Presentation is loading. Please wait.

Presentation is loading. Please wait.

HP StorageWorks P2000 G3 SAS Modular Smart Array

Similar presentations


Presentation on theme: "HP StorageWorks P2000 G3 SAS Modular Smart Array"— Presentation transcript:

1 HP StorageWorks P2000 G3 SAS Modular Smart Array

2 Agenda MSA 2000 Series (G2) – Product Family Introduction P2000 G3 SAS
Array Installation Back End and Cabling Host Connectivity Web Based Interface Troubleshooting Upgrading Firmware Q & A

3 Product Family Introduction
MSA 2000 Series (G2) Product Family Introduction

4 MSA 2000 (G2) Product Description
Single-and Dual-controller hardware configurations 2U, efficient packaging Fully redundant Hot-swap components DAS and SAN connectivity Up to four Direct-connect hosts FC, iSCSI and SAS host interfaces Fibre Channel Arbitrated Loop and Switch protocols Support from 2 to 99 disks LFF drives 500GB, 750GB, and 1TB 7200 RPM SATA drive 146GB, 300GB, and 450GB 15K RPM SAS drive SFF drives 36GB (10K), 72GB and 146GB (10K and 15K), 300GB (10K) SAS drives 60GB, 250GB, 120GB 5.4K RPM SATA drives Freely mix in any quantities, any locations RAID 0, 1, 3, 5, 6,10, 50 data protection Hot spare support (Local and Global) Embedded Management software is OS platform independent Owned LUN implementation, LUNs are not universally accessible The MSA 2000 G2 series also supports single port drives for use in the MSA70 enclosure.

5 MSA 2000 (G2) Family 1GB Cache Up to 60 LFF or 99 SFF SAS and/or SATA drives 2000fc G2 4 Gb FC Host interface (2 ports per controller) 2000sa G2 3 Gb SAS Host interface (4 ports per controller) 2000i G2 1Gb iSCSI Host interface (2 ports per controller)

6 HP StorageWorks array portfolio
XP EVA XP24000 2000 Family Entry-level SANs P2000 G3 SAS P2000 G3 FC MSA2000i G2 P4000 SAN XP20000 The StorageWorks division offers a complete portfolio of disk array systems, ranging from the entry level Modular Storage Array family, to the mid-range Enterprise Virtual Array and the XP family on the high end. XP DISK ARRAYS The XP disk arrays are large enterprise-class storage systems designed for organizations that simply cannot afford any downtime or tolerate any data loss. With the XP's ability to allocate capacity when needed, virtualizes a variety of disk arrays, partition storage resources, and connect to many hosts, IT managers can now consolidate their data centers and operate them more efficiently. Combined with HP’s disaster proof solutions, the XP disk arrays provide unfailing data protection when needed most. EVA DISK ARRAYS The HP StorageWorks 4100/4400/6100/8100 Enterprise Virtual Arrays offer customers in the mid-range to enterprise market place leading high performance, high capacity and high availability "virtual" array storage solutions. P2000 & MSA2000 DISK ARRAYS The HP StorageWorks 2000-series family selection of SAN devices features the very latest in efficient consolidation, functionality and technology at very affordable prices. The ideal customers needing to consolidate their storage include smaller companies with tight budgets and limited IT expertise, or larger companies that have perhaps hundreds of smaller departments and remote locations. Always-on availability Data center consolidation + disaster recovery Large-scale Oracle/SAP applications HP-UX, Windows, + 20 more, including NonStop & mainframe Consolidation and Performance Outstanding TCO FC & iSCSI host ports FC & FATA HDD Storage consolidation + disaster recovery Simplification through virtualization HP-UX, Windows, Linux, VMware + more Mid Market MS, Oracle & SAP applications Scalable, Clustered IP SAN iSCSI, 10GbE optional Scalable Performance SATA & SAS HDD Cost effective high availability VMware, Citrix, Hyper-V, Windows, Linux Low cost consolidation 6Gb SAS 8Gb FC & 8Gb FC/iSCSI 1GbE iSCSI, and 3Gb SAS SAS & SATA together Controller-based snapshot/clone Remote Snap (G3) Windows, Linux, HP-UX, Hyper-V, VMware + more WEB, Exchange, SQL HP Confidential Business Continuity and Availability 6

7 P2000 G3 SAS

8 P2000 G3 SAS Modular Storage Array
HP next generation entry-level array, follow-on product to the MSA2000sa G2, featuring the latest in SAS 6Gb technology, SAS controllers, increased scalability 2U24 2U12

9 P2000 G3 SAS Modular Smart Array overview
What’s new for G3? Increased scalability over G2 series 50 percent increase in max SFF drives to 149 60 percent increase in max LFF drives to 96 Single or dual 6Gb SAS controllers (four ports per controller) 64 snapshot capability standard (optional 512) Volume Copy standard 6Gbps SAS backend Drive spin-down Performance statistics in CLI The MSA2000 G2 did not have snapshot capability as a standard feature, and a max of only 256 snaps. Volume Copy was also optional.

10 P2000 G3 SAS Modular Smart Array overview
High-performance 6Gb SAS Four 6Gb SAS host ports per controller 64 snapshot capability standard (optional 512) Volume Copy enabled Deploy single or dual controllers depending on high-availability (HA) and budgetary requirements Controller View

11 P2000 G3 SAS Modular Smart array
P2000 G3 SAS Array Features 6Gb SAS controller (4 ports per controller) 2GB Cache 6Gb SAS back end Up to 96 (LFF) or 149 (SFF) SAS and/or SATA drives 512 LUNs max 16TB max LUN size 64 hosts max Queue depth 512 per port Non-disruptive controller FW update (requires dual controller configuration) Non-disruptive FW update may cause I/O performance to decline during the update operation.

12 P2000 G3 SAS Modular Smart array
Target market Entry-level customers Companies with small IT budgets or limited IT expertise Larger companies with departmental or remote requirements

13 P2000 G3 SAS Modular Smart array features
Highly efficient consolidation Sharing of storage geared to departmental and SMB requirements Grows as storage demands increase – up to 57.6 TB SAS or 192 TB SATA Supports from 64 host WWN Flexible Deploy single or dual controllers depending on high-availability (HA) and budgetary requirements Select LFF and SFF drives and enclosures, high-availability levels Enterprise-class SAS, SAS Midline, or archival-class SATA drives as the HA need and budget dictate (mixable) Cost efficient Build either single or dual controller array models using SAS, SAS MDL, or SATA MDL drives 64 snapshot and clone capability standard for increased data protection Easy to manage and service

14 Shipping 3G drives also supported
P2000 G3 Supported drives Maximum number of drives 149 Small Form Factor (SFF) drives 96 Large Form Factor (LFF) drives Drive types P GB 6G 15K LFF DP ENT SAS P GB 6G 15K LFF DP ENT SAS P GB 6G 15K LFF DP ENT SAS P2000 2TB 3G 7.2K LFF MDL SATA 72GB 6G 15K SFF DP SAS 146GB 6G 10K SFF DP SAS 300GB 6G 10K SFF DP SAS 146GB 6G 15K SFF DP SAS 500GB 6G 7.2K SFF DP MDL SAS Maximum capacity 192TB Shipping 3G drives also supported

15 P2000 G3 SAS MSA skus Volume shipments available June 21.
New Product Introduction for Employees and Channel Partners P2000 G3 SAS MSA skus Volume shipments available June 21. CTO available on all skus by June 24 P2000 G3 FC MSA Controllers & Controller-less Chassis HP StorageWorks P2000 G3 SAS Modular Smart Array Controller (four 6Gb SAS ports) AW592A HP StorageWorks P2000 Modular Smart Array 3.5-in Drive Bay Chassis (LFF) (Will accept one or two controllers or Disk Enclosure I/O modules) AP838A HP StorageWorks P2000 Modular Smart Array 2.5-in Drive Bay Chassis (SFF) (Will accept one or two controllers, not I/O modules) AP839A Disk Enclosures HP StorageWorks P2000 Dual I/O LFF Drive Enclosure, twelve 3.5” drive bays (w/ two.5m mini-SAS to mini-SAS cables. Used with single or dual controller LFF or SFF array head) AP843A HP StorageWorks P2000 LFF Drive Enclosure I/O Module (no cable included. Designed for use with blank LFF chassis AP838A) AJ844A HP StorageWorks D2700 SFF Disk Enclosure, twenty-five 2.5” drive bays (w/ two .5m mini-SAS to mini-SAS cables. Used with single or dual controller LFF or SFF array head) AJ941A Configured Units HP StorageWorks P2000 G3 MSA SAS Dual Controller LFF Modular Smart Array System AW593A HP StorageWorks P2000 G3 MSA SAS Dual Controller SFF Modular Smart Array System AW594A Controller-less Chassis: DC-powered units HP StorageWorks P2000 DC-power LFF Chassis (can add one or two P2000 G3 FC controllers or P2000 JBOD I/O modules) AP840A HP StorageWorks P2000 DC-power SFF Chassis (can add one or two P2000 G3 FC controllers. No P2000 JBOD I/O module support) AP841A CONTROLLER CHASSIS CHASSIS JBOD IO Module JBOD DUAL CONTROLLER ARRAYS DC-powered CHASSIS 15 HP Product Announcement – HP Restricted

16 Array Installation

17 Installation Overview
Unpack the array Obtain the necessary accessories and equipment Mount the controller and expansion trays in a rack or cabinet Connect the AC power to the two power modules Perform initial power-up Connect the management hosts to the controller tray Connect the data hosts to the controller tray Use the WBI or CLI to set the Ethernet IP address, netmask, and gateway address, for each controller module. (DHCP mode by default, if no DHCP server, controller A IP is , controller B is ) Use WBI or the CLI to set the array date and time Set the basic array configuration parameters Plan and implement your storage configuration The order of these steps differs slightly from the steps outlined in the User Guide. The User Guide indicates to set the IP address before connecting data and management hosts. In an entry level implementation however, the user may not have extra hosts available for the configuration steps, so the order shown in this slide would be appropriate.

18 Connecting to a terminal emulator
Start and configure a terminal emulator, such as HyperTerminal using the following settings: Terminal Emulator Display Settings Terminal Emulation Mode - VT-100 or ANSI (for color support) Font - Terminal Translations - None Columns - 80 Terminal Emulator Connection Settings Connector - COM1 (typically) Baud rate (bits/sec) - 115,200 Data bits - 8 Parity - None Stop bits - 1 Flow control - None 18

19 Connecting via USB link
There is a “Host” interface and a “Device” interface USB Port. The port labeled “Host” (USB Type A) is reserved for future use. The port labeled “CLI” (USB Type B) is used to access the unit via CLI. Certain operating systems require a device driver or special mode of operation to enable proper functioning of the USB CLI port. You can download the device driver from hp.com – download drivers and SW section for P2000 MSA storage.

20 Applying the IP Address
At the prompt (#), type the following command to set the IP address for controller A set network-parameters ip <address> netmask <netmask> gateway <gateway> controller a At the prompt (#), use the same command to set the IP address for controller B except indicate controller B by replacing the “a” at the end of the command with “b” Type the following command to verify the new IP addresses: Show network-parameters Verify Ethernet connectivity by pinging the IP addresses from a different system If you cannot your access your system for at least three minutes after changing the IP address, your network might require you to restart the Management Controller(s) using the serial CLI. When you restart a Management Controller, communication with it is temporarily lost until it successfully restarts. Type the following command to restart the management controller on both controllers: restart mc both You can now manage the storage through the web interface

21 Back end and cabling

22 P2000 G3 SAS Back End Connections
Controller module MSA2000 MSA2300 P2000 G3 SFF-8088 SFF-8470 The MSA 2300fc G2 also used the mini-SAS connectors.

23 P2000 G3 controller enclosure support
Controller enclosures support both 3Gbps and 6Gbps internal drives and expander link speeds Mixing 3Gbps and 6Gbps drive enclosures is supported, but performance can be limited if the enclosures are not cabled properly Cable the 3Gbps enclosures behind the 6Gbps enclosures Guidelines Use only supported SAS 4x cables. Mini-SAS to mini-SAS 0.5m cables are provided with the P2000 6Gb 3.5” 12–drive enclosure, D2700 6Gb drive enclosure, and MSA70 3Gb drive enclosure (one per controller) SAS to SAS 0.6m cables are provided with the MSA2000 3Gb 3.5“ 12-drive enclosure (one per I/O module) Longer cables than those supplied with the enclosure must be purchased separately. See the MSA Quick Specs for details The maximum length cable allowed in any configuration is 2m. A maximum of 8 enclosures (including the array enclosure) OR 149 drives are allowed in the array configuration For more information, see the P2000 G3 MSA System Cable Configuration Guide. The P2000 G3 and D2700 drive enclosures both support the SAS 2.0 communication protocol while the MSA70 and MSA2000 drive enclosures both support the SAS 1.1 communication protocol. As such, P2000 G3 and D2700 drive enclosures should always be cabled in front of MSA70 and MSA2000 drive enclosures.

24 Connecting drive enclosures
P2000 G3 MSA supports these four drive enclosures: HP StorageWorks P2000 6Gb 3.5” 12–drive enclosure HP StorageWorks D2700 6Gb drive enclosure HP StorageWorks MSA2000 3Gb 3.5” 12–drive enclosure HP StorageWorks MSA70 3Gb drive enclosure

25 P2000 G3 Back End Connections
Fault-tolerant example Allows any drive enclosure to fail or be removed Recommended approach to cabling Enclosure I/O modules A shaded green Enclosure I/O modules B shaded red Array The above diagram shows a P2000 G3 MSA System connected to two D2700 6Gb drive enclosures in fault-tolerant fashion. I/O modules A on the drive enclosures are shaded green. I/O modules B on the drive enclosures are shaded red. Fault-tolerant (or reverse) cabling requires that you connect P2000 G3 controller A to I/O module A of the first disk enclosure and cascade this connection on to I/O module A of the last disk enclosure (green). Likewise, you must connect P2000 G3 controller B to I/O module B of the last disk enclosure and cascade this connection on to I/O module B of the first disk enclosure (red).

26 P2000 G3 Back End Connections
Single enclosure P2000 G3 6Gb Array Single enclosure D2700 6Gb Array The above diagrams show single enclosure configurations for the P2000 G3 and D2700 enclosures respectively. In both cases, data throughput in the array performs at the 6Gbps rate, as both the controller enclosures and the drive enclosures support 6Gbps speeds.

27 P2000 G3 Back End Connections
Single enclosure MSA70 3Gb Array Single enclosure MSA2000 3Gb Array The above diagrams show single enclosure configurations for the MSA70 3Gb and MSA2000 3Gb enclosures respectively. In both cases, data throughput in the array performs at the 3Gbps rate, as the drive enclosures only support 3Gbps speeds.

28 P2000 G3 Back End Connections
Mixed-connect configuration P2000 6Gb (2) and D2700 6Gb (3) Array The above diagram shows a dual-controller P2000 G3 MSA System (1) connected to a P2000 6Gb drive enclosure (2) and D2700 6Gb drive enclosure (3). Data throughput in the array performs at the 6Gbps rate, as both the controller enclosure and the drive enclosures support 6Gbps speeds.

29 P2000 G3 Back End Connections
Mixed-connect configuration D2700 6Gb (2) and MSA2000 3Gb (3) Array The above diagram shows a dual-controller P2000 G3 MSA System (1) connected to a D2700 6Gb drive enclosure (2) and a MSA2000 3Gb 3.5” 12–drive enclosure (3). Data throughput in the array runs at the 3Gbps rate, as the MSA2000 drive enclosure supports only 3Gbps speeds.

30 P2000 G3 Back End Connections
Array All enclosure types P2000 G3 Array P2000 6Gb D2700 6Gb MSA70 3Gb MSA2000 3Gb The above diagram shows a dual-controller P2000 G3 MSA System (1) connected to a P2000 6Gb drive enclosure (2), D2700 6Gb drive enclosure (3), MSA70 3Gb drive enclosure (4), and MSA2000 3Gb 12–drive enclosure (5). Data throughput in the array runs at the 3Gbps rate, as the MSA70 and MSA2000 drive enclosures support only 3Gbps speeds.

31 P2000 G3 Back End Connections
Array Maximum drive count P2000 G3 array (1) D2700 6Gb (2-6) Max SFF configuration 149 drives The above diagram shows a P2000 G3 MSA System (1) is connected to five D2700 6Gb drive enclosures (2 through 6). Each D2700 drive enclosure contains 25 disk drives and the P2000 G3 MSA SFF controller enclosure contains 24 disk drives. Combined, the total number of disk drives in array configuration add up to the maximum 149 drives allowed. Note that the maximum number of enclosures requirement (eight) is not exceeded. Data throughput in the array performs at the 6Gbps rate, as both the controller enclosure and the drive enclosures support 6Gbps speeds.

32 P2000 G3 Back End Connections
Array Maximum enclosure count P2000 G3 array (1) P2000 6Gb (2-8) Max LFF configuration 96 drives The above diagram shows a P2000 G3 MSA System (1) is connected to seven P2000 6Gb 12–drive enclosures (2 through 8). Note that the maximum number of drives requirement (149) is not exceeded. Data throughput in the array performs at the 6Gbps rate, as both the controller enclosure and the drive enclosures support 6Gbps speeds. This configuration has 96 LFF drives.

33 P2000 G3 Back End Connections
SAS expansion cable requirements P2000 G3 controller P2000 6Gb 3.5” I/O mod Mini-SAS to Mini-SAS 0.5m D2700 6Gb I/O mod MSA Gb I/O mod SAS to Mini-SAS 0.5m, 1m, 2m * MSA 70 3Gb I/O mod SAS to Mini-SAS 0.5m * SAS to SAS 0.6m * The P2000 G3 and D2700 drive enclosures both support the SAS 2.0 communication protocol while the MSA70 and MSA2000 drive enclosures both support the SAS 1.1 communication protocol. As such, P2000 G3 and D2700 drive enclosures should always be cabled in front of MSA70 and MSA2000 drive enclosures. * Not supplied

34 Host Connectivity

35 Supported Operating Systems
Supported operating systems for connected hosts Windows Server 2003 R2 SP2, Server 2008 SP1 SP2, Server 2008 R2 (Win 7) Hyper-V Server 2008, Server 2008 R2 (Win 7), x64 only Linux RHEL 4.7, 4.8, 5.3, 5.4 SLES 10.3, 11 VMware 4.0, 4.1 Solaris 10 XEN Citrix 5.5, SLES

36 Host interfaces Interfaces Topologies Support SAS HBAs
6 Gb SAS Controller 4 ports per controller Topologies Direct connect Support SAS HBAs HP SC08Ge SAS HBA Currently shipping 3Gb SAS HBA HP SC08e 6Gb SAS HBA New 6Gb SAS HBA, launching in June Supported in most ProLiant G6 and G7 servers

37 Host Cabling Dual controller configuration with two hosts, dual path

38 Host Cabling Dual controller configuration with four hosts, dual path

39 Host Cabling Remote management
RJ-45 Ethernet cable connected to the network port on each P2000 G3 MSA controller Other end of Ethernet cable connected to a network that the management host can access (preferably same subnet)

40 Software

41 Included and optional software
HP StorageWorks MSA2000 Snapshot Software (included) Enables increased data protection by creating recovery points Snapshots are maintained as data continues to change MSA2000 snapshots are controller-based HP StorageWorks MSA2000 Volume Copy Software (included) Makes a physical copy of the data to another set of disks within the same array Volume copy may be mounted for backup, testing, data mining MSA2000 Volume Copy is controller-based No server performance impact HP StorageWorks Storage Mirroring (optional) Prevents data loss from failure, error, or disaster Provides replication and recovery of Windows and Linux data to another server

42 Upgrades

43 Upgrading existing MSA2000 arrays
P2000 G3 controllers can be used to replace controllers in MSA2000 arrays Existing MSA2000 G1 and G2 customers can upgrade their systems with P2000 G3 SAS controllers. They can retain their chassis, drives, and JBODs. The newly configured unit would take on the full personality of a G3 except that the “back-end” would be restricted to the SAS 3Gb transfer speed. P2000 G3 SAS features like increased scalability, standard snapshot and Volume Copy, and optional Remote Snap would now be characteristic of their newly upgraded array. Not only generational upgrades, but cross-protocol upgrades are also supported. For example owners of an early MSA2000i iSCSI array (G1) could upgrade with third generation P2000 G3 SAS controllers. Upgrade papers will be available on the P2000 G3 SAS web-site.

44 Warranty

45 Warranty options Standard warranty http://www.hp.com/hps/storage
3-year parts exchange, Next Business day delivery Enclosures, Hard drive, and Options carry their own warranty HP Care Pack Services are available Warranty Upgrade Options Response - Upgrade on-site response from next business day to same day 4-hour response or 6 Hour Call To Repair Coverage - Extend hours of coverage from next business day to 9 hours x 5 days to 24 hours x 7 days Duration Select duration of coverage for a period of 1, 3, 4 or 5 years Note: The warranty of the hard drive options purchased with the P2000 G3 FC product is different for SAS hard drives versus SATA hard drives. SAS hard drive options have a three year warranty and SATA hard drives options have a one year warranty. The P2000 G3 FC has been designed with customer self repairable parts to minimize repair time and provide greater flexibility in performing defective parts replacement. Please refer to HP's limited warranty Statement and parts replacement instructions for further details.

46 Customer Self Repair HP MSA warranty includes support for Customer Self Repair (CSR) Mandatory CSR parts include: Drives Controller board Power supplies

47 Q&A


Download ppt "HP StorageWorks P2000 G3 SAS Modular Smart Array"

Similar presentations


Ads by Google