Download presentation
Presentation is loading. Please wait.
1
ISO ASIS Automation & Fueling Systems A.Ş. Copyright © 2012 All rights reserved.
2
CalibeX, is ATEX Certified for Ex d Zone 1 and Zone 0,
3D CalibeX™, Calibex is a state of art new technology which is applied for the first time in the world PCT World Patent application is done in 2007 and in patent rights are approved . The basis of the project depends on dimensional measurements which can make a world-class and very accurate tank calibration. CalibeX, is ATEX Certified for Ex d Zone 1 and Zone 0, Asis Automation & Fueling Systems A.Ş. Copyright © 2012 All rights reserved
3
CalibeX™ Certificate (ISO 12917- 2 )
Calibration Standard ISO Petroleum and liquid petroleum products -- Calibration of horizontal cylindrical tanks -- Part 2: Internal electro-optical distance-ranging method Abstract ISO :2002 specifies a method for the calibration of horizontal cylindrical tanks having diameters greater than 2 m by means of internal measurements using an electro-optical distance-ranging instrument, and for the subsequent compilation of tank-capacity tables. This method is known as the internal electro-optical distance-ranging (EODR) method. ISO :2002 is applicable to tanks inclined by up to 10 % from the horizontal, provided a correction is applied for the measured tilt. Asis Automation & Fueling Systems A.Ş. Copyright © 2012 All rights reserved
4
CalibeX™ System Components
3D CalibeX system is based on 5 main elements. Calibex Laser Scanner Unit CalibeX Measurement Panel CalibeX Connection apparatus CalibeX Center Center Analysis Applications OATS CalibeX servers and applications Asis Automation & Fueling Systems A.Ş. Copyright © 2012 All rights reserved
5
CalibeX™ Application Basis
CalibeX Scanner ; Finds all the dimensions of the tank's interior as 3D spatial points. Finds the slope of the tank, (Angle) Finds the direction and position of the tank, Finds the diameter of the tank, (R) Finds Interior dimensions of the tank (H, L) Finds the diameter of the tank dome, (Rd) Makes the mathematical model of the tank. (f (x) Generates calibration data through 3D modeling and sophisticated mathematical algorithms. Asis Automation & Fueling Systems A.Ş. Copyright © 2012 All rights reserved
6
CalibeX™ Application Basis
Side view 3D Modelling Front view Creating Table Asis Automation & Fueling Systems A.Ş. Copyright © 2012 All rights reserved
7
FIELD Application of CalibeX™
Asis Automation & Fueling Systems A.Ş. Copyright © 2012 All rights reserved
8
FIELD Application of CalibeX™
Asis Automation & Fueling Systems A.Ş. Copyright © 2012 All rights reserved
9
CalibeX™ Scanning Results
Horizontal cross section model of the UST (Side View) Asis Automation & Fueling Systems A.Ş. Copyright © 2012 All rights reserved
10
CalibeX™ Scanning Results
Vertical cross section model of the UST (Section View) Asis Automation & Fueling Systems A.Ş. Copyright © 2012 All rights reserved
11
CalibeX™ Measuring Accuracy
Calibex creates highly reliable results in both lab tests and field tests. In Laboratory and field testing platform the maximum possible sensitivity level available today is not better than % 0.2 (two per thousand) for detection of the volumetric uncertainty. All lab and field tests of Calibex the accuracy results are between % 0.2 and % 0.9 These are guarantied uncertainty values. (Information reported in writing by TUBITAK UME.) Asis Automation & Fueling Systems A.Ş. Copyright © 2012 All rights reserved
12
CalibeX™ Implementation Results (Example)
Deviation % 0.8 Deviation % 0.5 Asis Automation & Fueling Systems A.Ş. Copyright © 2012 All rights reserved
13
Calibration Data Asis Automation & Fueling Systems A.Ş. Copyright © 2012 All rights reserved
14
CalibeX™ Field Application Requirements
In the event of there is fuel in the tank , the diameter the fuel level should not exceed 30 % of total measuring span. In other words, in 2,000 mm (2 m) diameter tank max. Fuel level should be 300 mm which approximately corresponds to litres of fuel in the tank. This level must be provided. The system, should be mounted on the existing level probe provision on the tank cover. In this case if there is a level probe on the tank cover, it should be dismantled during laser scanning and re-installed after the process. If there is no level sensor in the tank the scanning process should be done on the level measurement provision for the best result. The point where the level is measured manually or automatically and calibration should be same for accuracy. Asis Automation & Fueling Systems A.Ş. Copyright © 2012 All rights reserved
15
CalibeX™ Manhole Application Requirements
CalibeX requires minimum of 15 cm in a circular area , 50 cm height above 2 “ Tank provision the free area for installation. If the submersible pumps, pipes, connections, etc in the ManHole does not allow for such space then, some of the equipments on the cover should be dismanteled for a period of scanning (likely %10 of all tanks ) Asis Automation & Fueling Systems A.Ş. Copyright © 2012 All rights reserved
16
CalibeX™ ATEX Certificate
Asis Automation & Fueling Systems A.Ş. Copyright © 2012 All rights reserved
17
CalibeX™ Technology CalibeX project has been carried out in 4 years with over 10 side and supporting developments with almost 3.2 million Euros of R&D budget. The areas of expertise used in development of CalibeX Technology are listed below : 1. Electronic Engineering : Microprocessor controlled, stepper motor, electronic and power circuits are designed together with the laser technology 2.Software Design and Engineering : Special 3D analysis software development for Calibration data acquisition and analysis , embeded software design for controllers and central management Server Software 3.Mechatronics and Electromechanical Design Engineering: Integration and combination of electronics, software and mechanical parts. 4.Mechanical Design Engineering: 3D CalibeX mechanical parts, such as housing and the gears in Ex-proof concept 5. Mathematical and Physics Engineering: Calibration measurements generated during the design of algorithms, mathematical-physical rules and calculations used. 6.System Integration Test Engineering: Determination of properties of the system, used for testing and integration is our specialty. All in all fields of expertise in the development of this project are sourced within our company. Asis Automation & Fueling Systems A.Ş. Copyright © 2012 All rights reserved
18
CalibeX™ References 6.596 TANKS 414 TANKS 300 TANKS 685 TANKS
Asis Automation & Fueling Systems A.Ş. Copyright © 2012 All rights reserved
19
Thank you ... Baypore Private Limited 1 Soon Lee Street
04-41 Pioneer Centre Singapore Hotline: Asis Automation & Fueling Systems A.Ş. Copyright © 2012 All rights reserved
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.