9/17/2018 ©COPYRIGHT Smiths Detection Inc
81
Error Messages (Continued)
9/17/2018 ©COPYRIGHT Smiths Detection Inc
82
Error Messages (Continued)
9/17/2018 ©COPYRIGHT Smiths Detection Inc
83
Error Messages (Continued)
9/17/2018 ©COPYRIGHT Smiths Detection Inc
84
©COPYRIGHT Smiths Detection Inc. 1998-2005
Other Malfunctions 9/17/2018 ©COPYRIGHT Smiths Detection Inc
85
Other Malfunctions (Continued)
9/17/2018 ©COPYRIGHT Smiths Detection Inc
86
©COPYRIGHT Smiths Detection Inc. 1998-2005
Servicing the APD 2000 Operator Service Takes 5 minutes per 24 hours of operation Change batteries Change filtered nozzle standoff 9/17/2018 ©COPYRIGHT Smiths Detection Inc
87
Scheduled Maintenance
Smiths Detection recognizes that our responsibility to our customers does not end the day we complete the sale. A service agreement provides a cost effective solution to assure proper operation of the APD 2000®. The service agreement also allows you to budget one fixed expense through the agreement period. Unplanned maintenance expenses are minimized or eliminated dependent on the type of coverage selected. It is with this in mind that we offer the following service agreement options: 9/17/2018 ©COPYRIGHT Smiths Detection Inc
88
Scheduled Maintenance (Continued)
Maintenance Agreement: Includes repair or replacement of components damaged through normal use of the systems One yearly preventive maintenance checkup to include replacement of charcoal filters and sieve packs, ammonia source replenishment, software update, radiation wipe test, and functional certification testing Equipment maintenance will be completed within 5 to 10 business days of receiving the equipment All repairs and preventive maintenance procedures to be performed in Service Lab, an in-house repair depot 9/17/2018 ©COPYRIGHT Smiths Detection Inc
89
Scheduled Maintenance (Continued)
Preventative Maintenance Agreement: Includes one yearly replacement of charcoal filters and sieve packs, ammonia source replenishment, software update, radiation wipe test, and functional certification testing Preventive maintenance will be completed within 5 to 7 business days of receiving the equipment Any required equipment repairs will be charged separately 9/17/2018 ©COPYRIGHT Smiths Detection Inc
90
Service Inquiries For service inquiries please call 1-866-699-4199
or 9/17/2018 ©COPYRIGHT Smiths Detection Inc
Similar presentations